Ximena García
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ximena García has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Alfredo L. Gordon
Universidad de Concepción
25 shared publications - Romel Jiménez
Carbon and Catalysis Laboratory (CarboCat) Department of Chemical Engineering, Faculty of Engineering University of Concepción 4030000 Concepción Chile
11 shared publications - Ljubisa R. Radovic
Penn State Univ, Dept Energy & Mineral Engn, University Pk, PA 16802 USA
8 shared publications - Gina Pecchi
Facultad de Ciencias Químicas, Universidad de Concepción, Casilla 160C, Concepcion 4070386, Chile
5 shared publications Patricio Ruiz
5 shared publicationsClaudia Ulloa
Univ Concepcion, Fac Environm Sci, Environm Engn Dept, POB 160-C, Concepcion, Chile
4 shared publications
Latest Publications
- Open Access
- 17 April 2026
- Published by Elsevier in SSRN Electronic Journal
Dynamic behavior of a monolithic CO2 methanation reactor to H2 load disturbance. Experimental validation
The dynamic performance of a monolithic CO2 methanation reactor was experimentally analyzed by changing the H2 flow rate while maintaining a constant H2/CO2 ratio. The feed flow was suddenly increased by 50% after achieving the first steady state. This adjustment resulted in a rise in the peak gas temperature (hot spot) and CO2 conversion until a new steady state was achieved. No significant temporal maximum or minimum in the hot spot were observed throughout the process, and its axial displacement was minimal. The experimental findings enabled the establishment of boundary conditions and thermal characteristics for a mathematical model, which qualitatively validated its capability to represent the experimental trends observed in both steady and non-steady state. The model, however, exhibited discrepancies in the temperature profile, particularly beyond the hot spot, and predicted CO2 conversion rates higher than those observed experimentally. These differences arise from extrapolating the reaction rate to temperatures that fall outside the suitable range for the chosen kinetic expression. Furthermore, a parametric study confirmed that the predicted outcomes for temperature, CO2 conversion, and the recovery time to a new steady state depend significantly on the radial thermal conductivity of the monolith and the heat transfer coefficient between the monolith and cooling medium.
- 17 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDynamic behavior of a monolithic CO2 methanation reactor to H2 load disturbance. Experimental validation
The dynamic performance of a monolithic CO2 methanation reactor was experimentally analyzed by changing the H2 flow rate while maintaining a constant H2/CO2 ratio. The feed flow was suddenly increased by 50% after achieving the first steady state. This adjustment resulted in a rise in the peak gas temperature (hot spot) and CO2 conversion until a new steady state was achieved. No significant temporal maximum or minimum in the hot spot were observed throughout the process, and its axial displacement was minimal. The experimental findings enabled the establishment of boundary conditions and thermal characteristics for a mathematical model, which qualitatively validated its capability to represent the experimental trends observed in both steady and non-steady state. The model, however, exhibited discrepancies in the temperature profile, particularly beyond the hot spot, and predicted CO2 conversion rates higher than those observed experimentally. These differences arise from extrapolating the reaction rate to temperatures that fall outside the suitable range for the chosen kinetic expression. Furthermore, a parametric study confirmed that the predicted outcomes for temperature, CO2 conversion, and the recovery time to a new steady state depend significantly on the radial thermal conductivity of the monolith and the heat transfer coefficient between the monolith and cooling medium.
- 20 June 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 77, 769-783
Modeling the dynamic operation of a monolithic CO2 methanation reactor. Evaluation of the response to H2 load fluctuation
- 20 June 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 77, 769-783
Modeling the dynamic operation of a monolithic CO2 methanation reactor. Evaluation of the response to H2 load fluctuation
- 24 February 2023
- Published by Elsevier in Journal of Thoracic Oncology
- Vol. 18 (3) , S28-S29
PP.50 Implementation of an Institutional Lung Cancer Screening Program Using Low-Dose Computed Tomography in Argentina
- 24 February 2023
- Published by Elsevier in Journal of Thoracic Oncology
- Vol. 18 (3) , S28-S29
PP.50 Implementation of an Institutional Lung Cancer Screening Program Using Low-Dose Computed Tomography in Argentina
- Open Access
A 3D Transient CFD Simulation of a Multi-Tubular Reactor for Power to Gas Applications
A 3D stationary CFD study was conducted in our previous work, resulting in a novel reactor design methodology oriented to upgrading biogas through CO2 methanation. To enhance our design methodology incorporating relevant power to gas operational conditions, a novel transient 3D CFD modelling methodology is employed to simulate the effect of relevant dynamic disruptions on the behaviour of a tubular fixed bed reactor for biogas upgrading. Unlike 1D/2D models, this contribution implements a full 3D shell cooled methanation reactor considering real-world operational conditions. The reactor’s behaviour was analysed considering the hot-spot temperature and the outlet CH4 mole fraction as the main performance parameters. The reactor start-up and shutdown times were estimated at 330 s and 130 s, respectively. As expected, inlet feed and temperature disruptions prompted “wrong-way” behaviours. A 30 s H2 feed interruption gave rise to a transient low-temperature hot spot, which dissipated after 60 s H2 feed was resumed. A 20 K rise in the inlet temperature (523–543 K) triggered a transient low-temperature hot spot (879 to 850 K). On the contrary, a 20 K inlet temperature drop resulted in a transient high-temperature hot spot (879 to 923 K), which exposed the catalyst to its maximum operational temperature. The maximum idle time, which allowed for a warm start of the reactor, was estimated at three hours in the absence of heat sources. No significant impacts were found on the product gas quality (% CH4) under the considered disruptions. Unlike typical 1D/2D simulation works, a 3D model allowed to identify the relevant design issues like the impact of hot-spot displacement on the reactor cooling efficiency.
