Mustafa Kocacikli
Mustafa Kocacikli has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Fatma Güneş
Faculty of Dentistry, Department of Prosthodontics, Gazi University, Ankara, Turkey
2 shared publications - A.DIlek Nalbant
GAZİ ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, DİŞ HEKİMLİĞİ PR
1 shared publication - Ayşe HANÇER GÖYMEN
GAZİ ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, DİŞ HEKİMLİĞİ PR
1 shared publication Caner Yilmaz
Professor, Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey
1 shared publication- Cengiz Haluk Bodur
GAZİ ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ
1 shared publication - Esma Başak Gül Aygün
ÇUKUROVA ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, KLİNİK BİLİMLER BÖLÜMÜ, PROTETİK DİŞ TEDAVİSİ ANABİLİM DALI, PROTETİK DİŞ TEDAVİSİ BİLİM DALI
1 shared publication
Latest Publications
- Open Access
- 22 August 2025
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 12 (2) , 321-325
Prosthetic Rehabilitation in Partially Edentulous Children with Papillon-Lefèvre Syndrome: Two Case Reports
Papillon-Lefèvre syndrome (PLS) is a rare autosomal recessive disease characterized by palmoplantar keratosis and early-onset severe periodontitis. This disease affects both primary and permanent teeth, causing premature tooth loss. Various etiological factors are associated with PLS, including genetic mutations, immunological changes, and bacterial effects. The genetic defect associated with PLS has been shown to result from a mutation in the Cathepsin C gene, located on the long arm of chromosome 11 (11q14). Removable prostheses allow changes during the growth and development of the jaw bones in PLS patients, providing the function and aesthetics that are lost until the jaw development is complete. These case reports include two siblings (7-year-old boy and 11-year-old girl) with PLS and their prosthetic rehabilitation with partial removable prostheses with a multidisciplinary approach. Routine check-ups of the patients every three months have been continuing for approximately 6 months.
- 22 August 2025
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 12 (2) , 321-325
Open AccessProsthetic Rehabilitation in Partially Edentulous Children with Papillon-Lefèvre Syndrome: Two Case Reports
Papillon-Lefèvre syndrome (PLS) is a rare autosomal recessive disease characterized by palmoplantar keratosis and early-onset severe periodontitis. This disease affects both primary and permanent teeth, causing premature tooth loss. Various etiological factors are associated with PLS, including genetic mutations, immunological changes, and bacterial effects. The genetic defect associated with PLS has been shown to result from a mutation in the Cathepsin C gene, located on the long arm of chromosome 11 (11q14). Removable prostheses allow changes during the growth and development of the jaw bones in PLS patients, providing the function and aesthetics that are lost until the jaw development is complete. These case reports include two siblings (7-year-old boy and 11-year-old girl) with PLS and their prosthetic rehabilitation with partial removable prostheses with a multidisciplinary approach. Routine check-ups of the patients every three months have been continuing for approximately 6 months.
- Open Access
- 11 July 2025
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 1 (1) , 355-369
Biomechanical Evaluation of Anterior Implant-Supported Fixed Bridges Combined with Distal-Extension Removable Partial Dentures
This study compared the biomechanical performance of anterior two implant-supported fixed prostheses combined with distal-extension removable partial dentures (DERPDs) classified as Mandibular Kennedy Class I, incorporating metal clasps and extracoronal precision attachments, against conventional Locator®- and bar-attached implant overdenture prostheses under vertical and oblique bilateral posterior biting forces using three-dimensional finite element analysis. Four prosthetic designs with different retention systems were analyzed: an overdenture with a Locator® attachment, an overdenture with a bar attachment, an anterior implant-supported fixed bridge retaining a removable partial denture with clasp retention, and an anterior implant-supported fixed bridge retaining a removable partial denture with a precision attachment. Stress values and distributions were compared among the models using three-dimensional (3D) finite element analysis (FEA). Clasp attachments exhibited the lowest stress concentrations, while precision attachments showed the highest stress values. Overdentures with bar attachments demonstrated higher stress concentrations compared to Locator® attachments. Clasp-type attachments induced less stress on implants and peri-implant tissues while causing greater posterior tissue stress compared to extracoronal precision attachments in DERPDs. It can be considered a viable treatment for patients seeking an anterior implant-supported fixed bridge for esthetic and psychological reasons, and this can increase the patient's self-confidence.
