CHCamilla Haahr-Raunkjær

Camilla Haahr-Raunkjær

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Camilla Haahr-Raunkjær has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Postoperative Delirium and the Association to Continuously Monitored Severe Deviations of Vital Signs at the General Ward After Major Abdominal Surgery

    by Hussein Nasser Awada, Camilla Haahr‐Raunkjær, Jesper Mølgaard, Søren Møller Rasmussen, Christian Sylvest Meyhoff, Eske Kvanner Aasvang

    Background: Delirium is the most frequent neurological complication after surgery and is associated with increased postoperative morbidity and mortality. The underlying pathophysiology is not fully understood, but is suggested to be multifactorial, including hypoperfusion and hypoxia; however, the role of deviating vital signs prior to postoperative delirium (POD) remains unclear. This study aimed to examine the association between severe physiological deviations detected by continuous wireless monitoring and the occurrence of POD within the first three postoperative days after major abdominal cancer surgery. Methods: In this prospective substudy, the primary outcome delirium was assessed daily with the validated 3D‐CAM questionnaire during the first three postoperative days following major abdominal cancer surgery, and patients were classified into three groups: POD, neurocognitive decline (NCD), and no cognitive impairment (controls). Vital signs (blood pressure, respiratory rate, heart rate, and peripheral oxygen saturation) were continuously monitored for up to 96 h postoperatively. The primary exposure was the cumulative duration of severely deviating vital signs 24 h before POD diagnosis. Secondary exposures included the frequency of sustained severe vital sign deviation episodes. Results: Of 225 patients with complete 3D‐CAM data, 22 (9.8%) developed POD, 73 (32.4%) had NCD, and 130 (57.8%) had no cognitive impairment (controls). The median cumulative duration of vital sign deviations 24 h prior to POD was not significantly different between POD patients and controls (204 min vs. 325 min, p = 0.63). Episodes of sustained tachycardia, bradycardia, and bradypnea in the 24 h prior to POD diagnosis were more frequent in POD patients compared to controls, all p < 0.001. In the 24 h after POD diagnosis, patients with POD also exhibited more frequent episodes of sustained tachypnea, desaturation, tachycardia, and hypertension than controls (all p ≤ 0.005). In NCD patients, deviations were intermediate: bradypnea and bradycardia were more frequent before, and tachycardia, hypotension, hypertension, and desaturation more frequent after the NCD assessment, compared with controls. Conclusion: Although the cumulative duration of severe vital sign deviations did not differ between POD patients and controls, episodes of sustained severe vital sign deviations were significantly more frequent in POD patients before and after POD diagnosis, suggesting a potential for earlier identification of patients at risk. Whether acting on these signals alters the incidence of delirium was not tested and requires a prospective study. Editorial Comment: In this secondary analysis of a prospectively assessed high risk surgical cohort, postoperative vital sign deviations acquired from wireless technology were analysed for possible relations to postoperative delirium development. The findings show that vital sign deviation was observed often before or after delirium development, though it is not yet clear which category or measurement of vital sign deviation would be most likely to be associated with delirium. Trial Registration: NCT03491137

  • Open Access

    Excessive Oxygen Administration in High-Risk Patients Admitted to Medical and Surgical Wards Monitored by Wireless Pulse Oximeter

    by Clara E. Mathar, Camilla Haahr-Raunkjær, Mikkel Elvekjær, Ying Gu, Claire P. Holm, Michael P. Achiam, Lars N. Jorgensen, Eske K. Aasvang, Christian S. Meyhoff