Open AccessA 3D Transient CFD Simulation of a Multi-Tubular Reactor for Power to Gas Applications
A 3D stationary CFD study was conducted in our previous work, resulting in a novel reactor design methodology oriented to upgrading biogas through CO2 methanation. To enhance our design methodology incorporating relevant power to gas operational conditions, a novel transient 3D CFD modelling methodology is employed to simulate the effect of relevant dynamic disruptions on the behaviour of a tubular fixed bed reactor for biogas upgrading. Unlike 1D/2D models, this contribution implements a full 3D shell cooled methanation reactor considering real-world operational conditions. The reactor’s behaviour was analysed considering the hot-spot temperature and the outlet CH4 mole fraction as the main performance parameters. The reactor start-up and shutdown times were estimated at 330 s and 130 s, respectively. As expected, inlet feed and temperature disruptions prompted “wrong-way” behaviours. A 30 s H2 feed interruption gave rise to a transient low-temperature hot spot, which dissipated after 60 s H2 feed was resumed. A 20 K rise in the inlet temperature (523–543 K) triggered a transient low-temperature hot spot (879 to 850 K). On the contrary, a 20 K inlet temperature drop resulted in a transient high-temperature hot spot (879 to 923 K), which exposed the catalyst to its maximum operational temperature. The maximum idle time, which allowed for a warm start of the reactor, was estimated at three hours in the absence of heat sources. No significant impacts were found on the product gas quality (% CH4) under the considered disruptions. Unlike typical 1D/2D simulation works, a 3D model allowed to identify the relevant design issues like the impact of hot-spot displacement on the reactor cooling efficiency.
- Open Access
A CFD Design Approach for Industrial Size Tubular Reactors for SNG Production from Biogas (CO2 Methanation)
A tubular reactor based on the disk and doughnut concept was designed as an engineering solution for biogas upgrading via CO2 methanation. CFD (Computational Fluid Dynamics) benchmarks agreed well with experimental and empirical (correlation) data, giving a maximum error of 8.5% and 20% for the chemical reaction and heat transfer models, respectively. Likewise, hot spot position was accurately predicted, with a 5% error. The methodology was used to investigate the effect of two commercially available coolants (thermal oil and molten salts) on overall reactor performance through a parametric study involving four coolant flow rates. Although molten salts did show higher heat transfer coefficients at lower coolant rates, 82% superior, it also increases, by five times, the pumping power. A critical coolant flow rate (3.5 m3/h) was found, which allows both a stable thermal operation and optimum pumping energy consumption. The adopted coolant flow range remains critical to guarantee thermal design validity in correlation-based studies. Due to the disk and doughnut configuration, coolant flow remains uniform, promoting turbulence (Re ≈ 14,000 at doughnut outlet) and maximizing heat transfer at hot spot. Likewise, baffle positioning was found critical to accommodate and reduce stagnant zones, improving the heat transfer. Finally, a reactor design is presented for SNG (Synthetic Natural Gas) production from a 150 Nm3 h−1 biogas plant.
Open AccessA CFD Design Approach for Industrial Size Tubular Reactors for SNG Production from Biogas (CO2 Methanation)
A tubular reactor based on the disk and doughnut concept was designed as an engineering solution for biogas upgrading via CO2 methanation. CFD (Computational Fluid Dynamics) benchmarks agreed well with experimental and empirical (correlation) data, giving a maximum error of 8.5% and 20% for the chemical reaction and heat transfer models, respectively. Likewise, hot spot position was accurately predicted, with a 5% error. The methodology was used to investigate the effect of two commercially available coolants (thermal oil and molten salts) on overall reactor performance through a parametric study involving four coolant flow rates. Although molten salts did show higher heat transfer coefficients at lower coolant rates, 82% superior, it also increases, by five times, the pumping power. A critical coolant flow rate (3.5 m3/h) was found, which allows both a stable thermal operation and optimum pumping energy consumption. The adopted coolant flow range remains critical to guarantee thermal design validity in correlation-based studies. Due to the disk and doughnut configuration, coolant flow remains uniform, promoting turbulence (Re ≈ 14,000 at doughnut outlet) and maximizing heat transfer at hot spot. Likewise, baffle positioning was found critical to accommodate and reduce stagnant zones, improving the heat transfer. Finally, a reactor design is presented for SNG (Synthetic Natural Gas) production from a 150 Nm3 h−1 biogas plant.
- Open Access
- 1 June 2020
- Published by Elsevier in Data in Brief
- Vol. 30, 105362
IRC data for a mechanistic route starting with H2O adsorption and finishing with H2 desorption from graphene
- 1 June 2020
- Published by Elsevier in Data in Brief
- Vol. 30, 105362
Open AccessIRC data for a mechanistic route starting with H2O adsorption and finishing with H2 desorption from graphene