- 11 July 2025
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 1 (1) , 355-369
Open AccessBiomechanical Evaluation of Anterior Implant-Supported Fixed Bridges Combined with Distal-Extension Removable Partial Dentures
This study compared the biomechanical performance of anterior two implant-supported fixed prostheses combined with distal-extension removable partial dentures (DERPDs) classified as Mandibular Kennedy Class I, incorporating metal clasps and extracoronal precision attachments, against conventional Locator®- and bar-attached implant overdenture prostheses under vertical and oblique bilateral posterior biting forces using three-dimensional finite element analysis. Four prosthetic designs with different retention systems were analyzed: an overdenture with a Locator® attachment, an overdenture with a bar attachment, an anterior implant-supported fixed bridge retaining a removable partial denture with clasp retention, and an anterior implant-supported fixed bridge retaining a removable partial denture with a precision attachment. Stress values and distributions were compared among the models using three-dimensional (3D) finite element analysis (FEA). Clasp attachments exhibited the lowest stress concentrations, while precision attachments showed the highest stress values. Overdentures with bar attachments demonstrated higher stress concentrations compared to Locator® attachments. Clasp-type attachments induced less stress on implants and peri-implant tissues while causing greater posterior tissue stress compared to extracoronal precision attachments in DERPDs. It can be considered a viable treatment for patients seeking an anterior implant-supported fixed bridge for esthetic and psychological reasons, and this can increase the patient's self-confidence.
- 25 December 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (3) , 611-617
Dental İmplantolojide Polietereterketon (PEEK): Geleneksel Derleme
Günümüz diş hekimliğinde estetik restorasyonlara sürekli artan ilgiyle doğal diş yapısına benzer, biyouyumlu, iyi mekanik ve fiziksel özelliklere sahip metal içermeyen restorasyonlar daha sıklıkla tercih edilmektedir. Bu materyallerden biri olan termoplastik polimer yapısındaki Polietereterketon (PEEK) diş hekimliğinde kullanımı hızla yaygınlaşmaya başlamıştır. PEEK, keton ve eter fonksiyonel grupları ile birbirine bağlı aromatik halka ve amorf-kristal fazdan oluşan iki fazlı doğrusal zincir yapısına sahip, 1.3-1.5 g/cm3 yoğunlukta yarı kristalli termoplastik bir homopolimerdir. PEEK materyalinin biyouyumlu olması, elastik modülünün kemiğe daha yakın olması, şok absorpsiyonu, korozyona uğramaması, yüksek aşınma ve kırılma direncine sahip olması, üstün cilalanabilir özelliği ile plak tutulumun düşük olması ve metal restorasyonlara göre daha hafif bir materyal olması gibi özelliklere sahiptir. PEEK materyali, termal özellikleri nedeniyle insan vücudunda stabil kalmaktadır. Yüksek ısıya karşı dirençlidir ve birçok sterilizasyon yöntemine uygundur. Kimyasal olarak inert bir materyaldir. Bu sebeple diğer materyallere düşük reaksiyon gösterir ve birçok geleneksel çözeltide çözünmemektedir. PEEK materyaline karşı alerjik reaksiyon gelişme oranı düşüktür. Bu nedenle metal alerjisine sahip hastalar için iyi bir alternatiftir. Bu materyal diş hekimliğinde; implant materyali, implant abutment materyali, implant üstü dijital ölçü postu olarak, implant destekli overdenture protezlerde hassas bağlantı parçası olarak, implant üstü hibrit protezlerde alt yapı materyali, iyileşme başlığı materyali, sabit protezlerde alt yapı materyali, geçici kron materyali, hareketli protezlerde ana bağlayıcı ve kroşe materyali, okluzal splint materyali olarak kullanılabilmektedir. Anahtar Kelimeler: Diş İmplantları, Diş Protezi, Polietereterketon
- 25 December 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (3) , 611-617