    The monitoring of oxygen therapy when patients are admitted to medical and surgical wards could be important because exposure to excessive oxygen administration (EOA) may have fatal consequences. We aimed to investigate the association between EOA, monitored by wireless pulse oximeter, and nonfatal serious adverse events (SAEs) and mortality within 30 days. We included patients in the Capital Region of Copenhagen between 2017 and 2018. Patients were hospitalized due to acute exacerbation of chronic obstructive pulmonary disease (AECOPD) or after major elective abdominal cancer surgery, and all were treated with oxygen supply. Patients were divided into groups by their exposure to EOA: no exposure, exposure for 1–59 min or exposure over 60 min. The primary outcome was SAEs or mortality within 30 days. We retrieved data from 567 patients for a total of 43,833 h, of whom, 63% were not exposed to EOA, 26% had EOA for 1–59 min and 11% had EOA for ≥60 min. Nonfatal SAEs or mortality within 30 days developed in 24%, 12% and 22%, respectively, and the adjusted odds ratio for this was 0.98 (95% CI, 0.96–1.01) for every 10 min. increase in EOA, without any subgroup effects. In conclusion, we did not observe higher frequencies of nonfatal SAEs or mortality within 30 days in patients exposed to excessive oxygen administration.


  • Open Access

    Quantifying physiological stability in the general ward using continuous vital signs monitoring: the circadian kernel density estimator

    by Søren S. Rasmussen, Katja K. Grønbæk, Jesper Mølgaard, Camilla Haahr-Raunkjær, Christian S. Meyhoff, Eske K. Aasvang, Helge B. D. Sørensen

    Technological advances seen in recent years have introduced the possibility of changing the way hospitalized patients are monitored by abolishing the traditional track-and-trigger systems and implementing continuous monitoring using wearable biosensors. However, this new monitoring paradigm raise demand for novel ways of analyzing the data streams in real time. The aim of this study was to design a stability index using kernel density estimation (KDE) fitted to observations of physiological stability incorporating the patients’ circadian rhythm. Continuous vital sign data was obtained from two observational studies with 491 postoperative patients and 200 patients with acute exacerbation of chronic obstructive pulmonary disease. We defined physiological stability as the last 24 h prior to discharge. We evaluated the model against periods of eight hours prior to events defined either as severe adverse events (SAE) or as a total score in the early warning score (EWS) protocol of ≥ 6, ≥ 8, or ≥ 10. The results found good discriminative properties between stable physiology and EWS-events (area under the receiver operating characteristics curve (AUROC): 0.772–0.993), but lower for the SAEs (AUROC: 0.594–0.611). The time of early warning for the EWS events were 2.8–5.5 h and 2.5 h for the SAEs. The results showed that for severe deviations in the vital signs, the circadian KDE model can alert multiple hours prior to deviations being noticed by the staff. Furthermore, the model shows good generalizability to another cohort and could be a simple way of continuously assessing patient deterioration in the general ward.


  • Agreement between standard and continuous wireless vital sign measurements after major abdominal surgery: a clinical comparison study

    by Camilla Haahr-Raunkjaer, Magnus Skovbye, Søren M Rasmussen, Mikkel Elvekjaer, Helge B D Sørensen, Christian S Meyhoff, Eske K Aasvang

    Objective . Continuous wireless monitoring outside the post-anesthesia or intensive care units may enable early detection of patient deterioration, but good accuracy of measurements is required. We aimed to assess the agreement between vital signs recorded by standard and novel wireless devices in postoperative patients. Approach . In 20 patients admitted to the post-anesthesia care unit, we compared heart rate (HR), respiratory rate (RR), peripheral oxygen saturation (SpO 2 ), and systolic and diastolic blood pressure (SBP and DBP) as paired data. The primary outcome measure was the agreement between standard wired and wireless monitoring, assessed by mean bias and 95% limits of agreement (LoA). LoA was considered acceptable for HR and PR, if within ±5 beats min −1 (bpm), while RR, SpO2, and BP were deemed acceptable if within ±3 breaths min −1 (brpm), ±3%-points, and ±10 mmHg, respectively. Main results. The mean bias between standard versus wireless monitoring was −0.85 bpm (LoA −6.2 to 4.5 bpm) for HR, −1.3 mmHg (LoA −19 to 17 mmHg) for standard versus wireless SBP, 2.9 mmHg (LoA −17 to 22) for standard versus wireless DBP, and 1.7% (LoA −1.4 mmHg to 4.8 mmHg) for SpO 2 , comparing standard versus wireless monitoring. The mean bias of arterial blood gas analysis versus wireless SpO 2 measurements was 0.02% (LoA −0.02% to 0.06%), while the mean bias of direct observation of RR compared to wireless measurements was 0.0 brpm (LoA −2.6 brpm to 2.6 brpm). 80% of all values compared were within predefined clinical limits. Significance. The agreement between wired and wireless HR, RR, and PR recordings in postoperative patients was acceptable, whereas the agreement for SpO 2 recordings (standard versus wireless) was borderline. Standard wired and wireless BP measurements may be used interchangeably in the clinical setting.


