Simon Tam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Simon Tam has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Benoit Gosselin
Université Laval
4 shared publications - Mounir Boukadoum
Université du Québec à Montréal
3 shared publications - Alexandre Campeau-Lecours
Université Laval
2 shared publications Alexandre Campeau-Lecours
Department of Mechanical Engineering, Université Laval, Quebec, Canada
1 shared publication- Ali Mortazavi
Department of Electrical and Computer Engineering, Universit Laval, Qubec, QC, Canada
1 shared publication - Cheikh Latyr Fall
Department of Electrical and Computer Engineering, Universit Laval, Quebec, QC, Canada
1 shared publication
Latest Publications
- 11 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (5) , 968-984
Novel Wearable HD-EMG Sensor With Shift-Robust Gesture Recognition Using Deep Learning
In this work, we present a hardware-software solution to improve the robustness of hand gesture recognition to confounding factors in myoelectric control. The solution includes a novel, full-circumference, flexible, 64-channel high-density electromyography (HD-EMG) sensor called EMaGer. The stretchable, wearable sensor adapts to different forearm sizes while maintaining uniform electrode density around the limb. Leveraging this uniformity, we propose novel array barrel-shifting data augmentation (ABSDA) approach used with a convolutional neural network (CNN), and an anti-aliased CNN (AA-CNN), that provides shift invariance around the limb for improved classification robustness to electrode movement, forearm orientation, and inter-session variability. Signals are sampled from a 4x16 HD-EMG array of electrodes at a frequency of 1 kHz and 16-bit resolution. Using data from 12 able-bodied participants, the approach is tested in response to sensor rotation, forearm rotation, and inter-session scenarios. The proposed ABSDA-CNN method improves inter-session accuracy by 25.67% on average across users for 6 gesture classes compared to conventional CNN classification. A comparison with other devices shows that this benefit is enabled by the unique design of the EMaGer array. The AA-CNN yields improvements of up to 63.05% accuracy over non-augmented methods when tested with electrode displacements ranging from -45 $^\circ$ to +45 $^\circ$ around the limb. Overall, this paper demonstrates the benefits of co-designing sensor systems, processing methods, and inference algorithms to leverage synergistic and interdependent properties to solve state-of-the-art problems.
- 11 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (5) , 968-984
Novel Wearable HD-EMG Sensor With Shift-Robust Gesture Recognition Using Deep Learning
In this work, we present a hardware-software solution to improve the robustness of hand gesture recognition to confounding factors in myoelectric control. The solution includes a novel, full-circumference, flexible, 64-channel high-density electromyography (HD-EMG) sensor called EMaGer. The stretchable, wearable sensor adapts to different forearm sizes while maintaining uniform electrode density around the limb. Leveraging this uniformity, we propose novel array barrel-shifting data augmentation (ABSDA) approach used with a convolutional neural network (CNN), and an anti-aliased CNN (AA-CNN), that provides shift invariance around the limb for improved classification robustness to electrode movement, forearm orientation, and inter-session variability. Signals are sampled from a 4x16 HD-EMG array of electrodes at a frequency of 1 kHz and 16-bit resolution. Using data from 12 able-bodied participants, the approach is tested in response to sensor rotation, forearm rotation, and inter-session scenarios. The proposed ABSDA-CNN method improves inter-session accuracy by 25.67% on average across users for 6 gesture classes compared to conventional CNN classification. A comparison with other devices shows that this benefit is enabled by the unique design of the EMaGer array. The AA-CNN yields improvements of up to 63.05% accuracy over non-augmented methods when tested with electrode displacements ranging from -45 $^\circ$ to +45 $^\circ$ around the limb. Overall, this paper demonstrates the benefits of co-designing sensor systems, processing methods, and inference algorithms to leverage synergistic and interdependent properties to solve state-of-the-art problems.
