Takeshi Takamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takeshi Takamura has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Tetsuya Seko
Department of Cardiology, Ise Red Cross Hospital, Ise, Mie, Japan
5 shared publicationsAtsunobu Kasai
Department of Cardiology, Ise Red Cross Hospital
4 shared publicationsHokuto Yamagishi
Department of Cardiology, Ise Red Cross Hospital, Ise, Mie, Japan
4 shared publicationsKaoru Dohi
Department of Cardiology and Nephrology, Mie University Graduate School of Medicine, Tsu, Japan
3 shared publicationsShintaro Sakaguchi
Department of Cardiology, Ise Red Cross Hospital, Ise, Mie, Japan
3 shared publicationsMasaaki Ito
Department of Cardiology and Nephrology, Mie University Graduate School of Medicine, Tsu, Mie, Japan
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Japan Transcatheter Valve Therapies in Journal of Transcatheter Valve Therapies
- Vol. 8 (1) , 167-172
Successful Post-Dilatation Bailout for Nose Cone Entrapment During Self-Expanding Transcatheter Aortic Valve Replacement
Objective: Transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) with extensive annular calcification remains challenging. Although self-expanding transcatheter heart valves (THVs) may reduce the risk of annular rupture, nose cone entrapment is a rare but potentially serious complication. We report a case of nose cone entrapment during TAVR with a self-expanding THV that was successfully managed by additional post-dilatation.Case Presentation: An 85-year-old woman underwent percutaneous coronary intervention for an anteroseptal acute myocardial infarction complicated by cardiogenic shock 14 days before being transferred to our hospital. Despite intensive treatment with dobutamine and an intra-aortic balloon pump, she was referred to our hospital for refractory heart failure associated with severe AS. A self-expanding THV was selected because of extensive aortic valve and annular calcification. After pre-dilatation with a 20-mm Inoue balloon catheter (Toray Industries, Tokyo, Japan), a 26-mm Evolut FX+ self-expanding THV (Medtronic, Minneapolis, MN, USA) was deployed 5–6 mm below the virtual aortic annulus. During withdrawal of the delivery system, the nose cone became entrapped at the THV inflow because of asymmetric stent-frame underexpansion. Additional post-dilatation with an 18-mm balloon improved stent-frame expansion and enabled successful retrieval of the entrapped nose cone. Her subsequent clinical course was uneventful, and she was discharged 13 days after TAVR.Conclusion: Nose cone entrapment during self-expanding TAVR can be successfully managed by additional post-dilatation when asymmetric stent-frame underexpansion is the underlying mechanism.
- 1 January 2026
- Published by Japan Transcatheter Valve Therapies in Journal of Transcatheter Valve Therapies
- Vol. 8 (1) , 167-172
Open AccessSuccessful Post-Dilatation Bailout for Nose Cone Entrapment During Self-Expanding Transcatheter Aortic Valve Replacement
Objective: Transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) with extensive annular calcification remains challenging. Although self-expanding transcatheter heart valves (THVs) may reduce the risk of annular rupture, nose cone entrapment is a rare but potentially serious complication. We report a case of nose cone entrapment during TAVR with a self-expanding THV that was successfully managed by additional post-dilatation.Case Presentation: An 85-year-old woman underwent percutaneous coronary intervention for an anteroseptal acute myocardial infarction complicated by cardiogenic shock 14 days before being transferred to our hospital. Despite intensive treatment with dobutamine and an intra-aortic balloon pump, she was referred to our hospital for refractory heart failure associated with severe AS. A self-expanding THV was selected because of extensive aortic valve and annular calcification. After pre-dilatation with a 20-mm Inoue balloon catheter (Toray Industries, Tokyo, Japan), a 26-mm Evolut FX+ self-expanding THV (Medtronic, Minneapolis, MN, USA) was deployed 5–6 mm below the virtual aortic annulus. During withdrawal of the delivery system, the nose cone became entrapped at the THV inflow because of asymmetric stent-frame underexpansion. Additional post-dilatation with an 18-mm balloon improved stent-frame expansion and enabled successful retrieval of the entrapped nose cone. Her subsequent clinical course was uneventful, and she was discharged 13 days after TAVR.Conclusion: Nose cone entrapment during self-expanding TAVR can be successfully managed by additional post-dilatation when asymmetric stent-frame underexpansion is the underlying mechanism.
