Mariraj Mohan Sundararajan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mariraj Mohan Sundararajan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
T. Swathi
Department of Civil Engineering Alagappa Chettiar Government College of Engineering and Technology Karaikudi India
4 shared publicationsS. Nagalakshmi
Department of Civil Engineering Alagappa Chettiar Government College of Engineering and Technology -630003 Karaikudi Tamilnadu India
2 shared publications- Amal Raj Stanislaus
Anna Univ, Ctr Environm Studies, Chennai, Tamil Nadu, India
1 shared publication N. Dharsika
Anna Univ, Ctr Environm Studies, Chennai, Tamil Nadu, India
1 shared publication- S. Nagalakshmi
Research Scholar, Alagappa Chettiar Government College of Engineering and Technology, Karaikudi, 630003, Tamilnadu, India
1 shared publication Swathi Thirunavukkarasan
Thanthai Periyar Government Institute of Technology, Vellore - 632002, Tamilnadu, India
1 shared publication
Latest Publications
- 10 June 2023
- Published by Wiley in Water and Environment Journal
- Vol. 38 (1) , 32-44
Evaluation of the effect of copper on the restart of a novel combined two‐stage anaerobic digester
The performance of the modified upflow anaerobic sludge blanket (MUASB) reactor–static granular bed reactor (SGBR) series was evaluated during the restart after a starvation period of 6 months. The steady‐state chemical oxygen demand (COD) removal of the reactor series obtained during the restart with copper was 98 ± 1.96% with the corresponding biogas production and copper removal of 0.218‐m3/kg CODdigested and 81.5%, respectively. Even though the biogas production of the reactor series with copper decreased because of the inhibitory effect of the accumulated copper on the methanogens, the reactor series was maintained stable throughout the operation with the effluent characteristics well within the discharge standards. The resumption of feed after starvation was sufficient for the recovery of the biomass from a dormant to an active state when operated with and without copper. The restart of the reactor series with copper was achieved in 35 days, indicating robustness and sustainability even after starvation.
- 10 June 2023
- Published by Wiley in Water and Environment Journal
- Vol. 38 (1) , 32-44
Evaluation of the effect of copper on the restart of a novel combined two‐stage anaerobic digester
The performance of the modified upflow anaerobic sludge blanket (MUASB) reactor–static granular bed reactor (SGBR) series was evaluated during the restart after a starvation period of 6 months. The steady‐state chemical oxygen demand (COD) removal of the reactor series obtained during the restart with copper was 98 ± 1.96% with the corresponding biogas production and copper removal of 0.218‐m3/kg CODdigested and 81.5%, respectively. Even though the biogas production of the reactor series with copper decreased because of the inhibitory effect of the accumulated copper on the methanogens, the reactor series was maintained stable throughout the operation with the effluent characteristics well within the discharge standards. The resumption of feed after starvation was sufficient for the recovery of the biomass from a dormant to an active state when operated with and without copper. The restart of the reactor series with copper was achieved in 35 days, indicating robustness and sustainability even after starvation.
- Open Access
- 2 June 2023
- Published by Korean Society of Environmental Engineering in Environmental Engineering Research
- Vol. 29 (2) , 230154
Enhanced membrane fouling control in a hybrid membrane bioreactor with coarse and fine pore sponge pre-filters
Membrane Bioreactors (MBR) have several advantages, but membrane fouling is a major disadvantage that prevents them from being widely used. Therefore, in the present study, the sponge was utilized as a pre-filter with coarse and fine pores in successive compartments before the membrane compartment and termed a “Hybrid-Membrane Bioreactor (H-MBR)”. In the present study, Conventional Membrane Bioreactor (C-MBR) and H-MBR were operated under similar operating conditions to evaluate the performance of H-MBR. The C-MBR experienced more frequent fouling within 60 days of operation, whereas in the H-MBR, the fouling was very low and gradual (i.e., 4.6 kPa at the end of 150 days of operation). Because of the low fouling, the need for cleaning was also eliminated for the stipulated operational period. The overall fouling rate of C-MBR and H-MBR was 5.83 kPa/d and 0.03 kPa/d, respectively. Both MBRs were good at organic pollutant removal. Because of the modification made in the present study, the H-MBR showed 14.66 times less cake layer resistance and 30 times less irreversible fouling resistance than the C-MBR. As a result, the H-MBR is effective in reducing both cake layer resistance and irreversible fouling resistance by retaining both cake-forming materials and irreversible foulants.