- Open Access
- 28 May 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-14
Intuitive real-time control strategy for high-density myoelectric hand prosthesis using deep and transfer learning
Myoelectric hand prostheses offer a way for upper-limb amputees to recover gesture and prehensile abilities to ease rehabilitation and daily life activities. However, studies with prosthesis users found that a lack of intuitiveness and ease-of-use in the human-machine control interface are among the main driving factors in the low user acceptance of these devices. This paper proposes a highly intuitive, responsive and reliable real-time myoelectric hand prosthesis control strategy with an emphasis on the demonstration and report of real-time evaluation metrics. The presented solution leverages surface high-density electromyography (HD-EMG) and a convolutional neural network (CNN) to adapt itself to each unique user and his/her specific voluntary muscle contraction patterns. Furthermore, a transfer learning approach is presented to drastically reduce the training time and allow for easy installation and calibration processes. The CNN-based gesture recognition system was evaluated in real-time with a group of 12 able-bodied users. A real-time test for 6 classes/grip modes resulted in mean and median positive predictive values (PPV) of 93.43% and 100%, respectively. Each gesture state is instantly accessible from any other state, with no mode switching required for increased responsiveness and natural seamless control. The system is able to output a correct prediction within less than 116 ms latency. 100% PPV has been attained in many trials and is realistically achievable consistently with user practice and/or employing a thresholded majority vote inference. Using transfer learning, these results are achievable after a sensor installation, data recording and network training/fine-tuning routine taking less than 10 min to complete, a reduction of 89.4% in the setup time of the traditional, non-transfer learning approach.
- 28 May 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-14
Open AccessIntuitive real-time control strategy for high-density myoelectric hand prosthesis using deep and transfer learning
Myoelectric hand prostheses offer a way for upper-limb amputees to recover gesture and prehensile abilities to ease rehabilitation and daily life activities. However, studies with prosthesis users found that a lack of intuitiveness and ease-of-use in the human-machine control interface are among the main driving factors in the low user acceptance of these devices. This paper proposes a highly intuitive, responsive and reliable real-time myoelectric hand prosthesis control strategy with an emphasis on the demonstration and report of real-time evaluation metrics. The presented solution leverages surface high-density electromyography (HD-EMG) and a convolutional neural network (CNN) to adapt itself to each unique user and his/her specific voluntary muscle contraction patterns. Furthermore, a transfer learning approach is presented to drastically reduce the training time and allow for easy installation and calibration processes. The CNN-based gesture recognition system was evaluated in real-time with a group of 12 able-bodied users. A real-time test for 6 classes/grip modes resulted in mean and median positive predictive values (PPV) of 93.43% and 100%, respectively. Each gesture state is instantly accessible from any other state, with no mode switching required for increased responsiveness and natural seamless control. The system is able to output a correct prediction within less than 116 ms latency. 100% PPV has been attained in many trials and is realistically achievable consistently with user practice and/or employing a thresholded majority vote inference. Using transfer learning, these results are achievable after a sensor installation, data recording and network training/fine-tuning routine taking less than 10 min to complete, a reduction of 89.4% in the setup time of the traditional, non-transfer learning approach.
- 25 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (2) , 232-243
A Fully Embedded Adaptive Real-Time Hand Gesture Classifier Leveraging HD-sEMG and Deep Learning
This paper presents a real-time fine gesture recognition system for multi-articulating hand prosthesis control, using an embedded convolutional neural network (CNN) to classify hand-muscle contractions sensed at the forearm. The sensor consists in a custom non-intrusive, compact, and easy-to-install 32-channel high-density surface electromyography (HDsEMG) electrode array, built on a flexible printed circuit board (PCB) to allow wrapping around the forearm. The sensor provides a low-noise digitization interface with wireless data transmission through an industrial, scientific and medical (ISM) radio link. An original frequency-time-space cross-domain preprocessing method is proposed to enhance gesture-specific data homogeneity and generate reliable muscle activation maps, leading to 98.15% accuracy when using a majority vote over 5 subsequent inferences by the proposed CNN. The obtained real-time gesture recognition, within 100 to 200 ms, and CNN properties show reliable and promising results to improve on the state-of-the-art of commercial hand prostheses. Moreover, edge computing using a specialized embedded artificial intelligence (AI) platform ensures reliable, secure and low latency real-time operation as well as quick and easy access to training, fine-tuning and calibration of the neural network. Co-design of the signal processing, AI algorithms and sensing hardware ensures a reliable and power-efficient embedded gesture recognition system.
