Nilgun Tekkesin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nilgun Tekkesin has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Cumhur Kilinç
2 shared publicationsCumhur Kılınc
Department of Biochemistry Dicle University Diyarbakır Turkey
2 shared publicationsKenan Keskin
Department of Microbiology and Disease, Clinical Laboratory, Memorial Hospital, Istanbul, Turkey
2 shared publicationsCumhur Kilinc
1 shared publicationCumhur Kılınç
1 shared publicationDuygu İbRişim
Department of Gastroenterology, Memorial Hospital, Ataşehir, Istanbul, Turkey
1 shared publication
Latest Publications
- Open Access
- 12 November 2015
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 15 (11) , 932-937
Thromboelastography for the monitoring of the antithrombotic effect of low-molecular-weight heparin after major orthopedic surgery
Anadolu Kardiyoloji Dergisi, Anadolu Kardiyol Derg, The Anatolian Journal of Cardiology, Anatol J Cardiol, Cardiology, Cardiovascular Medicine, Surgery, Pediatric Cardiology, Angiology
- 12 November 2015
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 15 (11) , 932-937
Open AccessThromboelastography for the monitoring of the antithrombotic effect of low-molecular-weight heparin after major orthopedic surgery
Anadolu Kardiyoloji Dergisi, Anadolu Kardiyol Derg, The Anatolian Journal of Cardiology, Anatol J Cardiol, Cardiology, Cardiovascular Medicine, Surgery, Pediatric Cardiology, Angiology
- Open Access
- 1 January 2014
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Medical Sciences
- Vol. 34 (4) , 363-372
The Frequency of Aspirin Resistance and Its Relationship with Clinical and Laboratory Parameters in Patients with Stable Coronary Artery Disease
- 1 January 2014
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Medical Sciences
- Vol. 34 (4) , 363-372
Open AccessThe Frequency of Aspirin Resistance and Its Relationship with Clinical and Laboratory Parameters in Patients with Stable Coronary Artery Disease
- Open Access
- 1 September 2012
- Published by Akademiai Kiado Zrt. in Interventional Medicine and Applied Science
- Vol. 4 (3) , 132-138
Urinary neutrophil gelatinase-associated lipocalin (uNGAL) levels in patients with nonalcoholic fatty liver disease
Background/Aims: Nonalcoholic fatty liver disease (NAFLD), one of the most common forms of chronic liver disease, is closely associated with obesity and insulin resistance (IR). Adipokines secreted by adipose tissue have recently been implicated in initiating and perpetuating the chronic inflammatory state observed in obesity and NAFLD. Recent studies suggest neutrophil gelatinase-associated lipocalin (NGAL) plays a key role in the pathogenesis of IR. The aims of this study were to determine urinary NGAL levels in patients with ultrasonography proven NAFLD and to correlate these levels with the metabolic profile and fibrosis grade in this population.Methodology: Our cohort consisted of 65 consecutive patients undergoing abdominal ultrasonography for clinical suspicion of NAFLD. Patients were subsequently divided into two groups: no steatosis (n=20) and steatosis (n=45). The stage of fibrosis was measured using a four-point scale. Urinary NGAL was measured by a specific microparticle enzyme immunoassay. The degree of insulin resistance was determined by the homeostatic model assessment (HOMA). Glucose, insulin, lipid profile, and transaminases were also measured.Results: Urinary NGAL levels correlated with body mass index, HOMA, fasting glucose, and insulin levels in patients with steatosis. Moreover, uNGAL levels were higher in patients with steatosis compared to those with no steatosis (49.8 ng/mL and 22.7 ng/mL, respectively) with a statistically significant difference (pp<0.001).Conclusions: Our study demonstrates that in adult patients with NAFLD, uNGAL levels correlate with BMI, insulin resistance, and lipid profiles, and identifies a novel association between uNGAL levels and hepatocellular injury in these patients.
