Sima Singh
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sima Singh has a total of 157 co-authors. Here are the top co-authors by number of shared publications:
- Stefano Cinti
Chulalongkorn University
15 shared publications - Thomas Jay Webster
Division of Pre-College and Undergraduate Studies, Brown University, Providence, RI, USA
8 shared publications Ada Raucci
7 shared publications- Arshid Numan
Sunway Centre for Electrochemical Energy and Sustainable Technology (SCEEST), Faculty of Engineering and Technology, Sunway University, Bandar Sunway, Malaysia
7 shared publications - Afzal Hussain
Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia
6 shared publications - Prashant Kesharwani
Dr. Harisingh Gour Vishwavidyalaya (A Central University)
6 shared publications
Latest Publications
- Open Access
Transformative approaches for siRNA detection
Open AccessTransformative approaches for siRNA detection
- Open Access
- 14 July 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 418, 136219
Bismuth-MXene nanocomposite: A low-cost portable solution for zinc (II) detection in water for safer environmental monitoring
- 14 July 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 418, 136219
Open AccessBismuth-MXene nanocomposite: A low-cost portable solution for zinc (II) detection in water for safer environmental monitoring
- RetractionOpen Access
- 27 May 2024
- Published by MDPI AG in Pharmaceutics
- Vol. 16 (6) , 721
RETRACTED: Aldawsari et al. Gum Acacia Functionalized Colloidal Gold Nanoparticles of Letrozole as Biocompatible Drug Delivery Carrier for Treatment of Breast Cancer. Pharmaceutics 2021, 13, 1554
The Pharmaceutics Editorial Office retracts the article, “Gum Acacia Functionalized Colloidal Gold Nanoparticles of Letrozole as Biocompatible Drug Delivery Carrier for Treatment of Breast Cancer”
- 27 May 2024
- Published by MDPI AG in Pharmaceutics
- Vol. 16 (6) , 721
RetractionOpen AccessRETRACTED: Aldawsari et al. Gum Acacia Functionalized Colloidal Gold Nanoparticles of Letrozole as Biocompatible Drug Delivery Carrier for Treatment of Breast Cancer. Pharmaceutics 2021, 13, 1554
The Pharmaceutics Editorial Office retracts the article, “Gum Acacia Functionalized Colloidal Gold Nanoparticles of Letrozole as Biocompatible Drug Delivery Carrier for Treatment of Breast Cancer”
- Open Access
- 21 March 2024
- Published by Springer Nature in Communications Chemistry
- Vol. 7 (1) , 1-9
Paper-based electrochemical device for early detection of integrin αvβ6 expressing tumors
Despite progress in the prevention and diagnosis of cancer, current technologies for tumor detection present several limitations including invasiveness, toxicity, inaccuracy, lengthy testing duration and high cost. Therefore, innovative diagnostic techniques that integrate knowledge from biology, oncology, medicinal and analytical chemistry are now quickly emerging in the attempt to address these issues. Following this approach, here we developed a paper-based electrochemical device for detecting cancer-derived Small Extracellular Vesicles (S-EVs) in fluids. S-EVs were obtained from cancer cell lines known to express, at a different level, the αvβ6 integrin receptor, a well-established hallmark of numerous epithelial cancer types. The resulting biosensor turned out to recognize αvβ6-containing S-EVs down to a limit of 0.7*103 S-EVs/mL with a linear range up to 105 S-EVs /mL, and a relative standard deviation of 11%, thus it may represent a novel opportunity for αvβ6 expressing cancers detection.
- 21 March 2024
- Published by Springer Nature in Communications Chemistry
- Vol. 7 (1) , 1-9
Open AccessPaper-based electrochemical device for early detection of integrin αvβ6 expressing tumors
Despite progress in the prevention and diagnosis of cancer, current technologies for tumor detection present several limitations including invasiveness, toxicity, inaccuracy, lengthy testing duration and high cost. Therefore, innovative diagnostic techniques that integrate knowledge from biology, oncology, medicinal and analytical chemistry are now quickly emerging in the attempt to address these issues. Following this approach, here we developed a paper-based electrochemical device for detecting cancer-derived Small Extracellular Vesicles (S-EVs) in fluids. S-EVs were obtained from cancer cell lines known to express, at a different level, the αvβ6 integrin receptor, a well-established hallmark of numerous epithelial cancer types. The resulting biosensor turned out to recognize αvβ6-containing S-EVs down to a limit of 0.7*103 S-EVs/mL with a linear range up to 105 S-EVs /mL, and a relative standard deviation of 11%, thus it may represent a novel opportunity for αvβ6 expressing cancers detection.