Dental İmplantolojide Polietereterketon (PEEK): Geleneksel Derleme
Günümüz diş hekimliğinde estetik restorasyonlara sürekli artan ilgiyle doğal diş yapısına benzer, biyouyumlu, iyi mekanik ve fiziksel özelliklere sahip metal içermeyen restorasyonlar daha sıklıkla tercih edilmektedir. Bu materyallerden biri olan termoplastik polimer yapısındaki Polietereterketon (PEEK) diş hekimliğinde kullanımı hızla yaygınlaşmaya başlamıştır. PEEK, keton ve eter fonksiyonel grupları ile birbirine bağlı aromatik halka ve amorf-kristal fazdan oluşan iki fazlı doğrusal zincir yapısına sahip, 1.3-1.5 g/cm3 yoğunlukta yarı kristalli termoplastik bir homopolimerdir. PEEK materyalinin biyouyumlu olması, elastik modülünün kemiğe daha yakın olması, şok absorpsiyonu, korozyona uğramaması, yüksek aşınma ve kırılma direncine sahip olması, üstün cilalanabilir özelliği ile plak tutulumun düşük olması ve metal restorasyonlara göre daha hafif bir materyal olması gibi özelliklere sahiptir. PEEK materyali, termal özellikleri nedeniyle insan vücudunda stabil kalmaktadır. Yüksek ısıya karşı dirençlidir ve birçok sterilizasyon yöntemine uygundur. Kimyasal olarak inert bir materyaldir. Bu sebeple diğer materyallere düşük reaksiyon gösterir ve birçok geleneksel çözeltide çözünmemektedir. PEEK materyaline karşı alerjik reaksiyon gelişme oranı düşüktür. Bu nedenle metal alerjisine sahip hastalar için iyi bir alternatiftir. Bu materyal diş hekimliğinde; implant materyali, implant abutment materyali, implant üstü dijital ölçü postu olarak, implant destekli overdenture protezlerde hassas bağlantı parçası olarak, implant üstü hibrit protezlerde alt yapı materyali, iyileşme başlığı materyali, sabit protezlerde alt yapı materyali, geçici kron materyali, hareketli protezlerde ana bağlayıcı ve kroşe materyali, okluzal splint materyali olarak kullanılabilmektedir. Anahtar Kelimeler: Diş İmplantları, Diş Protezi, Polietereterketon
- 25 December 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (3) , 605-610
Tam Protezlerin Güncel Üretim Teknikleri: Geleneksel Derleme
Tam protezler günümüzde hala sıklıkla kullanılan hareketli protezlerdendir. Hareketli tam protezlerin üretimi için geleneksel yaklaşımın bazı dezavantajları bulunmaktadır. Çok sayıda klinik ve laboratuvar aşamasının bulunması, zaman alıcı olması ve yoğun emek sarf edilmesinin gerekmesi bunlardan birkaçıdır. Ayrıca tüm bu klinik ve laboratuvar aşamalarının manuel olarak gerçekleştirildiği göz önüne alınırsa hazırlanan protezlerde optimal kaliteyi sağlamak oldukça zordur. Tam protezlerde kaide materyali olarak en çok tercih edilen akrilik rezin, polimetil metaakrilattır. Bu rezinin kolay onarımı ve maliyetinin düşük olması gibi avantajları olmasına rağmen polimerizasyon büzülmesine bağlı olarak ortaya çıkan boyutsal değişimi ise en büyük dezavantajıdır. Bu deformasyonlardan kaçınmak için birçok muflalama tekniği geliştirilmiş olsa da istenilen düzeyde bir başarı sağlanamamış olması araştırmacıları başka teknik arayışlarına yönlendirmiş ve bu yüzden tam protezlerin yapımında daha fazla tekniğin optimizasyonunun klinik pratiğe fayda sağlayacağı düşünülmüştür. Dijital diş hekimliğindeki güncel gelişmeler tam protez tedavi yöntemlerini ve üretimlerini etkilemeye başlamıştır. Modern teknolojinin tam protezlerin üretimine olan entegrasyonuyla fabrikasyon prosedürlerinde farklılıklar ortaya çıkmıştır. Dijital iş akışı için yayınlarda önerilen adımlar oldukça çeşitlilik göstermektedir. Yeni teknolojiler hem hekimler hem de teknisyenler için özel bilgi ve beceriler gerektirirken, vasıflı el işçiliğine olan ihtiyacı ise azaltmıştır. Bu derlemenin amacı tam protezlerin geleneksel ve dijital tekniklerle üretimi ile ilgili mevcut literatürü pekiştirmek, klinik ve laboratuvar aşamalarının mevcut dijital iş akışlarını özetlemek, dijital alternatiflerin aşamalarını açıklamak ve bunların avantajlarını ve sınırlamalarını tartışmaktır.