- 1 September 2012
- Published by Akademiai Kiado Zrt. in Interventional Medicine and Applied Science
- Vol. 4 (3) , 132-138
Open AccessUrinary neutrophil gelatinase-associated lipocalin (uNGAL) levels in patients with nonalcoholic fatty liver disease
Background/Aims: Nonalcoholic fatty liver disease (NAFLD), one of the most common forms of chronic liver disease, is closely associated with obesity and insulin resistance (IR). Adipokines secreted by adipose tissue have recently been implicated in initiating and perpetuating the chronic inflammatory state observed in obesity and NAFLD. Recent studies suggest neutrophil gelatinase-associated lipocalin (NGAL) plays a key role in the pathogenesis of IR. The aims of this study were to determine urinary NGAL levels in patients with ultrasonography proven NAFLD and to correlate these levels with the metabolic profile and fibrosis grade in this population.Methodology: Our cohort consisted of 65 consecutive patients undergoing abdominal ultrasonography for clinical suspicion of NAFLD. Patients were subsequently divided into two groups: no steatosis (n=20) and steatosis (n=45). The stage of fibrosis was measured using a four-point scale. Urinary NGAL was measured by a specific microparticle enzyme immunoassay. The degree of insulin resistance was determined by the homeostatic model assessment (HOMA). Glucose, insulin, lipid profile, and transaminases were also measured.Results: Urinary NGAL levels correlated with body mass index, HOMA, fasting glucose, and insulin levels in patients with steatosis. Moreover, uNGAL levels were higher in patients with steatosis compared to those with no steatosis (49.8 ng/mL and 22.7 ng/mL, respectively) with a statistically significant difference (pp<0.001).Conclusions: Our study demonstrates that in adult patients with NAFLD, uNGAL levels correlate with BMI, insulin resistance, and lipid profiles, and identifies a novel association between uNGAL levels and hepatocellular injury in these patients.
- 1 June 2012
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 23 (4) , 299-303
Discard first tube for coagulation testing
Tissue thromboplastin may contaminate the first tube sample due to the trauma of the venipuncture, and therefore, affect the accuracy of coagulation testing. This practice was stopped by Clinical and Laboratory Standards Institute after several studies. However, most of the studies have verified these conclusions and refuted the need for a discard tube when drawing samples for coagulation tests in healthy groups. The purpose of our study was to evaluate the clinical importance of discarding a tube for prothrombin time (PT) determinations on large samples with international normalized ratio (INR) values between and over targeted therapeutic range. Patients receiving oral anticoagulation therapy (OAT) managed by our cardiology service were selected for this study. Tube 1 was always treated as the discard tube. Tube 2 was allocated to be analyzed along with the tube 1 for coagulation tests. Individual values were grouped into four cohorts according to the INR range. The ranges were as follows: less than 2.0, 2.1-3.0, 3.1-4.5 and more. Three hundred and seventy-six samples were drawn for PT/INR and activated partial thromboplastin time testing. We found statistically significant differences between tube 1 and tube 2 (P < 0.05), and satisfactory correlation coefficients were obtained by linear regression analysis (0.86 or greater in all cases). This study consisted of a high number of samples. Our data suggest that drawing a discard tube is still necessary for coagulation testing. Consideration should be given to revising the international guidelines related to the necessity of a discard tube for repeated evaluation of coagulation tests especially receiving long-term OAT.
- 1 June 2012
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 23 (4) , 299-303
Discard first tube for coagulation testing
Tissue thromboplastin may contaminate the first tube sample due to the trauma of the venipuncture, and therefore, affect the accuracy of coagulation testing. This practice was stopped by Clinical and Laboratory Standards Institute after several studies. However, most of the studies have verified these conclusions and refuted the need for a discard tube when drawing samples for coagulation tests in healthy groups. The purpose of our study was to evaluate the clinical importance of discarding a tube for prothrombin time (PT) determinations on large samples with international normalized ratio (INR) values between and over targeted therapeutic range. Patients receiving oral anticoagulation therapy (OAT) managed by our cardiology service were selected for this study. Tube 1 was always treated as the discard tube. Tube 2 was allocated to be analyzed along with the tube 1 for coagulation tests. Individual values were grouped into four cohorts according to the INR range. The ranges were as follows: less than 2.0, 2.1-3.0, 3.1-4.5 and more. Three hundred and seventy-six samples were drawn for PT/INR and activated partial thromboplastin time testing. We found statistically significant differences between tube 1 and tube 2 (P < 0.05), and satisfactory correlation coefficients were obtained by linear regression analysis (0.86 or greater in all cases). This study consisted of a high number of samples. Our data suggest that drawing a discard tube is still necessary for coagulation testing. Consideration should be given to revising the international guidelines related to the necessity of a discard tube for repeated evaluation of coagulation tests especially receiving long-term OAT.
