Oishee Mazumder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oishee Mazumder has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Aniruddha Sinha
TCS Research, Tata Consultancy Services, Kolkata, India
2 shared publicationsAvik Ghose
TCS Research, Tata Consultancy Services Ltd., Kolkata, West Bengal, India
2 shared publicationsRohan Banerjee
TCS Research, Tata Consultancy Services Ltd., Kolkata, West Bengal, India
2 shared publicationsAnanda Sankar Kundu
IIEST,School of Mechatronics and Robotics,Shibpur Howrah,India
1 shared publication- Aniruddha Sinha
Tata Consultancy Services Ltd
1 shared publication Ayan Mukherjee
TCS Research, Tata Consultancy Services, Kolkata, India
1 shared publication
Latest Publications
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (5) , 2136-2146
Synthetic PPG Signal Generation to Improve Coronary Artery Disease Classification: Study With Physical Model of Cardiovascular System
This paper presents a novel approach of generating synthetic Photoplethysmogram (PPG) data using a physical model of the cardiovascular system to improve classifier performance with a combination of synthetic and real data. The physical model is an in-silico cardiac computational model, consisting of a four-chambered heart with electrophysiology, hemodynamic, and blood pressure auto-regulation functionality. Starting with a small number of measured PPG data, the cardiac model is used to synthesize healthy as well as PPG time-series pertaining to coronary artery disease (CAD) by varying pathophysiological parameters. A Variational Autoencoder (VAE) structure is proposed to derive a statistical feature space for CAD classification. Results are presented in two perspectives namely, (i) using artificially reduced real disease data and (ii) using all the real disease data. In both cases, by augmenting with the synthetic data for training, the performance (sensitivity, specificity) of the classifier changes from (i) (0.65, 1) to (1, 0.9) and (ii) (1, 0.95) to (1, 1). The proposed hybrid approach of combining physical modelling and statistical feature space selection generates realistic PPG data with pathophysiological interpretation and can outperform a baseline Generative Adversarial Network (GAN) architecture with a relatively small amount of real data for training. This proposed method could aid as a substitution technique for handling the problem of bulk data required for training machine learning algorithms for cardiac health-care applications.
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (5) , 2136-2146
Synthetic PPG Signal Generation to Improve Coronary Artery Disease Classification: Study With Physical Model of Cardiovascular System
This paper presents a novel approach of generating synthetic Photoplethysmogram (PPG) data using a physical model of the cardiovascular system to improve classifier performance with a combination of synthetic and real data. The physical model is an in-silico cardiac computational model, consisting of a four-chambered heart with electrophysiology, hemodynamic, and blood pressure auto-regulation functionality. Starting with a small number of measured PPG data, the cardiac model is used to synthesize healthy as well as PPG time-series pertaining to coronary artery disease (CAD) by varying pathophysiological parameters. A Variational Autoencoder (VAE) structure is proposed to derive a statistical feature space for CAD classification. Results are presented in two perspectives namely, (i) using artificially reduced real disease data and (ii) using all the real disease data. In both cases, by augmenting with the synthetic data for training, the performance (sensitivity, specificity) of the classifier changes from (i) (0.65, 1) to (1, 0.9) and (ii) (1, 0.95) to (1, 1). The proposed hybrid approach of combining physical modelling and statistical feature space selection generates realistic PPG data with pathophysiological interpretation and can outperform a baseline Generative Adversarial Network (GAN) architecture with a relatively small amount of real data for training. This proposed method could aid as a substitution technique for handling the problem of bulk data required for training machine learning algorithms for cardiac health-care applications.
- Open Access
- 10 December 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12, 787180
Computational Model for Therapy Optimization of Wearable Cardioverter Defibrillator: Shockable Rhythm Detection and Optimal Electrotherapy
Wearable cardioverter defibrillator (WCD) is a life saving, wearable, noninvasive therapeutic device that prevents fatal ventricular arrhythmic propagation that leads to sudden cardiac death (SCD). WCD are frequently prescribed to patients deemed to be at high arrhythmic risk but the underlying pathology is potentially reversible or to those who are awaiting an implantable cardioverter-defibrillator. WCD is programmed to detect appropriate arrhythmic events and generate high energy shock capable of depolarizing the myocardium and thus re-initiating the sinus rhythm. WCD guidelines dictate very high reliability and accuracy to deliver timely and optimal therapy. Computational model-based process validation can verify device performance and benchmark the device setting to suit personalized requirements. In this article, we present a computational pipeline for WCD validation, both in terms of shock classification and shock optimization. For classification, we propose a convolutional neural network-“Long Short Term Memory network (LSTM) full form” (Convolutional neural network- Long short term memory network (CNN-LSTM)) based deep neural architecture for classifying shockable rhythms like Ventricular Fibrillation (VF), Ventricular Tachycardia (VT) vs. other kinds of non-shockable rhythms. The proposed architecture has been evaluated on two open access ECG databases and the classification accuracy achieved is in adherence to American Heart Association standards for WCD. The computational model developed to study optimal electrotherapy response is an in-silico cardiac model integrating cardiac hemodynamics functionality and a 3D volume conductor model encompassing biophysical simulation to compute the effect of shock voltage on myocardial potential distribution. Defibrillation efficacy is simulated for different shocking electrode configurations to assess the best defibrillator outcome with minimal myocardial damage. While the biophysical simulation provides the field distribution through Finite Element Modeling during defibrillation, the hemodynamic module captures the changes in left ventricle functionality during an arrhythmic event. The developed computational model, apart from acting as a device validation test-bed, can also be used for the design and development of personalized WCD vests depending on subject-specific anatomy and pathology.