- 24 September 2025
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 41 (1) , 183-184
Successful balloon angioplasty for superior vena cava syndrome caused by CRT-D pacemaker leads
- 24 September 2025
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 41 (1) , 183-184
Successful balloon angioplasty for superior vena cava syndrome caused by CRT-D pacemaker leads
- Open Access
- 25 April 2024
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 88 (5) , 761
First Case of COVID-19-Related Left Ventricular Calcification
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 25 April 2024
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 88 (5) , 761
Open AccessFirst Case of COVID-19-Related Left Ventricular Calcification
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 15 August 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (16) , e029717
Cardiac Reversibility and Survival After Transcatheter Aortic Valve Implantation in Patients With Low‐Gradient Aortic Stenosis
Background: Prognostic implications of transcatheter aortic valve implantation (TAVI) in low‐gradient (LG) aortic stenosis (AS) remain controversial. The authors hypothesized that differences in cardiac functional recovery may solve this ongoing controversy. The aim was to evaluate clinical outcomes and the response of left ventricular (LV) function following TAVI in patients with LG AS. Methods and Results: This multicenter retrospective study included 1742 patients with severe AS undergoing TAVI between January 2015 and March 2019. Patients were subdivided into low‐flow (LF) LG, normal‐flow (NF) LG, LF high‐gradient, and NF high‐gradient AS groups according to the mean gradient of the aortic valve (LG 2 ). Outcomes and changes in echocardiographic parameters after TAVI were compared between the groups. A total of 227 patients (13%) had reduced ejection fraction, and 486 patients (28%) had LG AS (LF‐LG 143 [8%]; NF‐LG 343 [20%]). During a median follow‐up period of 747 days, 301 patients experienced a composite end point of cardiovascular death and rehospitalization for cardiovascular events, which was higher in the LF‐LG and NF‐LG groups than in the high‐gradient groups. LG AS was independently associated with the primary outcome (hazard ratio, 1.69; P <0.001). Among 1239 patients with follow‐up echocardiography, LG AS showed less improvement in the LV mass index and LV end‐diastolic volume compared with high‐gradient AS after 1 year, while LV recovery was similar between the LF AS and NF AS groups. Conclusions: LG AS was associated with poorer outcomes and LV recovery, regardless of flow status after TAVI. Careful evaluation of AS severity may be required in LG AS to provide TAVI within the appropriate time and advanced care afterward.
- 15 August 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (16) , e029717
Open AccessCardiac Reversibility and Survival After Transcatheter Aortic Valve Implantation in Patients With Low‐Gradient Aortic Stenosis
Background: Prognostic implications of transcatheter aortic valve implantation (TAVI) in low‐gradient (LG) aortic stenosis (AS) remain controversial. The authors hypothesized that differences in cardiac functional recovery may solve this ongoing controversy. The aim was to evaluate clinical outcomes and the response of left ventricular (LV) function following TAVI in patients with LG AS. Methods and Results: This multicenter retrospective study included 1742 patients with severe AS undergoing TAVI between January 2015 and March 2019. Patients were subdivided into low‐flow (LF) LG, normal‐flow (NF) LG, LF high‐gradient, and NF high‐gradient AS groups according to the mean gradient of the aortic valve (LG 2 ). Outcomes and changes in echocardiographic parameters after TAVI were compared between the groups. A total of 227 patients (13%) had reduced ejection fraction, and 486 patients (28%) had LG AS (LF‐LG 143 [8%]; NF‐LG 343 [20%]). During a median follow‐up period of 747 days, 301 patients experienced a composite end point of cardiovascular death and rehospitalization for cardiovascular events, which was higher in the LF‐LG and NF‐LG groups than in the high‐gradient groups. LG AS was independently associated with the primary outcome (hazard ratio, 1.69; P <0.001). Among 1239 patients with follow‐up echocardiography, LG AS showed less improvement in the LV mass index and LV end‐diastolic volume compared with high‐gradient AS after 1 year, while LV recovery was similar between the LF AS and NF AS groups. Conclusions: LG AS was associated with poorer outcomes and LV recovery, regardless of flow status after TAVI. Careful evaluation of AS severity may be required in LG AS to provide TAVI within the appropriate time and advanced care afterward.
- 16 December 2019
- Published by Springer Nature in Journal of Echocardiography
- Vol. 19 (3) , 179-180
Patent foramen ovale and the platypnea-orthodeoxia syndrome detected by transesophageal echocardiography
- 16 December 2019
- Published by Springer Nature in Journal of Echocardiography
- Vol. 19 (3) , 179-180
Patent foramen ovale and the platypnea-orthodeoxia syndrome detected by transesophageal echocardiography
- 19 November 2019
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 35 (4) , 415-416
Successful bailout of Sapien 3 valve balloon rupture during transcatheter valve implantation via transaortic approach
- 19 November 2019
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 35 (4) , 415-416
Successful bailout of Sapien 3 valve balloon rupture during transcatheter valve implantation via transaortic approach