CSCourtney E. Shell

Courtney E. Shell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Courtney E. Shell has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Migration of a Cervical Artificial Disc Core: A Case Report of a Devastating Late-Occurring Complication

    by Courtney E.S. Zumalt, Alexa B. Bodman, Craig A. Kuhns

    Study Design: Case report. Objective: Report a devastating cervical disc replacement complication underappreciated in the literature. Summary of Background Data: As many as 3000 patients receive single-level cervical disc replacements every year in the United States. Commonly acknowledged long-term complications may burden the patient ( e.g. , revision surgeries), but the potential for severe permanent neurological harm is not widely recognized. Differences in implant design impact this potential harm. Materials and Methods: We present a case report of a 28-year-old man, who had undergone cervical artificial disc replacement five years previously, thatpresented to our emergency department with sudden onset of quadriplegia after four days of worsening neck pain. Imaging revealed the artificial disc core displaced posteriorly into the spinal canal, confirmed during emergent surgical removal followed by anterior cervical fusion. Results: Despite successful removal of the migrated implant within 24 hours of his presentation with quadriplegia and revision with solid fusion, 14 months postrevision, the patient remains wheelchair-bound with complete C6-level quadriplegia. Physical therapy has improved his hand function, core strength, and range of motion. Conclusion: Core migration may cause catastrophic complications and occur years after implantation without a traumatic cause. This risk appears more likely with postoperative kyphotic device alignment and certain disc replacement implants. We found literature reporting similar incidents for two additional patients, although they had less drastic deficits. Our case report seeks to bring awareness to surgeons and patients of this long-term complication and shows the need for investigation into potential causes and prevention. Level of Evidence: Level V.

  • Open Access

    Author Correction: Ambulatory searching task reveals importance of somatosensation for lower-limb amputees

    by Breanne P. Christie, Hamid Charkhkar, Courtney E. Shell, Christopher J. Burant, Dustin J. Tyler, Ronald J. Triolo

  • Open Access

    Ambulatory searching task reveals importance of somatosensation for lower-limb amputees

    by Breanne P. Christie, Hamid Charkhkar, Courtney E. Shell, Christopher J. Burant, Dustin J. Tyler, Ronald J. Triolo

    The contribution of somatosensation to locomotor deficits in below-knee amputees (BKAs) has not been fully explored. Unilateral disruption of plantar sensation causes able-bodied individuals to adopt locomotor characteristics that resemble those of unilateral BKAs, suggesting that restoring somatosensation may improve locomotion for amputees. In prior studies, we demonstrated that electrically stimulating the residual nerves of amputees elicited somatosensory percepts that were felt as occurring in the missing foot. Subsequently, we developed a sensory neuroprosthesis that modulated stimulation-evoked sensation in response to interactions between the prosthesis and the environment. To characterize the impact of the sensory neuroprosthesis on locomotion, we created a novel ambulatory searching task. The task involved walking on a horizontal ladder while blindfolded, which engaged plantar sensation while minimizing visual compensation. We first compared the performance of six BKAs to 14 able-bodied controls. Able-bodied individuals demonstrated higher foot placement accuracy than BKAs, indicating that the ladder test was sensitive enough to detect locomotor deficits. When three of the original six BKAs used the sensory neuroprosthesis, the tradeoff between speed and accuracy significantly improved for two of them. This study advanced our understanding of how cutaneous plantar sensation can be used to acquire action-related information during challenging locomotor tasks.


  • Neural engineering: the process, applications, and its role in the future of medicine

    by Evon S Ereifej, Courtney E Shell, Jonathon S Schofield, Hamid Charkhkar, Ivana Cuberovic, Alan D Dorval, Emily L Graczyk, Takashi D Y Kozai, Kevin J Otto, Dustin J Tyler, et al.