  • Clinical impact of vital sign abnormalities in patients admitted with acute exacerbation of chronic obstructive pulmonary disease: an observational study using continuous wireless monitoring

    by Mikkel Elvekjaer, Søren M. Rasmussen, Katja K. Grønbæk, Celeste M. Porsbjerg, Jens-Ulrik Jensen, Camilla Haahr-Raunkjær, Jesper Mølgaard, Marlene Søgaard, Helge B. D. Sørensen, Eske K. Aasvang, et al.

    Early detection of abnormal vital signs is critical for timely management of acute hospitalised patients and continuous monitoring may improve this. We aimed to assess the association between preceding vital sign abnormalities and serious adverse events (SAE) in patients hospitalised with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). Two hundred patients’ vital signs were wirelessly and continuously monitored with peripheral oxygen saturation, heart rate, and respiratory rate during the first 4 days after admission for AECOPD. Non-invasive blood pressure was also measured every 30–60 min. The primary outcome was occurrence of SAE according to international definitions within 30 days and physiological data were analysed for preceding vital sign abnormalities. Data were presented as the mean cumulative duration of vital sign abnormalities per 24 h and analysed using Wilcoxon rank sum test. SAE during ongoing continuous monitoring occurred in 50 patients (25%). Patients suffering SAE during the monitoring period had on average 455 min (SD 413) per 24 h of any preceding vital sign abnormality versus 292 min (SD 246) in patients without SAE, p = 0.08, mean difference 163 min [95% CI 61–265]. Mean duration of bradypnea (respiratory rate < 11 min−1) was 48 min (SD 173) compared with 30 min (SD 84) in patients without SAE, p = 0.01. In conclusion, the duration of physiological abnormalities was substantial in patients with AECOPD. There were no statistically significant differences between patients with and without SAE in the overall duration of preceding physiological abnormalities. Study registration: http://ClinicalTrials.gov (NCT03660501). Date of registration: Sept 6 2018.


  • Open Access

    Continuously monitored vital signs for detection of myocardial injury in high‐risk patients – An observational study

    by Frederik C. Loft, Søren M. Rasmussen, Mikkel Elvekjaer, Camilla Haahr‐Raunkjaer, Helge B. D. Sørensen, Eske K. Aasvang, Christian S. Meyhoff, WARD‐Project Group

    Background: Patients are at risk of myocardial injury after major non‐cardiac surgery and during acute illness. Myocardial injury is associated with mortality, but often asymptomatic and currently detected through intermittent cardiac biomarker screening. This delays diagnosis, where vital signs deviations may serve as a proxy for early signs of myocardial injury. This study aimed to assess the association between continuous monitored vital sign deviations and subsequent myocardial injury following major abdominal cancer surgery and during acute exacerbation of chronic obstructive pulmonary disease.Methods: Patients undergoing major abdominal cancer surgery or admitted with acute exacerbation of chronic obstructive pulmonary disease had daily troponin measurements. Continuous wireless monitoring of several vital signs was performed for up to 96 h after admission or surgery. The primary exposure was cumulative duration of peripheral oxygen saturation (SpO2) below 85% in the 24 h before the primary outcome of myocardial injury, defined as a new onset ischaemic troponin elevation assessed daily. If no myocardial injury occurred, the primary exposure was based on the first 24 h of measurement.Results: A total of 662 patients were continuously monitored and 113 (17%) had a myocardial injury. Cumulative duration of SpO2 < 85% was significantly associated with myocardial injury (mean difference 14.2 min [95% confidence interval −4.7 to 33.1 min]; p = .005). Durations of hypoxaemia (SpO2 < 88% and SpO2 < 80%), tachycardia (HR > 110 bpm and HR > 130 bpm) and tachypnoea (RR > 24 min−1 and RR > 30 min−1) were also significantly associated with myocardial injury (p < .04, for all).Conclusion: Duration of severely low SpO2 detected by continuous wireless monitoring is significantly associated with myocardial injury in high‐risk patients admitted to hospital wards. The effect of early detection and interventions should be assessed next.