- 20 February 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (9) , 3698-3706
Paper-Based Analytical Devices for Cancer Liquid Biopsy
Liquid biopsies have caused a significant revolution in cancer diagnosis, and the use of point of care (PoC) platforms has the potential to bring liquid biopsy-based cancer detection closer to patients. These platforms provide rapid and on-site analysis by reducing the time between sample collection and results output. The aim of this tutorial content is to provide readers an in-depth understanding regarding the choice of the ideal sensing platform suitable for specific cancer-related biomarkers.
- 20 February 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (9) , 3698-3706
Paper-Based Analytical Devices for Cancer Liquid Biopsy
Liquid biopsies have caused a significant revolution in cancer diagnosis, and the use of point of care (PoC) platforms has the potential to bring liquid biopsy-based cancer detection closer to patients. These platforms provide rapid and on-site analysis by reducing the time between sample collection and results output. The aim of this tutorial content is to provide readers an in-depth understanding regarding the choice of the ideal sensing platform suitable for specific cancer-related biomarkers.
- Open Access
- 9 February 2024
- Published by Wiley in ChemistryOpen
- Vol. 13 (7) , e202300203
Electrochemical detection of miRNA using commercial and hand‐made screen‐printed electrodes: liquid biopsy for cancer management as case of study
The growth of liquid biopsy, i. e., the possibility of obtaining health information by analysing circulating species (nucleic acids, cells, proteins, and vesicles) in peripheric biofluids, is pushing the field of sensors and biosensors beyond the limit to provide decentralised solutions for nonspecialists. In particular, among all the circulating species that can be adopted in managing cancer evolution, both for diagnostic and prognostic applications, microRNAs have been highly studied and detected. The development of electrochemical devices is particularly relevant for liquid biopsy purposes, and the screen‐printed electrodes (SPEs) represent one of the building blocks for producing novel portable devices. In this work, we have taken miR‐2115‐3p as model target (it is related to lung cancer), and we have developed a biosensor by exploiting the use of a complementary DNA probe modified with methylene blue as redox mediator. In particular, the chosen sensing architecture was applied to serum measurements of the selected miRNA, obtaining a detection limit within the low nanomolar range; in addition, various platforms were interrogated, namely commercial and hand‐made SPEs, with the aim of providing the reader with some insights about the optimal platform to be used by considering both the cost and the analytical performance.
- 9 February 2024
- Published by Wiley in ChemistryOpen
- Vol. 13 (7) , e202300203
Open AccessElectrochemical detection of miRNA using commercial and hand‐made screen‐printed electrodes: liquid biopsy for cancer management as case of study
The growth of liquid biopsy, i. e., the possibility of obtaining health information by analysing circulating species (nucleic acids, cells, proteins, and vesicles) in peripheric biofluids, is pushing the field of sensors and biosensors beyond the limit to provide decentralised solutions for nonspecialists. In particular, among all the circulating species that can be adopted in managing cancer evolution, both for diagnostic and prognostic applications, microRNAs have been highly studied and detected. The development of electrochemical devices is particularly relevant for liquid biopsy purposes, and the screen‐printed electrodes (SPEs) represent one of the building blocks for producing novel portable devices. In this work, we have taken miR‐2115‐3p as model target (it is related to lung cancer), and we have developed a biosensor by exploiting the use of a complementary DNA probe modified with methylene blue as redox mediator. In particular, the chosen sensing architecture was applied to serum measurements of the selected miRNA, obtaining a detection limit within the low nanomolar range; in addition, various platforms were interrogated, namely commercial and hand‐made SPEs, with the aim of providing the reader with some insights about the optimal platform to be used by considering both the cost and the analytical performance.