- 24 May 2012
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 26 (3) , 125-129
Optical and Mechanical Clot Detection Methodologies: A Comparison Study for Routine Coagulation Testing
Automated coagulation analyzers are preferred to meet increasing coagulation test volume. Two distinct technological families exist based on optical and mechanical clot detection methodologies. Which one is superior to the other is still a conflict and needs new studies. We have compared prothrombin and activated partial thromboplastin results obtained with mechanical method with those obtained by photo‐optical method used routinely in our specialized laboratory. The instrumental results showed good precision ranging between 0.7% and 1.8% coefficient of variation. Statistical analysis demonstrated an excellent correlation between the photo‐optical and mechanical analyzers for PT (R2 0.97), and aPTT (R2 0.85). Correlation between the two clot‐detection systems was maintained even when measuring turbid samples (R2 ≥ 0.97 for two tests). J. Clin. Lab. Anal. 26:125‐129, 2012.
- 24 May 2012
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 26 (3) , 125-129
Optical and Mechanical Clot Detection Methodologies: A Comparison Study for Routine Coagulation Testing
Automated coagulation analyzers are preferred to meet increasing coagulation test volume. Two distinct technological families exist based on optical and mechanical clot detection methodologies. Which one is superior to the other is still a conflict and needs new studies. We have compared prothrombin and activated partial thromboplastin results obtained with mechanical method with those obtained by photo‐optical method used routinely in our specialized laboratory. The instrumental results showed good precision ranging between 0.7% and 1.8% coefficient of variation. Statistical analysis demonstrated an excellent correlation between the photo‐optical and mechanical analyzers for PT (R2 0.97), and aPTT (R2 0.85). Correlation between the two clot‐detection systems was maintained even when measuring turbid samples (R2 ≥ 0.97 for two tests). J. Clin. Lab. Anal. 26:125‐129, 2012.
- Open Access
- 1 January 2012
- Published by Herbert Publications PVT LTD in HOAJ Biology
- Vol. 1 (1)
Diagnosis of toxoplasmosis in pregnancy: a review
- 1 January 2012
- Published by Herbert Publications PVT LTD in HOAJ Biology
- Vol. 1 (1)
Open AccessDiagnosis of toxoplasmosis in pregnancy: a review
- Open Access
- 11 March 2011
- Published by Modestum Ltd in Journal of Clinical and Experimental Investigations
- Vol. 2 (1) , 42-49
Investigation of Framingham Risk Factors in Turkish adults
Objectives: The aim of this study was to determine 10-year risk for development of cardiovascular diseases using Framingham risk scoring as a tool for the estimation of coronary risk and renew the blood lipid levels. Materials and methods: Samples from fasting 3169 healthy donors declaring as having no cardiovascular disease and diabetes (1800 women, mean age 46.8±9.2 years) and 1369 men, mean age 46.03±8.4 years) were tested and scored according to risk factors in both genders. Results: When average values were considered, total cholesterol level was higher (204±42 mg/dL) according to reactive insert reference values. High total kolesterol and low HDL-C levels were seen in 20% and 19.5% of men and 32.6% and 1.1% of women, respectively. The number of participants having systolic blood pressure ≥130 mmHg and diastolic blood pressure ≥ 85 mmHg were 775 (24.5%) and the distribution of those values was 10.6 % in men and 13.9% in women. The mean 10-year cardiovascular disease risks were 9.4 % in men and 4.6% in women among 3169 participants. Conclusion: A 10-year risk of coronary disease, in Turkish males was 2-fold higher than in Turkish females. Use of Framingham study in clinical assessments maintains to be a valid method in preventive approaches for development of cardiovascular diseases.