    Objective . Recent advances in neural engineering have restored mobility to people with paralysis, relieved symptoms of movement disorders, reduced chronic pain, restored the sense of hearing, and provided sensory perception to individuals with sensory deficits. Approach . This progress was enabled by the team-based, interdisciplinary approaches used by neural engineers. Neural engineers have advanced clinical frontiers by leveraging tools and discoveries in quantitative and biological sciences and through collaborations between engineering, science, and medicine. The movement toward bioelectronic medicines, where neuromodulation aims to supplement or replace pharmaceuticals to treat chronic medical conditions such as high blood pressure, diabetes and psychiatric disorders is a prime example of a new frontier made possible by neural engineering. Although one of the major goals in neural engineering is to develop technology for clinical applications, this technology may also offer unique opportunities to gain insight into how biological systems operate. Main results . Despite significant technological progress, a number of ethical and strategic questions remain unexplored. Addressing these questions will accelerate technology development to address unmet needs. The future of these devices extends far beyond treatment of neurological impairments, including potential human augmentation applications. Our task, as neural engineers, is to push technology forward at the intersection of disciplines, while responsibly considering the readiness to transition this technology outside of the laboratory to consumer products. Significance . This article aims to highlight the current state of the neural engineering field, its links with other engineering and science disciplines, and the challenges and opportunities ahead. The goal of this article is to foster new ideas for innovative applications in neurotechnology.


  • Open Access

    Visual inputs and postural manipulations affect the location of somatosensory percepts elicited by electrical stimulation

    by Breanne P. Christie, Hamid Charkhkar, Courtney E. Shell, Paul D. Marasco, Dustin J. Tyler, Ronald J. Triolo

    The perception of somatosensation requires the integration of multimodal information, yet the effects of vision and posture on somatosensory percepts elicited by neural stimulation are not well established. In this study, we applied electrical stimulation directly to the residual nerves of trans-tibial amputees to elicit sensations referred to their missing feet. We evaluated the influence of congruent and incongruent visual inputs and postural manipulations on the perceived size and location of stimulation-evoked somatosensory percepts. We found that although standing upright may cause percept size to change, congruent visual inputs and/or body posture resulted in better localization. We also observed visual capture: the location of a somatosensory percept shifted toward a visual input when vision was incongruent with stimulation-induced sensation. Visual capture did not occur when an adopted posture was incongruent with somatosensation. Our results suggest that internal model predictions based on postural manipulations reinforce perceived sensations, but do not alter them. These characterizations of multisensory integration are important for the development of somatosensory-enabled prostheses because current neural stimulation paradigms cannot replicate the afferent signals of natural tactile stimuli. Nevertheless, multisensory inputs can improve perceptual precision and highlight regions of the foot important for balance and locomotion.


  • Open Access

    High-density peripheral nerve cuffs restore natural sensation to individuals with lower-limb amputations

    by Hamid Charkhkar, Courtney E Shell, Paul D Marasco, Gilles J Pinault, Dustin J Tyler, Ronald J Triolo

    Objective. Sensory input in lower-limb amputees is critically important to maintaining balance, preventing falls, negotiating uneven terrain, responding to unexpected perturbations, and developing the confidence required for societal participation and public interactions in unfamiliar environments. Despite noteworthy advances in robotic prostheses for lower-limb amputees, such as microprocessor knees and powered ankles, natural somatosensory feedback from the lost limb has not yet been incorporated in current prosthetic technologies. Approach. In this work, we report eliciting somatic sensation with neural stimulation delivered by chronically-implanted, non-penetrating nerve cuff electrodes in two transtibial amputees. High-density, flexible, 16-contact nerve cuff electrodes were surgically implanted for the selective activation of sensory fascicles in the nerves of the posterior thigh above the knee. Electrical pulses at safe levels were delivered to the nerves by an external stimulator via percutaneous leads attached to the cuff electrodes. Main results. The neural stimulation was perceived by participants as sensation originating from the missing limb. We quantitatively and qualitatively ascertained the intensity, modality as well as the location and stability of the perceived sensations. Stimulation through individual contacts within the nerve cuffs evoked repeatable sensations of various modalities and at discrete locations projected to the missing toes, foot and ankle, as well as in the residual limb. In addition, we observed a high overlap in reported locations between distal versus proximal cuffs suggesting that the same sensory responses could be elicited from more proximal points on the nerve. Significance. Based on these findings, the high-density cuff technology is suitable for restoring natural sensation to lower-limb amputees and could be utilized in developing a neuroprosthesis with natural sensory feedback. The overlap in reported locations between proximal and distal cuffs indicates that our approach might be applicable to transfemoral amputees where distal muscles and branches of sciatic nerve are not available.