- Open Access
- 12 December 2023
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 4 (1) , 136-143
Technical Evaluation of a Paper-Based Electrochemical Strip to Measure Nitrite Ions in the Forensic Field
Nitrite is a compound used as a food additive for its preservative action and coloring capability, as well as an industrial agent for its antifreezing action and for preventing corrosion, and it is also used as a pharmaceutical in cyanide detoxification therapy. However, even recently, because of its high toxicity, it has been used as a murder and suicidal agent due to its affordability and ready availability. In this technical report, we describe an electrochemical paper-based device for selectively determining nitrite in complex biofluids, such as blood, cadaveric blood, vitreous humor, serum, plasma, and urine. The approach was validated in terms of the linearity of response, selectivity, and sensitivity, and the accuracy of the determination was verified by comparing the results with a chromatographic instrumental method. A linear response was observed in the micromolar range; the sensitivity of the method expressed as the limit of detection was 0.4 μM in buffer measurements. The simplicity of use, the portability of the device, and the performance shown make the approach suitable for detecting nitrite in complex biofluids, including contexts of forensic interest, such as murders or suicides in which nitrite is used as a toxic agent. Limits of detection of ca. 1, 2, 4, 5, 3, and 4 μM were obtained in vitreous humor, urine, serum and plasma, blood, and cadaveric blood, also highlighting a satisfactory accuracy comprised between 91 and 112%.
- 12 December 2023
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 4 (1) , 136-143
Open AccessTechnical Evaluation of a Paper-Based Electrochemical Strip to Measure Nitrite Ions in the Forensic Field
Nitrite is a compound used as a food additive for its preservative action and coloring capability, as well as an industrial agent for its antifreezing action and for preventing corrosion, and it is also used as a pharmaceutical in cyanide detoxification therapy. However, even recently, because of its high toxicity, it has been used as a murder and suicidal agent due to its affordability and ready availability. In this technical report, we describe an electrochemical paper-based device for selectively determining nitrite in complex biofluids, such as blood, cadaveric blood, vitreous humor, serum, plasma, and urine. The approach was validated in terms of the linearity of response, selectivity, and sensitivity, and the accuracy of the determination was verified by comparing the results with a chromatographic instrumental method. A linear response was observed in the micromolar range; the sensitivity of the method expressed as the limit of detection was 0.4 μM in buffer measurements. The simplicity of use, the portability of the device, and the performance shown make the approach suitable for detecting nitrite in complex biofluids, including contexts of forensic interest, such as murders or suicides in which nitrite is used as a toxic agent. Limits of detection of ca. 1, 2, 4, 5, 3, and 4 μM were obtained in vitreous humor, urine, serum and plasma, blood, and cadaveric blood, also highlighting a satisfactory accuracy comprised between 91 and 112%.
- Open Access
- 17 August 2023
- Published by Frontiers Media SA in Frontiers in Microbiology
- Vol. 14, 1215529
Reviewing the state of biosensors and lab-on-a- chip technologies: opportunities for extreme environments and space exploration
The space race is entering a new era of exploration, in which the number of robotic and human missions to various places in our solar system is rapidly increasing. Despite the recent advances in propulsion and life support technologies, there is a growing need to perform analytical measurements and laboratory experiments across diverse domains of science, while keeping low payload requirements. In this context, lab-on-a-chip nanobiosensors appear to be an emerging technology capable of revolutionizing space exploration, given their low footprint, high accuracy, and low payload requirements. To date, only some approaches for monitoring astronaut health in spacecraft environments have been reported. Although non-invasive molecular diagnostics, like lab-on-a-chip technology, are expected to improve the quality of long-term space missions, their application to monitor microbiological and environmental variables is rarely reported, even for analogous extreme environments on Earth. The possibility of evaluating the occurrence of unknown or unexpected species, identifying redox gradients relevant to microbial metabolism, or testing for specific possible biosignatures, will play a key role in the future of space microbiology. In this review, we will examine the current and potential roles of lab-on-a-chip technology in space exploration and in extreme environment investigation, reporting what has been tested so far, and clarifying the direction toward which the newly developed technologies of portable lab-on-a-chip sensors are heading for exploration in extreme environments and in space.
