Régis Vaudemont
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Régis Vaudemont has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Henri Perrin
Luxembourg Institute of Science and Technology (LIST), 5, rue Bommel, L-4940 Hautcharage, Luxembourg
3 shared publications - Masoud Bodaghi
Luxembourg Institute of Science and Technology (LIST), 5, rue Bommel, L-4940 Hautcharage, Luxembourg
3 shared publications - Vincent Berthé
Responsive Polymeric and Particulate Materials, Functional Polymers and Particulate Materials Unit, Luxembourg Institute of Science and Technology (LIST), L-4362 Esch-sur-Alzette, Luxembourg
2 shared publications - Adham Al-Sayyad
Université du Luxembourg
1 shared publication - Alexander S. Shaplov
Luxembourg Institute of Science and Technology (LIST), Functional Polymeric and Particulate Materials Unit, 5 Avenue des Hauts-Fourneaux, L-4362 Esch-sur-Alzette, Luxembourg
1 shared publication - Elena I. Lozinskaya
A.N. Nesmeyanov Institute of Organoelement Compounds Russian Academy of Sciences (INEOS RAS), Moscow, Russia
1 shared publication
Latest Publications
- Open Access
On the Analyses of Cure Cycle Effects on Peel Strength Characteristics in Carbon High-Tg Epoxy/Plasma-Activated Carbon PEEK Composite Interfaces: A Preliminary Inquiry
In this study, a high-Tg aerospace-grade epoxy composite plate was co-curing welded using a unidirectional PEEK thermoplastic carbon fibre tape to develop advanced composite joints. To account for the surface roughness and the weldability of carbon–epoxy/carbon–PEEK composites, plasma treatments were performed. The co-curing was conducted by the following steps: each treated thermoplastic tape was first placed in the mould, and followed by nine layers of dry-woven carbon fabrics. The mould was sealed using a vacuum bag, and a bi-component thermoset (RTM6) impregnated the preform. To understand the role of curing kinetics, post-curing, curing temperature, and dwell time on the quality of joints, five cure cycles were programmed. The strengths of the welded joints were investigated via the interlayer peeling test. Furthermore, cross-sections of welded zones were assessed using scanning electron microscopy in terms of the morphology of the PEEK/epoxy interphase after co-curing. The preliminary results showed that the cure cycle is an important controlling parameter for crack propagation. A noticeable distinction was evident between the samples cured first at 140 °C for 2 h and then at 180 °C for 2 h, and those cured initially at 150 °C for 2 h followed by 180 °C for 2 h. In other words, the samples subjected to the latter curing conditions exhibited consistently reproducible results with minimal errors compared to different samples. The reduced errors confirmed the reproducibility of these samples, indicating that the adhesion between CF/PEEK and CF/RTM6 tends to be more stable in this curing scenario.
Open AccessOn the Analyses of Cure Cycle Effects on Peel Strength Characteristics in Carbon High-Tg Epoxy/Plasma-Activated Carbon PEEK Composite Interfaces: A Preliminary Inquiry
In this study, a high-Tg aerospace-grade epoxy composite plate was co-curing welded using a unidirectional PEEK thermoplastic carbon fibre tape to develop advanced composite joints. To account for the surface roughness and the weldability of carbon–epoxy/carbon–PEEK composites, plasma treatments were performed. The co-curing was conducted by the following steps: each treated thermoplastic tape was first placed in the mould, and followed by nine layers of dry-woven carbon fabrics. The mould was sealed using a vacuum bag, and a bi-component thermoset (RTM6) impregnated the preform. To understand the role of curing kinetics, post-curing, curing temperature, and dwell time on the quality of joints, five cure cycles were programmed. The strengths of the welded joints were investigated via the interlayer peeling test. Furthermore, cross-sections of welded zones were assessed using scanning electron microscopy in terms of the morphology of the PEEK/epoxy interphase after co-curing. The preliminary results showed that the cure cycle is an important controlling parameter for crack propagation. A noticeable distinction was evident between the samples cured first at 140 °C for 2 h and then at 180 °C for 2 h, and those cured initially at 150 °C for 2 h followed by 180 °C for 2 h. In other words, the samples subjected to the latter curing conditions exhibited consistently reproducible results with minimal errors compared to different samples. The reduced errors confirmed the reproducibility of these samples, indicating that the adhesion between CF/PEEK and CF/RTM6 tends to be more stable in this curing scenario.