  • Open Access

    Continuous monitoring of vital sign abnormalities; association to clinical complications in 500 postoperative patients

    by Camilla Haahr‐Raunkjaer, Jesper Mølgaard, Mikkel Elvekjaer, Søren M. Rasmussen, Michael P. Achiam, Lars N. Jorgensen, Mette I.V. Søgaard, Katja K. Grønbæk, Anne‐Britt Oxbøll, Helge B. D. Sørensen, et al.

    Background: Patients undergoing major surgery are at risk of complications, so‐called serious adverse events (SAE). Continuous monitoring may detect deteriorating patients by recording abnormal vital signs. We aimed to assess the association between abnormal vital signs inspired by Early Warning Score thresholds and subsequent SAEs in patients undergoing major abdominal surgery.Methods: Prospective observational cohort study continuously monitoring heart rate, respiratory rate, peripheral oxygen saturation, and blood pressure for up to 96 h in 500 postoperative patients admitted to the general ward. Exposure variables were vital sign abnormalities, primary outcome was any serious adverse event occurring within 30 postoperative days. The primary analysis investigated the association between exposure variables per 24 h and subsequent serious adverse events.Results: Serious adverse events occurred in 37% of patients, with 38% occurring during monitoring. Among patients with SAE during monitoring, the median duration of vital sign abnormalities was 272 min (IQR 110–447), compared to 259 min (IQR 153–394) in patients with SAE after monitoring and 261 min (IQR 132–468) in the patients without any SAE (p = .62 for all three group comparisons). Episodes of heart rate ≥110 bpm occurred in 16%, 7.1%, and 3.9% of patients in the time before SAE during monitoring, after monitoring, and without SAE, respectively (p < .002). Patients with SAE after monitoring experienced more episodes of hypotension ≤90 mm Hg/24 h (p = .001).Conclusion: Overall duration of vital sign abnormalities at current thresholds were not significantly associated with subsequent serious adverse events, but more patients with tachycardia and hypotension had subsequent serious adverse events.Trial registration: Clinicaltrials.gov, identifier NCT03491137.


  • Agreement between wireless and standard measurements of vital signs in acute exacerbation of chronic obstructive pulmonary disease: a clinical validation study

    by Mikkel Elvekjaer, Christian Jakob Carlsson, Søren Møller Rasmussen, Celeste Michala Porsbjerg, Katja Kjær Grønbæk, Camilla Haahr-Raunkjær, Helge Bjarup Dissing Sorensen, Eske Kvanner Aasvang, Christian Sylvest Meyhoff

    Objective. Wireless sensors for continuous monitoring of vital signs have potential to improve patient care by earlier detection of deterioration in general ward patients. We aimed to assess agreement between wireless and standard (wired) monitoring devices in patients hospitalized with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). Approach. Paired measurements of vital signs were recorded with 15 min intervals for two hours. The primary outcome was agreement between wireless and standard monitor measurements using the Bland and Altman method to calculate bias with 95% limits of agreement (LoA). We considered LoA of less than ±5 beats min −1 (bpm) acceptable for heart rate (HR), whereas agreement of peripheral oxygen saturation (SpO 2 ), respiratory rate (RR), and blood pressure (BP) were acceptable if within ±3%-points, ±3 breaths min −1 (brpm), and ±10 mmHg, respectively. Main results. 180 sample-pairs of vital signs from 20 with AECOPD patients were recorded for comparison. The wireless versus standard monitor bias was 0.03 (LoA −3.2 to 3.3) bpm for HR measurements, 1.4% (LoA −0.7% to 3.6%) for SpO 2 , −7.8 (LoA −22.3 to 6.8) mmHg for systolic BP and −6.2 (LoA −16.8 to 4.5) mmHg for diastolic BP. The wireless versus standard monitor bias for RR measurements was 0.75 (LoA −6.1 to 7.6) brpm. Significance. Commercially available wireless monitors could accurately measure HR in patients admitted with AECOPD compared to standard wired monitoring. Agreement for SpO 2 were borderline acceptable while agreement for RR and BP should be interpreted with caution.


