MHMark A. Hayes

Mark A. Hayes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mark A. Hayes has a total of 125 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intrinsic precision for electrophysical characterization of minimized biological variance populations of bacteria using dielectrophoresis

    by Hoai Nguyen, A. K. M. Fazlul Karim Rasel, Alex McLaren, Mark A. Hayes

    Rapid and accurate pathogen identification is critical for clinical diagnostics and treatment decisions. Dielectrophoresis (DEP) in microfluidic platforms has emerged as a promising label-free technique for bacterial identification, with demonstrated capability to distinguish closely related phenotypes based on biophysical properties. This strategy has the potential to compliment and compete with culture-based identification. While previous studies have focused on understanding the fundamental mechanisms underlying these separations, a critical question for clinical translation remains unaddressed: What is the best-case measurement precision achievable by DEP technology when biological variance is minimized? To address this, we quantified the variance of dielectrophoretic response within and between three Staphylococcus epidermidis isolates (ATCC 12228, ATCC 14990, and ATCC 35984) propagated under standardized conditions to minimize heterogeneity. With bacteria populations of identical growth kinetics, cell size, zeta potential, and suspension conductivity, the electrokinetic mobility ratio variance is in the range of 7%–18% RSD. Two-isolate mixtures were prepared to study interference, which consistently exhibited onset voltages matching the lower-threshold component. Analysis of conductivity across applied voltages showed no systematic voltage-dependent measurement artifacts. These findings demonstrate that biological variance within bacterial populations does not fundamentally limit DEP-based identification strategies, supporting the continued development of microfluidic dielectrophoretic techniques for rapid pathogen identification.

  • Emerging capabilities in microscale separations and bioanalysis

    by Mark A. Hayes, Christopher Harrison, Alexandra Ros

  • Open Access

    Quantifying and Minimizing the Variance of Gradient Insulator-Based Dielectrophoresis

    by Hoai Nguyen, A. K. M. Fazlul Karim Rasel, Mark A. Hayes

    Opportunities abound in microfluidic technologies to impact how we understand extremely complex systems with many constituents which change with time and space. In these technologies, separation science plays a central role towards understanding everything from biology and healthcare to environmental monitoring to the search for life in the Solar system. Separations can amplify the capabilities of detection modalities by isolating targets and/or increasing their concentration while removing background constituents which can interfere with their sensing. In essence, separations increase the amount of information that can be gathered from a sample. The ideal features of next-generation separations capability are present in gradient insulator-based dielectrophoresis (g-iDEP), enabled by the length scale and precision of microfluidics. It acts through electric field interactions with particles, which enables unbiased (label-free) separations since all relevant particles, from atoms to cells, have an accessible response to electricity—either through linear (electrophoresis) or higher-order gradient (dielectrophoresis and related) effects. The technique isolates and concentrates, enabling improved detection function and multidimensional separations. Its foundational theoretical capabilities give it separations power on the order of 1:108, beyond the resolving power of the best mass spectrometers and ultra-high resolution spectroscopies. Experimental evidence is amassing that shows it to be a powerful tool that can resolve tiny differences in cells (antibiotic resistance versus susceptible in unlabeled paired isolates across many species) and differentiate single-point mutations in proteins. Its capabilities are still emerging, and this work aims to quantify the current practice and connect those approaches to the ultimate capabilities of the technique towards quantifying the dynamic range and resolving power of the strategy as a whole. The technique uses two methods of quantifying the electrophysical properties of the target, voltage sweep and spatial methods. The voltage sweep method is lower-resolution and serves as a search mode, while the spatial method is higher-resolution and quantifies the properties over a smaller defined range determined via the sweep method. These quantification methods are examined by collating existing experimental data, performing relevant Monte Carlo simulations, and finite element model calculations. These are summarized to understand the mechanisms currently limiting the technique, facilitate quantitative comparisons with traditional separation science capabilities in terms of resolution and dynamic range, and compare them to the theoretical limits of the strategy.

  • NanoRidge filters: Fabrication strategies and performance optimization for nano-scale microfluidic particle filtration

    by Jared P. Smithers, Jerry Sheu, Brian Richardson, Mark A. Hayes

    Filters with high throughput, minimal dead volume, and greater sensitivity to particle size are needed, which traditional benchtop filtration cannot provide. Leveraging microfabrication techniques developed by the electronics and optics industries, the filters presented here feature a unique serpentine “NanoRidge” structure, offering a continuous filtration gap spanning over three meters on a compact 4 × 14.5 mm2 footprint. This design provides more precise size filtration cut-offs and consistent flow paths compared to traditional membrane filtration systems. Despite challenges associated with glass substrate deformation impacting uniform filter gap sizes, the study provides valuable insights into the development of NanoRidge filters (NRFs) for enhancing filtration efficiency in preparatory techniques and sample analysis. This study describes the fabrication and testing of these new filter types and directly compares the performance to traditional membrane filters using the metrics of particle size cut-off (the smallest difference in particle size which can be filtered vs passed) and particle loss. The NanoRidge filters were characterized using imaging (during fabrication, post-fabrication and use, fluorescent particles captured and small molecule dye), pressure and flow measurements, and a series of particle sizes “filter or pass” studies. Particle capacity (100–250 nm) ranged from 5 × 108 to 7 × 109 in 1 ml samples at a flow rate of 100 μl/min with backpressure in the range of 1–3 Bar. The optimized fabrication procedure for the 150 nm NRF yielded a small particle recovery of 95% while also achieving a large particle filtration of 73%. High filtration efficiency was also proven in the final 60 and 80 nm NRF fabrication procedures at 96% and 91%, respectively.


