Shaofeng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shaofeng Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Hailing Wang
Inner Mongolia North Heavy Industries Group Company Limited, Changqian Rd., Baotou, Inner Mongolia Province 014033, China
2 shared publications - Jianguo Wang
School of Mechanical Engineering, Inner Mongolia University of Science and Technology, Baotou 014010, China
2 shared publications - Chunsheng Ji
Baotou Special Equipment Inspection Institution, No.4 Xingfu Rd., Baotou, Inner Mongolia Province 014030, China
1 shared publication - Daorui Wang
School of Mechanical Engineering, Inner Mongolia University of Science and Technology, Baotou, Inner Mongolia Province, China
1 shared publication - Jun Hong
Key Laboratory of Education Ministry for Modern Design and Rotor-Bearing System, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Jun Hong
State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, No.28 Xianning West Rd., Xi’an, shaanxi Province 710049, China
1 shared publication
Latest Publications
- Open Access
- 6 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 8743-8753
Experiment Study on Small Leak Detection and Diagnosis for Propulsion System Pipelines of Sounding Rocket
The small leak in the propulsion system pipeline of the sounding rocket is prone to occur in the connections because of the screw thread loosening. Due to economic and technical bottleneck, the traditional soap bubble method is widely used in practice to evaluate whether existing a leak or not by visually observing the bubble’s size and numbers. Thus doing so will result in the low inspection efficiency and high cost. Using acoustic emission (AE) techniques, this paper presents an experimental study on small leak detection on the screw thread connection in the propulsion system pipeline of sounding rocket. The time and frequency characteristics of the corresponding small leak AE signals are investigated. After characteristic indices extraction and selection, the multi-class support vector machines (MCSVM)-based leak rates recognition algorithm in One–vs–All (OVA) is proposed. It has been validated that, for the propulsion system pipeline of the sounding rocket, the dominant characteristic frequency band of the small leak AE signals induced by screw thread loosening concentrates on 35-45 kHz. The proposed optimal OVA SVM models can achieve good classification accuracy of >98% by using the characteristic index set {Envelope area, standard deviation (STD), root-mean-square (RMS), Energy, Average frequency} and Gaussian Radial Basis Function (RBF) kernel function. The drastic drops in the false alarm attribute to use the combination of time- and frequency-domain characteristic indices. Especially, once adding the “Envelope area” into the characteristic index set, the classification accuracies of the OVA SVM models are further improved significantly regardless of the effect of kernel functions.
- 6 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 8743-8753
Open AccessExperiment Study on Small Leak Detection and Diagnosis for Propulsion System Pipelines of Sounding Rocket
The small leak in the propulsion system pipeline of the sounding rocket is prone to occur in the connections because of the screw thread loosening. Due to economic and technical bottleneck, the traditional soap bubble method is widely used in practice to evaluate whether existing a leak or not by visually observing the bubble’s size and numbers. Thus doing so will result in the low inspection efficiency and high cost. Using acoustic emission (AE) techniques, this paper presents an experimental study on small leak detection on the screw thread connection in the propulsion system pipeline of sounding rocket. The time and frequency characteristics of the corresponding small leak AE signals are investigated. After characteristic indices extraction and selection, the multi-class support vector machines (MCSVM)-based leak rates recognition algorithm in One–vs–All (OVA) is proposed. It has been validated that, for the propulsion system pipeline of the sounding rocket, the dominant characteristic frequency band of the small leak AE signals induced by screw thread loosening concentrates on 35-45 kHz. The proposed optimal OVA SVM models can achieve good classification accuracy of >98% by using the characteristic index set {Envelope area, standard deviation (STD), root-mean-square (RMS), Energy, Average frequency} and Gaussian Radial Basis Function (RBF) kernel function. The drastic drops in the false alarm attribute to use the combination of time- and frequency-domain characteristic indices. Especially, once adding the “Envelope area” into the characteristic index set, the classification accuracies of the OVA SVM models are further improved significantly regardless of the effect of kernel functions.
- 19 November 2019
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 36 (1) , 35-61
AE source localization and imaging on cylindrical shell structures based on six-AE-sensor monitoring network and VTR focusing imaging
This study is interested in how to utilise the virtual time reversal (VTR) technique to locate the continuous AE source in cylindrical shell structure. Thus, a six-AE-sensor monitoring network was designed to divide cylindrical surface into two symmetric semi-cylindrical monitoring areas whose four vertexes and two geometrical centres were defined as the measuring points. The AE source can be located in certain semi-cylindrical monitoring area whose centre measuring point first captured the emitted AE signal. Besides, the response signals at other four measuring points were used to localise the AE source. To realise the VTR focusing of the AE signals, the proposed method solved two key problems. One is to search the shortest helical path between two arbitrary points on a cylindrical surface, which can provide the shortest distance from AE source to sensor. The other is to extract the specific frequency coefficients of wavelet transform for the continuous AE signal, which can meet with the requirement for the instantaneous abrupt characteristic of the signals to be processed using VTR focusing technique. Finally, a continuous leak experiment was carried out on a gas-filled steel pipe. The corresponding localisation method can accurately estimate the location of the continuous leak source.
- 19 November 2019
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 36 (1) , 35-61
AE source localization and imaging on cylindrical shell structures based on six-AE-sensor monitoring network and VTR focusing imaging
This study is interested in how to utilise the virtual time reversal (VTR) technique to locate the continuous AE source in cylindrical shell structure. Thus, a six-AE-sensor monitoring network was designed to divide cylindrical surface into two symmetric semi-cylindrical monitoring areas whose four vertexes and two geometrical centres were defined as the measuring points. The AE source can be located in certain semi-cylindrical monitoring area whose centre measuring point first captured the emitted AE signal. Besides, the response signals at other four measuring points were used to localise the AE source. To realise the VTR focusing of the AE signals, the proposed method solved two key problems. One is to search the shortest helical path between two arbitrary points on a cylindrical surface, which can provide the shortest distance from AE source to sensor. The other is to extract the specific frequency coefficients of wavelet transform for the continuous AE signal, which can meet with the requirement for the instantaneous abrupt characteristic of the signals to be processed using VTR focusing technique. Finally, a continuous leak experiment was carried out on a gas-filled steel pipe. The corresponding localisation method can accurately estimate the location of the continuous leak source.