- Open Access
On the Addition of Multifunctional Methacrylate Monomers to an Acrylic-Based Infusible Resin for the Weldability of Acrylic-Based Glass Fibre Composites
The melt strength of Elium® acrylic resin is an important factor to ensure limited fluid flow during welding. To provide Elium® with a suitable melt strength via a slight crosslink, this study examines the effect of two dimethacrylates, namely butanediol-di-methacrylate (BDDMA) and tricyclo-decane-dimethanol-di-methacrylate (TCDDMDA), on the weldability of acrylic-based glass fibre composites. The resin system impregnating a five-layer woven glass preform is a mixture of Elium® acrylic resin, an initiator, and each of the multifunctional methacrylate monomers in the range of 0 to 2 parts per hundred resin (phr). Composite plates are manufactured by vacuum infusion (VI) at an ambient temperature and welded by using the infrared (IR) welding technique. The mechanical thermal analysis of the composites containing multifunctional methacrylate monomers higher than 0.25 phr shows a very little strain for the temperature range of 50 °C to 220 °C. The quantity of 0.25 phr of both of the multifunctional methacrylate monomers in the Elium® matrix improves the maximum bound shear strength of the weld by 50% compared to those compositions without the multifunctional methacrylate monomers.
Open AccessOn the Addition of Multifunctional Methacrylate Monomers to an Acrylic-Based Infusible Resin for the Weldability of Acrylic-Based Glass Fibre Composites
The melt strength of Elium® acrylic resin is an important factor to ensure limited fluid flow during welding. To provide Elium® with a suitable melt strength via a slight crosslink, this study examines the effect of two dimethacrylates, namely butanediol-di-methacrylate (BDDMA) and tricyclo-decane-dimethanol-di-methacrylate (TCDDMDA), on the weldability of acrylic-based glass fibre composites. The resin system impregnating a five-layer woven glass preform is a mixture of Elium® acrylic resin, an initiator, and each of the multifunctional methacrylate monomers in the range of 0 to 2 parts per hundred resin (phr). Composite plates are manufactured by vacuum infusion (VI) at an ambient temperature and welded by using the infrared (IR) welding technique. The mechanical thermal analysis of the composites containing multifunctional methacrylate monomers higher than 0.25 phr shows a very little strain for the temperature range of 50 °C to 220 °C. The quantity of 0.25 phr of both of the multifunctional methacrylate monomers in the Elium® matrix improves the maximum bound shear strength of the weld by 50% compared to those compositions without the multifunctional methacrylate monomers.
- Open Access
On the Hot-Plate Welding of Reactively Compatibilized Acrylic-Based Composites/Polyamide (PA)-12
Joining of dissimilar thermoplastics and their composites is a challenge for thermal welding techniques due to different melting points. Reactive welding with an auxiliary functional material can offer the clear opportunities to develop joining processes due to robustness to joining dissimilar thermoplastic polymers and their composites. The current study employed reactive compatibilization to offer the possibility of joining an acrylic-based glass fiber composite to polyamide (PA)-12 by applying a hot-tool welding technique. For this purpose, composite plates are fabricated by a typical vacuum infusion and thin layer thermoplastic films are formed by a thermostamping of PA12 granules. Subsequently, the reactive welding of the interposed PA12 sheet and Elium®-GMA-Glass composite is conducted by hot-plate welding. A glycidyl methacrylate (GMA) as a compatibilizing agent is copolymerized with methyl methacrylate Elium® resin. During the hot-tool welding process of dissimilar thermoplastic material, GMA can react with the polyamide end groups. The heat distribution at the Elium® GMA/PA-12 interface is responsible for obtaining a strong joint. This study focuses on the functionality of the compatibilizer on the welding of acrylic-based composites with polyamide (PA)-12 while varying the assembly temperature. The flatwise tensile test proved the effectiveness of GMA on the interface bounding. The excellent bounding incompatible polymers Elium® resin (PMMA) and PA12 was achieved at 200 °C.
Open AccessOn the Hot-Plate Welding of Reactively Compatibilized Acrylic-Based Composites/Polyamide (PA)-12
Joining of dissimilar thermoplastics and their composites is a challenge for thermal welding techniques due to different melting points. Reactive welding with an auxiliary functional material can offer the clear opportunities to develop joining processes due to robustness to joining dissimilar thermoplastic polymers and their composites. The current study employed reactive compatibilization to offer the possibility of joining an acrylic-based glass fiber composite to polyamide (PA)-12 by applying a hot-tool welding technique. For this purpose, composite plates are fabricated by a typical vacuum infusion and thin layer thermoplastic films are formed by a thermostamping of PA12 granules. Subsequently, the reactive welding of the interposed PA12 sheet and Elium®-GMA-Glass composite is conducted by hot-plate welding. A glycidyl methacrylate (GMA) as a compatibilizing agent is copolymerized with methyl methacrylate Elium® resin. During the hot-tool welding process of dissimilar thermoplastic material, GMA can react with the polyamide end groups. The heat distribution at the Elium® GMA/PA-12 interface is responsible for obtaining a strong joint. This study focuses on the functionality of the compatibilizer on the welding of acrylic-based composites with polyamide (PA)-12 while varying the assembly temperature. The flatwise tensile test proved the effectiveness of GMA on the interface bounding. The excellent bounding incompatible polymers Elium® resin (PMMA) and PA12 was achieved at 200 °C.