- 25 December 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (3) , 605-610
Tam Protezlerin Güncel Üretim Teknikleri: Geleneksel Derleme
Tam protezler günümüzde hala sıklıkla kullanılan hareketli protezlerdendir. Hareketli tam protezlerin üretimi için geleneksel yaklaşımın bazı dezavantajları bulunmaktadır. Çok sayıda klinik ve laboratuvar aşamasının bulunması, zaman alıcı olması ve yoğun emek sarf edilmesinin gerekmesi bunlardan birkaçıdır. Ayrıca tüm bu klinik ve laboratuvar aşamalarının manuel olarak gerçekleştirildiği göz önüne alınırsa hazırlanan protezlerde optimal kaliteyi sağlamak oldukça zordur. Tam protezlerde kaide materyali olarak en çok tercih edilen akrilik rezin, polimetil metaakrilattır. Bu rezinin kolay onarımı ve maliyetinin düşük olması gibi avantajları olmasına rağmen polimerizasyon büzülmesine bağlı olarak ortaya çıkan boyutsal değişimi ise en büyük dezavantajıdır. Bu deformasyonlardan kaçınmak için birçok muflalama tekniği geliştirilmiş olsa da istenilen düzeyde bir başarı sağlanamamış olması araştırmacıları başka teknik arayışlarına yönlendirmiş ve bu yüzden tam protezlerin yapımında daha fazla tekniğin optimizasyonunun klinik pratiğe fayda sağlayacağı düşünülmüştür. Dijital diş hekimliğindeki güncel gelişmeler tam protez tedavi yöntemlerini ve üretimlerini etkilemeye başlamıştır. Modern teknolojinin tam protezlerin üretimine olan entegrasyonuyla fabrikasyon prosedürlerinde farklılıklar ortaya çıkmıştır. Dijital iş akışı için yayınlarda önerilen adımlar oldukça çeşitlilik göstermektedir. Yeni teknolojiler hem hekimler hem de teknisyenler için özel bilgi ve beceriler gerektirirken, vasıflı el işçiliğine olan ihtiyacı ise azaltmıştır. Bu derlemenin amacı tam protezlerin geleneksel ve dijital tekniklerle üretimi ile ilgili mevcut literatürü pekiştirmek, klinik ve laboratuvar aşamalarının mevcut dijital iş akışlarını özetlemek, dijital alternatiflerin aşamalarını açıklamak ve bunların avantajlarını ve sınırlamalarını tartışmaktır.