- 17 August 2023
- Published by Frontiers Media SA in Frontiers in Microbiology
- Vol. 14, 1215529
Open AccessReviewing the state of biosensors and lab-on-a- chip technologies: opportunities for extreme environments and space exploration
The space race is entering a new era of exploration, in which the number of robotic and human missions to various places in our solar system is rapidly increasing. Despite the recent advances in propulsion and life support technologies, there is a growing need to perform analytical measurements and laboratory experiments across diverse domains of science, while keeping low payload requirements. In this context, lab-on-a-chip nanobiosensors appear to be an emerging technology capable of revolutionizing space exploration, given their low footprint, high accuracy, and low payload requirements. To date, only some approaches for monitoring astronaut health in spacecraft environments have been reported. Although non-invasive molecular diagnostics, like lab-on-a-chip technology, are expected to improve the quality of long-term space missions, their application to monitor microbiological and environmental variables is rarely reported, even for analogous extreme environments on Earth. The possibility of evaluating the occurrence of unknown or unexpected species, identifying redox gradients relevant to microbial metabolism, or testing for specific possible biosignatures, will play a key role in the future of space microbiology. In this review, we will examine the current and potential roles of lab-on-a-chip technology in space exploration and in extreme environment investigation, reporting what has been tested so far, and clarifying the direction toward which the newly developed technologies of portable lab-on-a-chip sensors are heading for exploration in extreme environments and in space.
- 12 July 2023
- Published by Royal Society of Chemistry (RSC)
- p. 55-72
Anodic and cathodic stripping voltammetry for metals sensing
This chapter introduces the fundamental ideas of voltammetry, such as adjusting the voltage and measuring the current that results from electrochemical reactions. The procedure known as stripping analysis can be divided into two stages: electrolytic deposition of a part of the metal ions in solution at the working electrode is frequently employed to pre-concentrate the metals during the first step of the process, which is referred to as the deposition stage. After the pre-concentration comes to the stripping stage, also known as the measuring step. During this process, the precipitate is dissolved. The main focus of this chapter is on anodic and cathodic stripping voltammetry, both of which are used to detect metals. This chapter discusses the theory that underpins the techniques as well as the potential applications of stripping analysis for the detection of analytes in a variety of real-sample such as water, soil extracts, and biological fluids (blood and saliva) with a high degree of specificity, sensitivity (detection limits of ppb), and reliability. The chapter also covers the theory that underpins the techniques and the potential applications of stripping analysis. The analysis of water for the presence of analytes is the primary topic of this chapter. Electroanalytical methods are given a concise explanation in this chapter, along with their mode of operation and the various phenomena that can be investigated with the help of these methods. In addition, a few other applications of electrochemical sensors and a general review of these sensors are discussed.
- 12 July 2023
- Published by Royal Society of Chemistry (RSC)
- p. 55-72
Anodic and cathodic stripping voltammetry for metals sensing
This chapter introduces the fundamental ideas of voltammetry, such as adjusting the voltage and measuring the current that results from electrochemical reactions. The procedure known as stripping analysis can be divided into two stages: electrolytic deposition of a part of the metal ions in solution at the working electrode is frequently employed to pre-concentrate the metals during the first step of the process, which is referred to as the deposition stage. After the pre-concentration comes to the stripping stage, also known as the measuring step. During this process, the precipitate is dissolved. The main focus of this chapter is on anodic and cathodic stripping voltammetry, both of which are used to detect metals. This chapter discusses the theory that underpins the techniques as well as the potential applications of stripping analysis for the detection of analytes in a variety of real-sample such as water, soil extracts, and biological fluids (blood and saliva) with a high degree of specificity, sensitivity (detection limits of ppb), and reliability. The chapter also covers the theory that underpins the techniques and the potential applications of stripping analysis. The analysis of water for the presence of analytes is the primary topic of this chapter. Electroanalytical methods are given a concise explanation in this chapter, along with their mode of operation and the various phenomena that can be investigated with the help of these methods. In addition, a few other applications of electrochemical sensors and a general review of these sensors are discussed.