- Open Access
Ionic Polyureas—A Novel Subclass of Poly(Ionic Liquid)s for CO2 Capture
The growing concern for climate change and global warming has given rise to investigations in various research fields, including one particular area dedicated to the creation of solid sorbents for efficient CO2 capture. In this work, a new family of poly(ionic liquid)s (PILs) comprising cationic polyureas (PURs) with tetrafluoroborate (BF4) anions has been synthesized. Condensation of various diisocyanates with novel ionic diamines and subsequent ion metathesis reaction resulted in high molar mass ionic PURs (Mw = 12 ÷ 173 × 103 g/mol) with high thermal stability (up to 260 °C), glass transition temperatures in the range of 153–286 °C and remarkable CO2 capture (10.5–24.8 mg/g at 0 °C and 1 bar). The CO2 sorption was found to be dependent on the nature of the cation and structure of the diisocyanate. The highest sorption was demonstrated by tetrafluoroborate PUR based on 4,4′-methylene-bis(cyclohexyl isocyanate) diisocyanate and aromatic diamine bearing quinuclidinium cation (24.8 mg/g at 0 °C and 1 bar). It is hoped that the present study will inspire novel design strategies for improving the sorption properties of PILs and the creation of novel effective CO2 sorbents.
Open AccessIonic Polyureas—A Novel Subclass of Poly(Ionic Liquid)s for CO2 Capture
The growing concern for climate change and global warming has given rise to investigations in various research fields, including one particular area dedicated to the creation of solid sorbents for efficient CO2 capture. In this work, a new family of poly(ionic liquid)s (PILs) comprising cationic polyureas (PURs) with tetrafluoroborate (BF4) anions has been synthesized. Condensation of various diisocyanates with novel ionic diamines and subsequent ion metathesis reaction resulted in high molar mass ionic PURs (Mw = 12 ÷ 173 × 103 g/mol) with high thermal stability (up to 260 °C), glass transition temperatures in the range of 153–286 °C and remarkable CO2 capture (10.5–24.8 mg/g at 0 °C and 1 bar). The CO2 sorption was found to be dependent on the nature of the cation and structure of the diisocyanate. The highest sorption was demonstrated by tetrafluoroborate PUR based on 4,4′-methylene-bis(cyclohexyl isocyanate) diisocyanate and aromatic diamine bearing quinuclidinium cation (24.8 mg/g at 0 °C and 1 bar). It is hoped that the present study will inspire novel design strategies for improving the sorption properties of PILs and the creation of novel effective CO2 sorbents.
- Open Access
Influence of Aluminum Laser Ablation on Interfacial Thermal Transfer and Joint Quality of Laser Welded Aluminum–Polyamide Assemblies
Laser assisted metal–polymer joining (LAMP) is a novel assembly process for the development of hybrid lightweight products with customized properties. It was already demonstrated that laser ablation of aluminum alloy Al1050 (Al) prior to joining with polyamide 6.6 (PA) has significant influence on the joint quality, manifested in the joint area. However, profound understanding of the factors affecting the joint quality was missing. This work investigates the effects of laser ablation on the surface properties of Al, discusses their corresponding impact on the interfacial thermal transfer between the joining partners, and evaluates their effects on the joint quality. Samples ablated with different parameters, resulting in a range from low- to high-quality joints, were selected, and their surface properties were analyzed by using 2D profilometry, X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), and energy-dispersive X-ray spectroscopy (EDX). In order to analyze the effects of laser ablation parameters on the interfacial thermal transfer between metal and polymer, a model two-layered system was analyzed, using laser flash analysis (LFA), and the thermal contact resistance (TCR) was quantified. Results indicate a strong influence of laser-ablation parameters on the surface structural and morphological properties, influencing the thermal transfer during the laser welding process, thus affecting the joint quality and its resistance to shear load.
Open AccessInfluence of Aluminum Laser Ablation on Interfacial Thermal Transfer and Joint Quality of Laser Welded Aluminum–Polyamide Assemblies
Laser assisted metal–polymer joining (LAMP) is a novel assembly process for the development of hybrid lightweight products with customized properties. It was already demonstrated that laser ablation of aluminum alloy Al1050 (Al) prior to joining with polyamide 6.6 (PA) has significant influence on the joint quality, manifested in the joint area. However, profound understanding of the factors affecting the joint quality was missing. This work investigates the effects of laser ablation on the surface properties of Al, discusses their corresponding impact on the interfacial thermal transfer between the joining partners, and evaluates their effects on the joint quality. Samples ablated with different parameters, resulting in a range from low- to high-quality joints, were selected, and their surface properties were analyzed by using 2D profilometry, X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), and energy-dispersive X-ray spectroscopy (EDX). In order to analyze the effects of laser ablation parameters on the interfacial thermal transfer between metal and polymer, a model two-layered system was analyzed, using laser flash analysis (LFA), and the thermal contact resistance (TCR) was quantified. Results indicate a strong influence of laser-ablation parameters on the surface structural and morphological properties, influencing the thermal transfer during the laser welding process, thus affecting the joint quality and its resistance to shear load.