- Open Access
- 27 April 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (1) , 48-56
IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES
Background: In order to ensure sufficient resistance against functional forces for dentin, which is severely weakened by excessive material loss in single-root single-canal teeth with previous root canal treatment, maximum retention and resistance must be the target. The main purpose of this study is to evaluate the shear rupture resistance of the chosen three kinds of posts placed in the teeth roots, against forces that could occur in the replicated mouth. Methods: Freshly extracted 45 teeth -maxillary canin and maxillary central- have been used in our study. Crown portion of the tooth was removed by cutting away 1 mm over the enamel cement junction. Root canals were obturated with a lateral condensation technique using AH-26 and gutta percha sealer. In the study, 15 specimens each from Flexi-Post, Cosmopost, and FRC Postec post systems have been placed in sockets opened down through teeth by using specific burs for each system. A dual cured composite cement (Variolink II low viscosity) was used to bind posts. Prepared specimens were put in steel hose by using acrylic resin. Standardized core material (Coradent) was applied onto top side of posts, and steel hoses were connected to Lloyd test instrument with an angle of 45 degrees. A force with a speed of 1 mm/min was applied to the specimens. Compression shear rupture values were recorded and One Way ANOVA and Kruskall-Wallis variance analyses were conducted for statistical evaluation. Results and Conclusion: Highest values were obtained in Flexi-Post group. FRC Postec was the second, and Cosmopost had the lowest strength values. However, all the systems provided adequate resistance against forces that could occur in the mouth, hence it was concluded that they can be utilized clinically. Key words: posts and cores, post system, prefabricated post systems
- 27 April 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (1) , 48-56
Open AccessIN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES
Background: In order to ensure sufficient resistance against functional forces for dentin, which is severely weakened by excessive material loss in single-root single-canal teeth with previous root canal treatment, maximum retention and resistance must be the target. The main purpose of this study is to evaluate the shear rupture resistance of the chosen three kinds of posts placed in the teeth roots, against forces that could occur in the replicated mouth. Methods: Freshly extracted 45 teeth -maxillary canin and maxillary central- have been used in our study. Crown portion of the tooth was removed by cutting away 1 mm over the enamel cement junction. Root canals were obturated with a lateral condensation technique using AH-26 and gutta percha sealer. In the study, 15 specimens each from Flexi-Post, Cosmopost, and FRC Postec post systems have been placed in sockets opened down through teeth by using specific burs for each system. A dual cured composite cement (Variolink II low viscosity) was used to bind posts. Prepared specimens were put in steel hose by using acrylic resin. Standardized core material (Coradent) was applied onto top side of posts, and steel hoses were connected to Lloyd test instrument with an angle of 45 degrees. A force with a speed of 1 mm/min was applied to the specimens. Compression shear rupture values were recorded and One Way ANOVA and Kruskall-Wallis variance analyses were conducted for statistical evaluation. Results and Conclusion: Highest values were obtained in Flexi-Post group. FRC Postec was the second, and Cosmopost had the lowest strength values. However, all the systems provided adequate resistance against forces that could occur in the mouth, hence it was concluded that they can be utilized clinically. Key words: posts and cores, post system, prefabricated post systems
- Open Access
- 26 March 2023
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 26 (1) , 87-96
General Consideration of Post Systems
More often than not pulpless teeth remain relatively intact after conservative endodontic treatment. Although it hasn't been shown that endodontically treated teeth are more brittle than healthy ones, pulpless teeth are known to crack during mastication. As a result of this known phenomenon, dental professionals have been looking for strategies to prevent pulpless teeth from breaking. Restoration and reinforcement of pulpless teeth is a crucial preventative step in endodontic therapy. A post is cemented into the root canal to reinforce a healthy endodontically treated tooth. The post is supposed to reinforce the tooth and keep it from breaking. A widely used technique for repairing teeth that have undergone endodontic treatment is post and cores. Retention applied onto the root thorough final restoration using the post and core restoration as a substructure. Therefore, post placement in the root is crucial. In order to ensure retention for a fixed restoration, endodontically treated teeth are frequently treated with posts and cores. Teeth that had gone through endodontic treatment often suffer from severe coronal damage. In order to ensure retention for full or partial coverage restoration, these teeth may require a coronal substructure or core for retention of a full or partial bonding restoration. Generally, primary retention feature of a core is an intraradicular post. Posts and cores are routinely used for endodontical teeth restoration. This article provides a review presentation about utilization of post systems on the pulpless tooth.