  • Top Cited Papers

    Illusory movement perception improves motor control for prosthetic hands

    by Paul D. Marasco, Jacqueline S. Hebert, Jon W. Sensinger, Courtney E. Shell, Jonathon S. Schofield, Zachary C. Thumser, Raviraj Nataraj, Dylan T. Beckler, Michael R. Dawson, Dan H. Blustein, et al.

    A perceptual illusion provides the sensation of complex bionic hand movements to human amputees, allowing real-time movement control without the necessity of vision.


  • Open Access

    Identifying classifier input signals to predict a cross-slope during transtibial amputee walking

    by Courtney E Shell, Glenn K Klute, Richard R Neptune

    Advanced prosthetic foot designs often incorporate mechanisms that adapt to terrain changes in real-time to improve mobility. Early identification of terrain (e.g., cross-slopes) is critical to appropriate adaptation. This study suggests that a simple classifier based on linear discriminant analysis can accurately predict a cross-slope encountered (0°, -15°, 15°) using measurements from the residual limb, primarily from the prosthesis itself. The classifier was trained and tested offline using motion capture and in-pylon sensor data collected during walking trials in mid-swing and early stance. Residual limb kinematics, especially measurements from the foot, shank and ankle, successfully predicted the cross-slope terrain with high accuracy (99%). Although accuracy decreased when predictions were made for test data instead of the training data, the accuracy was still relatively high for one input signal set (>89%) and moderate for three others (>71%). This suggests that classifiers can be designed and generalized to be effective for new conditions and/or subjects. While measurements of shank acceleration and angular velocity from only in-pylon sensors were insufficient to accurately predict the cross-slope terrain, the addition of foot and ankle kinematics from motion capture data allowed accurate terrain prediction. Inversion angular velocity and foot vertical velocity were particularly useful. As in-pylon sensor data and shank kinematics from motion capture appeared interchangeable, combining foot and ankle kinematics from prosthesis-mounted sensors with shank kinematics from in-pylon sensors may provide enough information to accurately predict the terrain.


  • Open Access

    The neural response properties and cortical organization of a rapidly adapting muscle sensory group response that overlaps with the frequencies that elicit the kinesthetic illusion

    by Paul D. Marasco, Dennis J. Bourbeau, Courtney E. Shell, Rafael Granja-Vazquez, Jason G. Ina

    Kinesthesia is the sense of limb movement. It is fundamental to efficient motor control, yet its neurophysiological components remain poorly understood. The contributions of primary muscle spindles and cutaneous afferents to the kinesthetic sense have been well studied; however, potential contributions from muscle sensory group responses that are different than the muscle spindles have not been ruled out. Electrophysiological recordings in peripheral nerves and brains of male Sprague Dawley rats with a degloved forelimb preparation provide evidence of a rapidly adapting muscle sensory group response that overlaps with vibratory inputs known to generate illusionary perceptions of limb movement in humans (kinesthetic illusion). This group was characteristically distinct from type Ia muscle spindle fibers, the receptor historically attributed to limb movement sensation, suggesting that type Ia muscle spindle fibers may not be the sole carrier of kinesthetic information. The sensory-neural structure of muscles is complex and there are a number of possible sources for this response group; with Golgi tendon organs being the most likely candidate. The rapidly adapting muscle sensory group response projected to proprioceptive brain regions, the rodent homolog of cortical area 3a and the second somatosensory area (S2), with similar adaption and frequency response profiles between the brain and peripheral nerves. Their representational organization was muscle-specific (myocentric) and magnified for proximal and multi-articulate limb joints. Projection to proprioceptive brain areas, myocentric representational magnification of muscles prone to movement error, overlap with illusionary vibrational input, and resonant frequencies of volitional motor unit contraction suggest that this group response may be involved with limb movement processing.