- 25 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (2) , 232-243
A Fully Embedded Adaptive Real-Time Hand Gesture Classifier Leveraging HD-sEMG and Deep Learning
This paper presents a real-time fine gesture recognition system for multi-articulating hand prosthesis control, using an embedded convolutional neural network (CNN) to classify hand-muscle contractions sensed at the forearm. The sensor consists in a custom non-intrusive, compact, and easy-to-install 32-channel high-density surface electromyography (HDsEMG) electrode array, built on a flexible printed circuit board (PCB) to allow wrapping around the forearm. The sensor provides a low-noise digitization interface with wireless data transmission through an industrial, scientific and medical (ISM) radio link. An original frequency-time-space cross-domain preprocessing method is proposed to enhance gesture-specific data homogeneity and generate reliable muscle activation maps, leading to 98.15% accuracy when using a majority vote over 5 subsequent inferences by the proposed CNN. The obtained real-time gesture recognition, within 100 to 200 ms, and CNN properties show reliable and promising results to improve on the state-of-the-art of commercial hand prostheses. Moreover, edge computing using a specialized embedded artificial intelligence (AI) platform ensures reliable, secure and low latency real-time operation as well as quick and easy access to training, fine-tuning and calibration of the neural network. Co-design of the signal processing, AI algorithms and sensing hardware ensures a reliable and power-efficient embedded gesture recognition system.
- 7 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11624-11633
Detection of Neuromuscular Activity Using New Non-Invasive and Flexible Multimaterial Fiber Dry-Electrodes
A new non-invasive and flexible sensor was fabricated to monitor the muscular activity of upper body muscles. It consists of a dry electrode made of multimaterial metal-polymerglass hollow-core fiber electrodes connected to a custom made signal acquisition platform. This fiber electrode only adds a negligible contribution to the recording systems internal noise (7.626 μV peak-to-peak and 1.234 μV RMS; recording system noise: 6.901 μV peak-to-peak and 1.205 μV RMS). Surface electromyograms (sEMGs) of the biceps bracci and trapezius muscles were recorded during maximal voluntary contractions using the new sensor and compared to that obtained with medical grade commercial sensors. Frequency content and time domain analysis show that the new flexible sensor performs similarly to commercial devices in terms of sEMG signal amplitude discrimination and frequency shift evaluation during the development of muscle fatigue. The advantage of the new sensor is the high flexibility of the fibers allowing their easy integration into stretchable garments without compromising the user’s comfort. This will lead to the development of a new generation of smart textile with large application for telemedicine and assistive devices.
- 7 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11624-11633
Detection of Neuromuscular Activity Using New Non-Invasive and Flexible Multimaterial Fiber Dry-Electrodes
A new non-invasive and flexible sensor was fabricated to monitor the muscular activity of upper body muscles. It consists of a dry electrode made of multimaterial metal-polymerglass hollow-core fiber electrodes connected to a custom made signal acquisition platform. This fiber electrode only adds a negligible contribution to the recording systems internal noise (7.626 μV peak-to-peak and 1.234 μV RMS; recording system noise: 6.901 μV peak-to-peak and 1.205 μV RMS). Surface electromyograms (sEMGs) of the biceps bracci and trapezius muscles were recorded during maximal voluntary contractions using the new sensor and compared to that obtained with medical grade commercial sensors. Frequency content and time domain analysis show that the new flexible sensor performs similarly to commercial devices in terms of sEMG signal amplitude discrimination and frequency shift evaluation during the development of muscle fatigue. The advantage of the new sensor is the high flexibility of the fibers allowing their easy integration into stretchable garments without compromising the user’s comfort. This will lead to the development of a new generation of smart textile with large application for telemedicine and assistive devices.
- 1 November 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 9-12
A 45nm 8-core enterprise Xeon® processor
A 2.3 B transistors, 8-core, 16-thread 64-bit Xeon® EX processor with a 24 MB shared L3 cache was implemented in a 45 nm 9-metal process. Multiple clock and voltage domains are employed to reduce power consumption. Long channel devices and cache sleep mode are used to minimize leakage. Core and cache recovery improve manufacturing yields and enable multiple product flavors using the same silicon die and package. The disabled blocks are both clock and power gated to minimize their power consumption. Idle power is reduced by shutting off the un-terminated I/O links and shedding phases in the voltage regulator to improve the power conversion efficiency.
- 1 November 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 9-12
A 45nm 8-core enterprise Xeon® processor
A 2.3 B transistors, 8-core, 16-thread 64-bit Xeon® EX processor with a 24 MB shared L3 cache was implemented in a 45 nm 9-metal process. Multiple clock and voltage domains are employed to reduce power consumption. Long channel devices and cache sleep mode are used to minimize leakage. Core and cache recovery improve manufacturing yields and enable multiple product flavors using the same silicon die and package. The disabled blocks are both clock and power gated to minimize their power consumption. Idle power is reduced by shutting off the un-terminated I/O links and shedding phases in the voltage regulator to improve the power conversion efficiency.