- 26 March 2023
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 26 (1) , 87-96
Open AccessGeneral Consideration of Post Systems
More often than not pulpless teeth remain relatively intact after conservative endodontic treatment. Although it hasn't been shown that endodontically treated teeth are more brittle than healthy ones, pulpless teeth are known to crack during mastication. As a result of this known phenomenon, dental professionals have been looking for strategies to prevent pulpless teeth from breaking. Restoration and reinforcement of pulpless teeth is a crucial preventative step in endodontic therapy. A post is cemented into the root canal to reinforce a healthy endodontically treated tooth. The post is supposed to reinforce the tooth and keep it from breaking. A widely used technique for repairing teeth that have undergone endodontic treatment is post and cores. Retention applied onto the root thorough final restoration using the post and core restoration as a substructure. Therefore, post placement in the root is crucial. In order to ensure retention for a fixed restoration, endodontically treated teeth are frequently treated with posts and cores. Teeth that had gone through endodontic treatment often suffer from severe coronal damage. In order to ensure retention for full or partial coverage restoration, these teeth may require a coronal substructure or core for retention of a full or partial bonding restoration. Generally, primary retention feature of a core is an intraradicular post. Posts and cores are routinely used for endodontical teeth restoration. This article provides a review presentation about utilization of post systems on the pulpless tooth.
- 27 January 2023
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 46 (3) , 135-140
An alternative technique by using digital photography and UV printing for fabricating a custom made ocular prosthesis
A person becomes disabled when they lose any of their sensory organs, the eye being one of the most delicate. Loss of an eye can happen due to different reasons and can be restored using different materials and strategies. Ocular defects and congenital deformations show up as a result of tumors or injury. For the most part, fabricated eyes are accessible as ocular prostheses. This method describes how to create a custom ocular prosthesis using a digital photo and UV printing. The greatest esthetically pleasing results are also achieved using this production method, which does not necessitate painting or color-selecting expertise. Both psychologically and esthetically, the patient was satisfied.
- 27 January 2023
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 46 (3) , 135-140
An alternative technique by using digital photography and UV printing for fabricating a custom made ocular prosthesis
A person becomes disabled when they lose any of their sensory organs, the eye being one of the most delicate. Loss of an eye can happen due to different reasons and can be restored using different materials and strategies. Ocular defects and congenital deformations show up as a result of tumors or injury. For the most part, fabricated eyes are accessible as ocular prostheses. This method describes how to create a custom ocular prosthesis using a digital photo and UV printing. The greatest esthetically pleasing results are also achieved using this production method, which does not necessitate painting or color-selecting expertise. Both psychologically and esthetically, the patient was satisfied.
- 18 November 2019
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 43 (5) , 343-347
Three-dimensional printing technologies in the fabrication of maxillofacial prosthesis: A case report
Purpose: Patients with maxillofacial deformities always seek for aesthetic prosthesis. Recently, three-dimensional printing technologies have been used for dental treatments on such patients. Case report: A 24-year-old man reported to the Department of Prosthodontics for replacement of his missing right ear induced by a trauma. A magnet-retained auricular prosthesis was planned for the patient. Three-dimensional scanning was performed on the healthy side by using a three-dimensional optical scanner and the data were mirrored. The mirrored image was then imported to a software and a virtual model of the future prosthesis was obtained for the defect side. A three-dimensional printer was used to fabricate a negative mold for the mirrored image by using additive manufacturing. Initially, an impression of the defect side was made; then, the cast model was obtained in a dental flask. Magnets of the prosthesis were inserted to the acrylic resin framework on the cast model. Room temperature vulcanized silicone elastomer was mixed and poured into the three-dimensionally fabricated mold. Then, the flask was placed over the negative mold firmly. After polymerization of the silicone, the auricular prosthesis was delivered to the patient and the patient was instructed to clean the prosthesis daily. Conclusions: Three-dimensional printing technology was used for the fabrication of the patient’s missing ear. This method eliminated the conventional laboratory steps and reduced the number of stages of the fabrication of a silicone prosthesis. The negative mold of the defect side allowed us a direct fabrication of the silicone prosthesis without a need for waxing or flasking procedures.
