Daniel Henrard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniel Henrard has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Yves Gossuin
Biomedical Physics Unit, Research Institute for Materials Science and Engineering, UMONS, Mons, Belgium
2 shared publications - Bernard Gallez
UCLouvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance, Avenue Mounier 73 B1.73.08, 1200 Brussels, Belgium
1 shared publication - Chrystelle Po
Université de Strasbourg, CNRS, ICUBE UMR 7357, 67000 Strasbourg, France
1 shared publication - Denis Nonclercq
University of Mons Pentagon building, Avenue du Champ de Mars 6
1 shared publication - Julie Magat
Univ. Bordeaux, INSERM, CRCTB, U 1045, IHU Liryc Bordeaux France
1 shared publication Maurice François Gonon
Department of Materials Science, University of Mons, Place du Parc 20, 7000 Mons, Belgium
1 shared publication
Latest Publications
- Open Access
- 19 November 2019
- Published by Wiley in Journal of Nanomaterials
- Vol. 2019, 1-9
Monitoring of Superparamagnetic Particle Sizes in the Langevin Law Regime
In this work, aqueous solutions of magnetite nanoparticles (NPs) are studied. Magnetite NPs are very useful in biomedicine for magnetic resonance imaging (MRI), for drug delivery therapy, and also for hyperthermia. In order to predict the NP efficiency in these applications, it is crucial to accurately characterize their size distribution and their magnetization. Magnetometry, through the dependence of NP magnetization on the magnetic induction (MB curve), can provide interesting information on these physical properties. In this work, the extraction of the NP size distribution and magnetization from experimental MB curves of aqueous solutions of magnetite NPs is discussed. The results are compared to TEM and XRD characterizations. It is shown that an expression taking into account the size distribution better fits the results than the commonly used simple Langevin function. The size distributions obtained by magnetometry seem comparable to those obtained by TEM measurements. However, a closer look at the results shows some nonnegligible discrepancies: the size distributions obtained by magnetometry vary with the temperature and are closer to the TEM ones at room temperature. Our study suggests that it could be explained by the nonnegligible anisotropy energy of the NPs at low temperature and the lack of NP Brownian rotation below the freezing point of water. This demonstrates that care must be taken when interpreting the results obtained by magnetometry of magnetite NPs: only the size and size distribution obtained at room temperature should be used.
- 19 November 2019
- Published by Wiley in Journal of Nanomaterials
- Vol. 2019, 1-9
Open AccessMonitoring of Superparamagnetic Particle Sizes in the Langevin Law Regime
In this work, aqueous solutions of magnetite nanoparticles (NPs) are studied. Magnetite NPs are very useful in biomedicine for magnetic resonance imaging (MRI), for drug delivery therapy, and also for hyperthermia. In order to predict the NP efficiency in these applications, it is crucial to accurately characterize their size distribution and their magnetization. Magnetometry, through the dependence of NP magnetization on the magnetic induction (MB curve), can provide interesting information on these physical properties. In this work, the extraction of the NP size distribution and magnetization from experimental MB curves of aqueous solutions of magnetite NPs is discussed. The results are compared to TEM and XRD characterizations. It is shown that an expression taking into account the size distribution better fits the results than the commonly used simple Langevin function. The size distributions obtained by magnetometry seem comparable to those obtained by TEM measurements. However, a closer look at the results shows some nonnegligible discrepancies: the size distributions obtained by magnetometry vary with the temperature and are closer to the TEM ones at room temperature. Our study suggests that it could be explained by the nonnegligible anisotropy energy of the NPs at low temperature and the lack of NP Brownian rotation below the freezing point of water. This demonstrates that care must be taken when interpreting the results obtained by magnetometry of magnetite NPs: only the size and size distribution obtained at room temperature should be used.
- 1 March 2015
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 252, 151-162
Theoretical and experimental study of ON-Resonance Saturation, an MRI sequence for positive contrast with superparamagnetic nanoparticles
- 1 March 2015
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 252, 151-162
Theoretical and experimental study of ON-Resonance Saturation, an MRI sequence for positive contrast with superparamagnetic nanoparticles