ZWZhanjing Wu

Zhanjing Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhanjing Wu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Haisu Sun

    School of Intelligent Construction and Civil Engineering, Luoyang Institute of Science and Technology 1 , Luoyang 471023

    1 shared publication
  • Jianyang Xue

    School of Civil Engineering Xi'an University of Architecture and Technology Xi'an China

    1 shared publication
  • Jianyang Xue

    School of Civil Engineering, Xi’an University of Architecture & Technology, Xi’an 710055, China

    1 shared publication
  • Jinshuang Dong

    College of Civil Engineering and Architecture Hainan University Haikou China

    1 shared publication
  • Longfei Zhang

    College of Architecture and Civil Engineering, Kunming University 4 , Kunming 650214

    1 shared publication
  • Qiang Huang

    School of Intelligent Construction and Civil Engineering, Luoyang Institute of Science and Technology 1 , Luoyang 471023

    1 shared publication

Latest Publications

  • Open Access

    Experimental evaluation of supplemental friction dampers for torsional control of step-terrace mountain isolated structures

    by Zhanjing Wu, Zhong Tao, Longfei Zhang, Zhengjia Wu, Qiang Huang, Haisu Sun

    Step-terrace mountain (STM) isolated structures are susceptible to torsional response when eccentricity exists in the isolation layers, owing to dropped stories, multi-level foundations, and discontinuous stiffness distribution. This study experimentally investigates the use of supplemental friction dampers for torsional mitigation in eccentric STM isolated structures. Shaking-table tests were conducted using a 1:10-scale reinforced concrete STM isolated structural model. Comparative tests were performed for isolated and isolation–damping configurations under different isolation-layer eccentricity cases and seismic intensity levels. Torsional rotation, torsional displacement ratio, and relative torsional effect were adopted to evaluate the control performance of the proposed system. The results show that the supplemental friction dampers reduced the torsional response of the STM isolated structure under all investigated eccentricity configurations. Across all three tested eccentricity configurations, the supplemental friction dampers consistently reduced torsional response, with the most pronounced mitigation observed in case 2. Under increasing seismic intensity, the isolation–damping structure consistently exhibited lower torsional response than the corresponding isolated structure, while the fundamental frequency remained nearly unchanged. The supplemental dampers therefore improved torsional control without noticeably altering the global dynamic characteristics of the isolation system. The tested damper configuration corresponded to a total friction capacity of ∼13% of the total isolation-system yield force, while its equivalent secant stiffness contribution was only about 3% of the total horizontal stiffness of the isolation system. These findings provide experimental evidence for the application of supplemental friction dampers in torsional control of eccentric STM isolated structures.

  • Experimental study and numerical analysis on seismic performance of steel beam‐column damping joint in Chinese traditional style buildings

    by Yan Sui, Zhenhua He, Jianyang Xue, Zhanjing Wu

    Summary: This paper aims to research the seismic performance of steel beam‐column damping joint of Chinese traditional style building. Three specimens of steel beam‐column damping joints with the1:2.6 scale were designed and researched, which included two specimens with viscous damper and one contrast specimen without viscous damper. The experimental study was carried out by cyclic dynamic loading test. The effects of viscous dampers for the steel structure beam‐column joint in Chinese traditional style buildings are analyzed by investigating the hysteretic curves, skeleton curves, strength and stiffness degradation, ductility, overstrength factor, and energy dissipation capacity. The results show that the steel beam‐column joints of Chinese tradition style buildings with viscous damper have better energy dissipation capacity and higher bearing capacity. Based on the experiment, the nonlinear finite element analysis was conducted using the ABAQUS software. The influence of damping coefficient on the behavior of the new damping joint of Chinese tradition style buildings was obtained, and the design suggestions were presented.


  • Dynamic experimental and numerical study of double beam–column joints in modern traditional‐style steel buildings with viscous damper

    by Zhanjing Wu, Jianyang Xue, Xiaojun Ke, Yan Sui, Jinshuang Dong

    Summary: Modern traditional‐style steel (MTS) structure is an innovative architecture structure that is widely used in China. This paper explores the possibility of using viscous damper, which can be conveniently installed between beam and column, to replace “sparrow brace” at beam–column joints to improve its seismic capability. Three 1/2.6 scaled MTS double beam–column joints, one without viscous damper and two with viscous damper, were fabricated and tested under dynamic cyclic loading. The results indicated that the primary failure modes were cracking of base metal and local bucking at the beam ends. The hysteretic curve of specimens with viscous dampers was more plump than the common specimen without viscous dampers, indicating better energy dissipation capacity. The displacement ductility ratio was about 1.79–1.96, indicating the viscous damper has little effect on the ductility, whereas in plastic stage, the energy dissipation of specimens and viscous damper increased rapidly, indicating great energy dissipating function of viscous damper. Meanwhile, the results also proved that finite element analysis may stimulate and predict the mechanical behavior of MTS double beam joints with viscous dampers.