- 18 November 2019
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 43 (5) , 343-347
Three-dimensional printing technologies in the fabrication of maxillofacial prosthesis: A case report
Purpose: Patients with maxillofacial deformities always seek for aesthetic prosthesis. Recently, three-dimensional printing technologies have been used for dental treatments on such patients. Case report: A 24-year-old man reported to the Department of Prosthodontics for replacement of his missing right ear induced by a trauma. A magnet-retained auricular prosthesis was planned for the patient. Three-dimensional scanning was performed on the healthy side by using a three-dimensional optical scanner and the data were mirrored. The mirrored image was then imported to a software and a virtual model of the future prosthesis was obtained for the defect side. A three-dimensional printer was used to fabricate a negative mold for the mirrored image by using additive manufacturing. Initially, an impression of the defect side was made; then, the cast model was obtained in a dental flask. Magnets of the prosthesis were inserted to the acrylic resin framework on the cast model. Room temperature vulcanized silicone elastomer was mixed and poured into the three-dimensionally fabricated mold. Then, the flask was placed over the negative mold firmly. After polymerization of the silicone, the auricular prosthesis was delivered to the patient and the patient was instructed to clean the prosthesis daily. Conclusions: Three-dimensional printing technology was used for the fabrication of the patient’s missing ear. This method eliminated the conventional laboratory steps and reduced the number of stages of the fabrication of a silicone prosthesis. The negative mold of the defect side allowed us a direct fabrication of the silicone prosthesis without a need for waxing or flasking procedures.
- Open Access
- 1 January 2010
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Medical Sciences
- Vol. 30 (5) , 1750-1755
Fabricating Toe Prostheses Using 3-D Modeling Technique: Case Report
This article describes a technique for making toe prostheses using CAD-CAM technology and a rapid prototyping machine. A laser scanner was used to develop an integrated 3D digital image of the existing toe of a patient subjected to toe ablative surgery. The image was mirrored and used to manufacture the solid toe cast by means of a rapid prototyping machine. Subsequently, the definitive prosthesis was obtained through conventional procedures. Recent studies have focused on computer-assisted rapid prototyping machines to sculpture facial prostheses. Several techniques have been reported to fabricate a mirror-image wax cast for maxillofacial prostheses; however these techniques are costly and may require more time than manual fabrication. Several research protocols have proposed technical computer assisted solutions, however this article describes a simple, inexpensive, and repeatable method of obtaining a definitive wax cast of toe prosthesis.
- 1 January 2010
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Medical Sciences
- Vol. 30 (5) , 1750-1755
Open AccessFabricating Toe Prostheses Using 3-D Modeling Technique: Case Report
This article describes a technique for making toe prostheses using CAD-CAM technology and a rapid prototyping machine. A laser scanner was used to develop an integrated 3D digital image of the existing toe of a patient subjected to toe ablative surgery. The image was mirrored and used to manufacture the solid toe cast by means of a rapid prototyping machine. Subsequently, the definitive prosthesis was obtained through conventional procedures. Recent studies have focused on computer-assisted rapid prototyping machines to sculpture facial prostheses. Several techniques have been reported to fabricate a mirror-image wax cast for maxillofacial prostheses; however these techniques are costly and may require more time than manual fabrication. Several research protocols have proposed technical computer assisted solutions, however this article describes a simple, inexpensive, and repeatable method of obtaining a definitive wax cast of toe prosthesis.
- 1 October 2008
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (7) , 596-598
Fabricating a Hollow Obturator with Visible Light‐Cured Resin System
Obturators are routinely used in the rehabilitation of maxillectomy defects. Ideally, obturators should be easily constructed to produce a comfortable and stable prosthesis. This article describes a technique that provides an easy method for the construction of an obturator prosthesis using a visible light‐cured (VLC) resin. As a result, technicians can easily construct obturators in little time; this would, in turn, provide patients with light, comfortable, and tolerable prostheses.
- 1 October 2008
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (7) , 596-598
Fabricating a Hollow Obturator with Visible Light‐Cured Resin System
Obturators are routinely used in the rehabilitation of maxillectomy defects. Ideally, obturators should be easily constructed to produce a comfortable and stable prosthesis. This article describes a technique that provides an easy method for the construction of an obturator prosthesis using a visible light‐cured (VLC) resin. As a result, technicians can easily construct obturators in little time; this would, in turn, provide patients with light, comfortable, and tolerable prostheses.