CPCarmen Porto

Carmen Porto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carmen Porto has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    EMM Project—LD GRIDS: Design of a Charged Dust Analyser for Moon Exploration

    by Diego Scaccabarozzi, Abdelrahman Mohamed Ragab M. Ahmed, Andrea Appiani, Bortolino Saggin, Carmen Porto, Francesca Esposito

    This work presents a comparative design of the sensing elements for the Lunar Dust GRID System (LD GRIDS), a dust analyser conceived to measure charged particles on future lunar missions. LD GRIDS replaces traditional electrodes with continuous conductive grids, i.e., the sensing elements of the instrument, which are able to collect induced charge when charged particles pass through them. The investigation focuses on evaluating the influence of various grid geometrical parameters (size, thickness, and patterns) on the sensor’s performance, either from an electrical or a mechanical perspective. All simulations were carried out using off-the-shelf numerical modelling software, where electrostatic simulation (i.e., induction performance), modal analysis, and quasi-static structural responses under a high acceleration quasi-static load were examined. The results indicate that while grids with round patterns tend to produce a higher induced charge, they also experience higher localised stresses compared to square pattern ones. Moreover, grid size does not significantly affect the instrument sensitivity, whereas increasing the grid thickness significantly reduces peak stresses, with only minor effects on electrostatic performance. Overall, the findings provided valuable insights for optimising the LD GRIDS design, aimed at balancing either electrostatic sensitivity or mechanical resistance, facing the harsh lunar environment.


  • Open Access

    Structural Optimization of MicroMED Dust Analyzer

    by Marco Giovanni Corti, Bortolino Saggin, Francesca Esposito, Gabriele Franzese, Carmen Porto, Giuseppe Mongelluzzo, Fabio Cozzolino, Diego Scaccabarozzi

    This research work describes the structural optimization of the MicroMED Dust Analyzer, an Optical Particle Counter developed for the ESA ExoMars 2022 mission. Topology Optimization, a non-conventional design technique was adopted to obtain a lighter component, a valuable achievement for aerospace and space scientific instruments design. In particular, two solutions for the instrument optical bench were proposed and assessed relying on a classical finite element approach, comparing the improved performance with the current design. The optimization outcome proved the adopted design workflow robustness and provided promising results in view of a possible mechanical design enhancement of the MicroMED Dust Analyzer instrument. Indeed, a mass budget saving of about 55% of the considered design domain was achieved, and the dynamic behaviour of the optical bench was improved by up to 50% of the first natural frequency value. Finally, a mockup of the lightened optical bench was manufactured, and the redesign effectiveness was proven by comparing the numerical mechanical resonances with the ones obtained experimentally. An error smaller than 5% was found on the first natural frequency, validating the performed optimization approach.


  • Open Access

    Design and CFD Analysis of the Fluid Dynamic Sampling System of the “MicroMED” Optical Particle Counter

    by Giuseppe Mongelluzzo, Francesca Esposito, Fabio Cozzolino, Gabriele Franzese, Alan Cosimo Ruggeri, Carmen Porto, Cesare Molfese, Diego Scaccabarozzi, Bortolino Saggin

    MicroMED is an optical particle counter that will be part of the ExoMars 2020 mission. Its goal is to provide the first ever in situ measurements of both size distribution and concentration of airborne Martian dust. The instrument samples Martian air, and it is based on an optical system that illuminates the sucked fluid by means of a collimated laser beam and detects embedded dust particles through their scattered light. By analyzing the scattered light profile, it is possible to obtain information about the dust grain size and speed. To do that, MicroMED’s fluid dynamic design should allow dust grains to cross the laser-illuminated sensing volume. The instrument’s Elegant Breadboard was previously developed and tested, and Computational Fluid Dynamic (CFD) analysis enabled determining its criticalities. The present work describes how the design criticalities were solved by means of a CFD simulation campaign. At the same time, it was possible to experimentally validate the results of the analysis. The updated design was then implemented to MicroMED’s Flight Model.