  • A numerical study on microfluidic devices to maintain the concentration and purity of dielectrophoresis-induced separated fractions of analyte

    by A. K. M. Fazlul Karim Rasel, Sean L. Seyler, Mark A. Hayes

    Determining the physical and chemical properties of biologically important particles such as cells, organelles, viruses, exosomes, complexes, nucleotides, and proteins is needed to understand their function. These properties are determined with common analytical tools (mass spectrometry, cryo-EM, NMR, various spectroscopies, nucleotide sequencing, etc.) whose function can be improved when samples are pure and concentrated. Separations science plays a central role in conditioning samples, ranging from low-resolution benchtop operations like precipitations or extractions to higher-resolution chromatography and electrophoresis. In the last two decades, gradient insulator-based dielectrophoresis (g-iDEP) has emerged as a high-resolution separation technique capable of highly selective enrichment of cells, viruses, exosomes, and proteins. Specific evidence has been shown that pure homogeneous and concentrated fractions of cells and exosomes can be generated from complex mixtures. However, recovering those fractions for analysis has not been developed, limiting the technique to an analytical rather than a preparative one. Here, a finite element analysis was undertaken to identify geometries and operational parameters to efficiently remove the enriched fraction while retaining maximum concentration and providing total mass transfer. Geometric factors (e.g., side channel width and distance from the gradient-inducing gap) were studied, along with the addition of a second inlet side channel. Two flow-generating mechanisms—electroosmosis and hydrostatic pressure—were evaluated for semi-optimized device designs, including a comparison of the one- and two-inlet designs. Simulations indicate effectively one hundred percent mass transfer and a concentration increase by an order of magnitude for several device configurations and operational parameters.


  • Open Access

    Editorial Board: Electrophoresis 3–4'23

    by Blanca Lapizco‐Encinas, František Foret, Carlos García, Emanuel Carrilho, São Paulo, Yiwang Chen, Alejandro Cifuentes, Prashanta Dutta, Bohuslav Gaš, Mark A. Hayes, et al.

  • Interfacing microfluidics with information-rich detection systems for cells, bioparticles, and molecules

    by Jared P. Smithers, Mark A. Hayes

    The development of elegant and numerous microfluidic manipulations has enabled significant advances in the processing of small volume samples and the detection of minute amounts of biomaterials. Effective isolation of single cells in a defined volume as well as manipulations of complex bioparticle or biomolecule mixtures allows for the utilization of information-rich detection methods including mass spectrometry, electron microscopy imaging, and amplification/sequencing. The art and science of translating biosamples from microfluidic platforms to highly advanced, information-rich detection system is the focus of this review, where we term the translation between the microfluidics elements to the external world “off-chipping.” When presented with the challenge of presenting sub-nanoliter volumes of manipulated sample to a detection scheme, several delivery techniques have been developed for effective analysis. These techniques include spraying (electrospray, nano-electrospray, pneumatic), meniscus-defined volumes (droplets, plugs), constrained volumes (narrow channels, containers), and phase changes (deposition, freezing). Each technique has been proven effective in delivering highly defined samples from microfluidic systems to the detection elements. This review organizes and presents selective publications that illustrate the advancements of these delivery techniques with respect to the type of sample analyzed, while introducing each strategy and providing historical perspective. The publications highlighted in this review were chosen due to their significance and relevance in the development of their respective off-chip technique. Graphical abstract This review highlights advancements of delivery methods off a microfluidic chip for additional information rich detection schemes


  • Open Access

    iDEP-assisted isolation of insulin secretory vesicles

    by Mahta Barekatain, Yameng Liu, Zhongying Wang, Vadim Cherezov, Scott E. Fraser, Kate L White, Mark A. Hayes

    Organelle heterogeneity and inter-organelle associations within a single cell contribute to the limited sensitivity of current organelle separation techniques, thus hindering organelle subpopulation characterization. Here we use direct current insulator-based dielectrophoresis (DC-iDEP) as an unbiased separation method and demonstrate its capability by identifying distinct distribution patterns of insulin vesicles from pancreatic β-cells. A multiple voltage DC-iDEP strategy with increased range and sensitivity has been applied, and a differentiation factor (ratio of electrokinetic to dielectrophoretic mobility) has been used to characterize features of insulin vesicle distribution patterns. We observed a significant difference in the distribution pattern of insulin vesicles isolated from glucose-stimulated cells relative to unstimulated cells, in accordance with functional maturation of vesicles upon glucose stimulation, and interpret this to be indicative of high-resolution separation of vesicle subpopulation. DC-iDEP provides a path for future characterization of subtle biochemical differences of organelle subpopulations within any biological system.

  • Orders-of-Magnitude Larger Force Demonstrated for Dielectrophoresis of Proteins Enabling High-Resolution Separations Based on New Mechanisms

    by Yameng Liu, Mark A. Hayes

    Proteins are perhaps the most important yet frustratingly complicated and difficult class of compounds to analyze, manipulate, and use. One very attractive option to characterize and differentially concentrate proteins is dielectrophoresis, but according to accepted theory, the force on smaller particles the size of proteins is too low to overcome diffusive action. Here, three model proteins, immunoglobulin G, α-chymotrypsinogen A, and lysozyme, are shown to generate forces much larger than predicted by established theory are more consistent with new theoretical constructs, which include the dipole moment and interfacial polarizability. The forces exerted on the proteins are quantitatively measured against well-established electrophoretic and diffusive processes and differ for each. These forces are orders of magnitude larger than previously predicted and enable the selective isolation and concentration of proteins consistent with an extremely high-resolution separation and concentration system based on the higher-order electric properties. The separations occur over a small footprint, happen quickly, and can be made in series or parallel (and in any order) on simple devices.