- 11 March 2011
- Published by Modestum Ltd in Journal of Clinical and Experimental Investigations
- Vol. 2 (1) , 42-49
Open AccessInvestigation of Framingham Risk Factors in Turkish adults
Objectives: The aim of this study was to determine 10-year risk for development of cardiovascular diseases using Framingham risk scoring as a tool for the estimation of coronary risk and renew the blood lipid levels. Materials and methods: Samples from fasting 3169 healthy donors declaring as having no cardiovascular disease and diabetes (1800 women, mean age 46.8±9.2 years) and 1369 men, mean age 46.03±8.4 years) were tested and scored according to risk factors in both genders. Results: When average values were considered, total cholesterol level was higher (204±42 mg/dL) according to reactive insert reference values. High total kolesterol and low HDL-C levels were seen in 20% and 19.5% of men and 32.6% and 1.1% of women, respectively. The number of participants having systolic blood pressure ≥130 mmHg and diastolic blood pressure ≥ 85 mmHg were 775 (24.5%) and the distribution of those values was 10.6 % in men and 13.9% in women. The mean 10-year cardiovascular disease risks were 9.4 % in men and 4.6% in women among 3169 participants. Conclusion: A 10-year risk of coronary disease, in Turkish males was 2-fold higher than in Turkish females. Use of Framingham study in clinical assessments maintains to be a valid method in preventive approaches for development of cardiovascular diseases.
- 1 February 2011
- Published by Elsevier in Journal of Microbiology, Immunology and Infection
- Vol. 44 (1) , 21-26
Detection of immunoglobulin G antibodies to Toxoplasma gondii: Evaluation of two commercial immunoassay systems
- 1 February 2011
- Published by Elsevier in Journal of Microbiology, Immunology and Infection
- Vol. 44 (1) , 21-26
Detection of immunoglobulin G antibodies to Toxoplasma gondii: Evaluation of two commercial immunoassay systems
- Open Access
- 1 January 2011
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Medical Sciences
- Vol. 31 (6) , 1385-1391
Reference Interval Study of Rotational Thromboelastography and NATEG Test in a Healthy Group
- 1 January 2011
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Medical Sciences
- Vol. 31 (6) , 1385-1391
Open AccessReference Interval Study of Rotational Thromboelastography and NATEG Test in a Healthy Group
- 1 January 2010
- Vol. 56, 553-7
Types and frequencies of pre-analytical mistakes in the first JCI:2002 accredited hospital in Turkey.
In light of increasing attention focused on patient safety and the need to reduce laboratory mistakes, it is crucial for clinical laboratories to collect statics on error rates over the whole testing cycle, particularly on the pre-analytical phase. Memorial Hospital has a laboratory service providing stat and routine tests. From January 2005 to December 2007, a total of 766,095 specimens were received in our laboratory. The frequencies and types of pre-analytical errors and the potential targets for quality improvement strategies were evaluated. The relative frequencies of pre-analytical errors were ordered in a gradually decreasing trend through years; 0.50% in 2005; 0.25% in 2006 and 0.07% in 2007 (p < 0.0001; between 2005 and 2007). The most common mistake was incorrect/missing identification (42 %). We believe that the use of standardized routines and regular staff training, combined with an exchange of the existing paper-based referral management system with an electronic system, can increase the safety in the pre-analytical processes.
- 1 January 2010
- Vol. 56, 553-7
Types and frequencies of pre-analytical mistakes in the first JCI:2002 accredited hospital in Turkey.
In light of increasing attention focused on patient safety and the need to reduce laboratory mistakes, it is crucial for clinical laboratories to collect statics on error rates over the whole testing cycle, particularly on the pre-analytical phase. Memorial Hospital has a laboratory service providing stat and routine tests. From January 2005 to December 2007, a total of 766,095 specimens were received in our laboratory. The frequencies and types of pre-analytical errors and the potential targets for quality improvement strategies were evaluated. The relative frequencies of pre-analytical errors were ordered in a gradually decreasing trend through years; 0.50% in 2005; 0.25% in 2006 and 0.07% in 2007 (p < 0.0001; between 2005 and 2007). The most common mistake was incorrect/missing identification (42 %). We believe that the use of standardized routines and regular staff training, combined with an exchange of the existing paper-based referral management system with an electronic system, can increase the safety in the pre-analytical processes.