- 10 December 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12, 787180
Open AccessComputational Model for Therapy Optimization of Wearable Cardioverter Defibrillator: Shockable Rhythm Detection and Optimal Electrotherapy
Wearable cardioverter defibrillator (WCD) is a life saving, wearable, noninvasive therapeutic device that prevents fatal ventricular arrhythmic propagation that leads to sudden cardiac death (SCD). WCD are frequently prescribed to patients deemed to be at high arrhythmic risk but the underlying pathology is potentially reversible or to those who are awaiting an implantable cardioverter-defibrillator. WCD is programmed to detect appropriate arrhythmic events and generate high energy shock capable of depolarizing the myocardium and thus re-initiating the sinus rhythm. WCD guidelines dictate very high reliability and accuracy to deliver timely and optimal therapy. Computational model-based process validation can verify device performance and benchmark the device setting to suit personalized requirements. In this article, we present a computational pipeline for WCD validation, both in terms of shock classification and shock optimization. For classification, we propose a convolutional neural network-“Long Short Term Memory network (LSTM) full form” (Convolutional neural network- Long short term memory network (CNN-LSTM)) based deep neural architecture for classifying shockable rhythms like Ventricular Fibrillation (VF), Ventricular Tachycardia (VT) vs. other kinds of non-shockable rhythms. The proposed architecture has been evaluated on two open access ECG databases and the classification accuracy achieved is in adherence to American Heart Association standards for WCD. The computational model developed to study optimal electrotherapy response is an in-silico cardiac model integrating cardiac hemodynamics functionality and a 3D volume conductor model encompassing biophysical simulation to compute the effect of shock voltage on myocardial potential distribution. Defibrillation efficacy is simulated for different shocking electrode configurations to assess the best defibrillator outcome with minimal myocardial damage. While the biophysical simulation provides the field distribution through Finite Element Modeling during defibrillation, the hemodynamic module captures the changes in left ventricle functionality during an arrhythmic event. The developed computational model, apart from acting as a device validation test-bed, can also be used for the design and development of personalized WCD vests depending on subject-specific anatomy and pathology.
- 10 November 2019
- Published by Springer Nature in Communications in Computer and Information Science
- p. 111-120
Effect of Age on Postural Balance and Control: Graph Based Connectivity Analysis on Brain Network
- 10 November 2019
- Published by Springer Nature in Communications in Computer and Information Science
- p. 111-120
Effect of Age on Postural Balance and Control: Graph Based Connectivity Analysis on Brain Network
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 114-119
Human—Hand Posture Classification For Robotic Teleoperation Using Wearable Sensor
The aim of this work is to control a teleoperated robotic gripper to grasp objects of different shapes using an efficient posture classification algorithm. Two Inertial Measurement Unit sensors are attached to a wearable glove and using it the human operator performs 5 different postures related to grasping. The feature selected for experimentation is Unit Quaternion. Classification is done with 2 different classifier algorithms, Neural Networks and Random Forests. This is followed by a basic mapping to a 10 degrees of freedom robotic hand. A comparative study of the classifier algorithms is carried out to select the most efficient algorithm for sensor based posture recognition.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 114-119
Human—Hand Posture Classification For Robotic Teleoperation Using Wearable Sensor
The aim of this work is to control a teleoperated robotic gripper to grasp objects of different shapes using an efficient posture classification algorithm. Two Inertial Measurement Unit sensors are attached to a wearable glove and using it the human operator performs 5 different postures related to grasping. The feature selected for experimentation is Unit Quaternion. Classification is done with 2 different classifier algorithms, Neural Networks and Random Forests. This is followed by a basic mapping to a 10 degrees of freedom robotic hand. A comparative study of the classifier algorithms is carried out to select the most efficient algorithm for sensor based posture recognition.