FEFrank Edzards

Frank Edzards

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Frank Edzards has a total of 149 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Surface Characterization of P-Type Point Contact Germanium Detectors

    by Frank Edzards, Lukas Hauertmann, Iris Abt, Chris Gooch, Björn Lehnert, Xiang Liu, Susanne Mertens, David C. Radford, Oliver Schulz, Michael Willers

    P-type point contact (PPC) germanium detectors are used in rare event and low-background searches, including neutrinoless double beta (0νββ) decay, low-energy nuclear recoils, and coherent elastic neutrino-nucleus scattering. The detectors feature an excellent energy resolution, low detection thresholds down to the sub-keV range, and enhanced background rejection capabilities. However, due to their large passivated surface, separating the signal readout contact from the bias voltage electrode, PPC detectors are susceptible to surface effects such as charge build-up. A profound understanding of their response to surface events is essential. In this work, the response of a PPC detector to alpha and beta particles hitting the passivated surface was investigated in a multi-purpose scanning test stand. It is shown that the passivated surface can accumulate charges resulting in a radial-dependent degradation of the observed event energy. In addition, it is demonstrated that the pulse shapes of surface alpha events show characteristic features which can be used to discriminate against these events.


  • Open Access

    Investigation of ASIC-based signal readout electronics for LEGEND-1000

    by F. Edzards, M. Willers, A. Alborini, L. Bombelli, D. Fink, M. P. Green, M. Laubenstein, S. Mertens, G. Othman, D. C. Radford, et al.


  • Open Access

    Quantitative Long-Term Monitoring of the Circulating Gases in the KATRIN Experiment Using Raman Spectroscopy

    by Max Aker, Konrad Altenmüller, Armen Beglarian, Jan Behrens, Anatoly Berlev, Uwe Besserer, Benedikt Bieringer, Klaus Blaum, Fabian Block, Beate Bornschein, et al.

    The Karlsruhe Tritium Neutrino (KATRIN) experiment aims at measuring the effective electron neutrino mass with a sensitivity of 0.2 eV/c2, i.e., improving on previous measurements by an order of magnitude. Neutrino mass data taking with KATRIN commenced in early 2019, and after only a few weeks of data recording, analysis of these data showed the success of KATRIN, improving on the known neutrino mass limit by a factor of about two. This success very much could be ascribed to the fact that most of the system components met, or even surpassed, the required specifications during long-term operation. Here, we report on the performance of the laser Raman (LARA) monitoring system which provides continuous high-precision information on the gas composition injected into the experiment’s windowless gaseous tritium source (WGTS), specifically on its isotopic purity of tritium—one of the key parameters required in the derivation of the electron neutrino mass. The concentrations cx for all six hydrogen isotopologues were monitored simultaneously, with a measurement precision for individual components of the order 10−3 or better throughout the complete KATRIN data taking campaigns to date. From these, the tritium purity, εT, is derived with precision of −3 and trueness of −3, being within and surpassing the actual requirements for KATRIN, respectively.


  • Open Access

    Investigation of ASIC-based signal readout electronics for LEGEND-1000

    by F. Edzards, M. Willers, A. Alborini, L. Bombelli, D. Fink, M. P. Green, M. Laubenstein, S. Mertens, G. Othman, D. C. Radford, et al.

    LEGEND, the Large Enriched Germanium Experiment for Neutrinoless $\beta\beta$ Decay, is a ton-scale experimental program to search for neutrinoless double beta ($0\nu\beta\beta$) decay in the isotope $^{76}$Ge with an unprecedented sensitivity. Building on the success of the low-background $^{76}$Ge-based GERDA and MAJORANA DEMONSTRATOR experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond $10^{28}\,$yr on the decay half-life with approximately $10\,\text{t}\cdot\text{yr}$ of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

  • Open Access

    Development of signal readout electronics for LEGEND-1000

    by Frank Edzards, Susanne Mertens, Michael Willers

    The Large Enriched Germanium Experiment for Neutrinoless ββ Decay (LEGEND) is a future ton-scale experimental program that will search for neutrinoless double beta decay (0vββ) in the isotope 76Ge with an unprecedented sensitivity. To achieve the projected discovery sensitivity at a half-life beyond 1028 yr after about ten years of data taking, it is of utmost importance to operate in a background-free environment. This can be supported by using highly integrated readout electronics such as application-specific integrated circuit (ASIC) technology. In this work we investigated the properties and electronic performance of a commercially available ASIC charge sensitive preamplifier, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector.

  • Open Access

    Development of signal readout electronics for LEGEND-1000

    by Frank Edzards, Susanne Mertens, Michael Willers

    The Large Enriched Germanium Experiment for Neutrinoless $\beta\beta$ Decay (LEGEND) is a future ton-scale experimental program that will search for neutrinoless double beta decay ($0\nu\beta\beta$) in the isotope $^{76}$Ge with an unprecedented sensitivity. To achieve the projected discovery sensitivity at a half-life beyond $10^{28}\,$yr after about ten years of data taking, it is of utmost importance to operate in a background-free environment. This can be supported by using highly integrated readout electronics such as application-specific integrated circuit (ASIC) technology. In this work we investigated the properties and electronic performance of a commercially available ASIC charge sensitive preamplifier, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector.