Aoyu Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Aoyu Hu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hao Liu
State Grid Henan Electric Power Research Institute, Zhengzhou 450052, China
1 shared publication - Honglu Zhu
School of New Energy, North China Electric Power University, Beijing 102206, China
1 shared publication - Ning Zhou
State Grid HeNan Electric Power Company Research Institute, Zhengzhou 450000, China
1 shared publication - Qian Sun
State Grid HeNan Electric Power Company Research Institute, Zhengzhou 450000, China
1 shared publication - Zhan'AO Tan
Beijing University of Chemical Technology
1 shared publication
Latest Publications
- Open Access
A Novel Photovoltaic Array Outlier Cleaning Algorithm Based on Sliding Standard Deviation Mutation
There is a large number of outliers in the operation data of photovoltaic (PV) array, which is caused by array abnormalities and faults, communication issues, sensor failure, and array shutdown during PV power plant operation. The outlier will reduce the accuracy of PV system performance analysis and modeling, and make it difficult for fault diagnosis of PV power plant. The conventional data cleaning method is affected by the outlier data distribution. In order to solve the above problems, this paper presents a method for identifying PV array outliers based on sliding standard deviation mutation. Considering the PV array output characteristics under actual environmental conditions, the distribution of array outliers is analyzed. Then, an outlier identification method is established based on sliding standard deviation calculation. This method can identify outliers by analyzing the degree of dispersion of the operational data. The verification part is illustrated by case study and algorithm comparison. In the case study, multiple sets of actual operating data of different inverters are cleaned, which is selected from a large grid-connected power station. The cleaning results illustrate the availability of the algorithm. Then, the comparison against the quantile-algorithm-based outlier identification method explains the effectiveness of the proposed algorithm.
Open AccessA Novel Photovoltaic Array Outlier Cleaning Algorithm Based on Sliding Standard Deviation Mutation
There is a large number of outliers in the operation data of photovoltaic (PV) array, which is caused by array abnormalities and faults, communication issues, sensor failure, and array shutdown during PV power plant operation. The outlier will reduce the accuracy of PV system performance analysis and modeling, and make it difficult for fault diagnosis of PV power plant. The conventional data cleaning method is affected by the outlier data distribution. In order to solve the above problems, this paper presents a method for identifying PV array outliers based on sliding standard deviation mutation. Considering the PV array output characteristics under actual environmental conditions, the distribution of array outliers is analyzed. Then, an outlier identification method is established based on sliding standard deviation calculation. This method can identify outliers by analyzing the degree of dispersion of the operational data. The verification part is illustrated by case study and algorithm comparison. In the case study, multiple sets of actual operating data of different inverters are cleaned, which is selected from a large grid-connected power station. The cleaning results illustrate the availability of the algorithm. Then, the comparison against the quantile-algorithm-based outlier identification method explains the effectiveness of the proposed algorithm.