  • Continuous peripheral perfusion index in patients admitted to hospital wards – An observational study

    by Patrick S. Rasmussen, Eske K. Aasvang, Rasmus M. Olsen, Camilla Haahr‐Raunkjaer, Mikkel Elvekjaer, Helge B. D. Sørensen, Christian S. Meyhoff

    Introduction: Risk patients admitted to hospital wards may quickly develop haemodynamic deterioration and early recognition has high priority to allow preventive intervention. The peripheral perfusion index (PPI) may be an indicator of circulatory distress by assessing peripheral perfusion non‐invasively from photoplethysmography. We aimed to describe the characteristics of PPI in hospitalized patients since this is not well‐studied.Materials and Methods: Patients admitted due to either acute exacerbation of chronic obstructive pulmonary disease (AECOPD) or after major abdominal cancer surgery were included in this study. Patients were monitored continuously up to 96 hours with a pulse oximeter. Comparisons between median PPI each day, time of day and admission type were described with mean difference (MD) and were analysed using Wilcoxon rank sum test and related to morbidity and mortality.Results: PPI data from 291 patients were recorded for a total of 9279 hours. Median PPI fell from 1.4 (inter quartile range, IQR 0.9‐2.3) on day 1 to 1.0 (IQR 0.6‐1.6) on day 4. Significant differences occurred between PPI day vs evening (MD = 0.18, 95% CI 0.16‐0.20, P = .028), day vs night (MD = 0.56, 95% CI 0.49‐0.62, P < .0001) and evening vs night (MD = 0.38, 95% CI 0.33‐0.42, P = .002). No significant difference in median PPI between AECOPD and surgical patients was found (MD = 0.15, 95% CI −0.08‐0.38, P = .62).Conclusion: Lower PPI during daytime vs evening and night‐time were seen for both populations. The highest frequency of serious adverse events and mortality was seen among patients with low median PPI. The clinical impact of PPI monitoring needs further confirmation.


  • Physiological abnormalities in patients admitted with acute exacerbation of COPD: an observational study with continuous monitoring

    by for the WARD-Project Group, Mikkel Elvekjaer, Eske K. Aasvang, Rasmus M. Olsen, Helge B. D. Sørensen, Celeste M. Porsbjerg, Jens-Ulrik Jensen, Camilla Haahr-Raunkjær, Christian S. Meyhoff

    Acute exacerbations of chronic obstructive pulmonary disease (AECOPD) may rapidly require intensive care treatment. Evaluation of vital signs is necessary to detect physiological abnormalities (micro events), but patients may deteriorate between measurements. We aimed to assess if continuous monitoring of vital signs in patients admitted with AECOPD detects micro events more often than routine ward rounds. In this observational pilot study (NCT03467815), 30 adult patients admitted with AECOPD were included. Patients were continuously monitored with peripheral oxygen saturation (SpO2), heart rate, and respiratory rate during the first 4 days after admission. Hypoxaemic events were defined as decreased SpO2 for at least 60 s. Non-invasive blood pressure was also measured every 15–60 min. Clinical ward staff measured vital signs as part of Early Warning Score (EWS). Data were analysed using Fisher’s exact test or Wilcoxon rank sum test. Continuous monitoring detected episodes of SpO2 < 92% in 97% versus 43% detected by conventional EWS (p < 0.0001). Events of SpO2 < 88% was detected in 90% with continuous monitoring compared with 13% with EWS (p < 0.0001). Sixty-three percent of patients had episodes of SpO2 < 80% recorded by continuous monitoring and 17% had events lasting longer than 10 min. No events of SpO2 < 80% was detected by EWS. Micro events of tachycardia, tachypnoea, and bradypnoea were also more frequently detected by continuous monitoring (p < 0.02 for all). Moderate and severe episodes of desaturation and other cardiopulmonary micro events during hospitalization for AECOPD are common and most often not detected by EWS.