- 2 June 2023
- Published by Korean Society of Environmental Engineering in Environmental Engineering Research
- Vol. 29 (2) , 230154
Open AccessEnhanced membrane fouling control in a hybrid membrane bioreactor with coarse and fine pore sponge pre-filters
Membrane Bioreactors (MBR) have several advantages, but membrane fouling is a major disadvantage that prevents them from being widely used. Therefore, in the present study, the sponge was utilized as a pre-filter with coarse and fine pores in successive compartments before the membrane compartment and termed a “Hybrid-Membrane Bioreactor (H-MBR)”. In the present study, Conventional Membrane Bioreactor (C-MBR) and H-MBR were operated under similar operating conditions to evaluate the performance of H-MBR. The C-MBR experienced more frequent fouling within 60 days of operation, whereas in the H-MBR, the fouling was very low and gradual (i.e., 4.6 kPa at the end of 150 days of operation). Because of the low fouling, the need for cleaning was also eliminated for the stipulated operational period. The overall fouling rate of C-MBR and H-MBR was 5.83 kPa/d and 0.03 kPa/d, respectively. Both MBRs were good at organic pollutant removal. Because of the modification made in the present study, the H-MBR showed 14.66 times less cake layer resistance and 30 times less irreversible fouling resistance than the C-MBR. As a result, the H-MBR is effective in reducing both cake layer resistance and irreversible fouling resistance by retaining both cake-forming materials and irreversible foulants.
- 19 April 2023
- Published by Wiley in Water Environment Research
- Vol. 95 (4) , e10861
Enhanced membrane fouling control through self‐forming dynamic membrane and sponge‐wrapped membrane: A novel membrane bioreactor
Membrane technology offers a wide variety of advantages in wastewater treatment, but fouling impedes its widespread applications. Hence, in this study, a novel method was tried to control membrane fouling by combining the self‐forming dynamic membrane (SFDM) with a sponge‐wrapped membrane bioreactor. The configuration is termed a “Novel‐membrane bioreactor” (Novel‐MBR). To compare the performance of Novel‐MBR, a conventional membrane bioreactor (CMBR) was operated under similar operating conditions. CMBR and Novel‐MBR were run consequently for 60 and 150 days, respectively. The Novel‐MBR was composed of SFDMs in two compartments before a sponge‐wrapped membrane in the membrane compartment. In Novel‐MBR, the formation times for SFDMs on coarse (125 μm) and fine (37 μm) pore cloth filers were 43 and 13 min, respectively. The CMBR experienced more frequent fouling; the maximum fouling rate was 5.83 kPa/day. In CMBR, the membrane fouling due to cake layer resistance (6.92 × 1012 m−1) was high, and that alone contributed to 84% of fouling. In Novel‐MBR, the fouling rate was 0.0266 kPa/day, and the cake layer resistance was 0.329 × 1012 m−1. Also, the Novel‐MBR experienced 21 times less reversible fouling and 36 times less irreversible fouling resistance than the CMBR. In Novel‐MBR, the formed SFDM and the sponge wrapped on the membrane helped to reduce both reversible and irreversible fouling. With the modification tried in the present study, the Novel‐MBR experienced less fouling, and the maximum transmembrane pressure at the end of 150 days of operation was 4 kPa.Practitioner Points: CMBR experienced frequent fouling, and the maximum fouling rate was 5.83 kPa/day. Cake layer resistance was dominant in CMBR and contributed to 84% of fouling. The fouling rate of Novel‐MBR at the end of the operation was 0.0266 kPa/day. Novel‐MBR is expected to perform for ≈3380 days to reach the maximum TMP of 35 kPa.
- 19 April 2023
- Published by Wiley in Water Environment Research
- Vol. 95 (4) , e10861
Enhanced membrane fouling control through self‐forming dynamic membrane and sponge‐wrapped membrane: A novel membrane bioreactor
Membrane technology offers a wide variety of advantages in wastewater treatment, but fouling impedes its widespread applications. Hence, in this study, a novel method was tried to control membrane fouling by combining the self‐forming dynamic membrane (SFDM) with a sponge‐wrapped membrane bioreactor. The configuration is termed a “Novel‐membrane bioreactor” (Novel‐MBR). To compare the performance of Novel‐MBR, a conventional membrane bioreactor (CMBR) was operated under similar operating conditions. CMBR and Novel‐MBR were run consequently for 60 and 150 days, respectively. The Novel‐MBR was composed of SFDMs in two compartments before a sponge‐wrapped membrane in the membrane compartment. In Novel‐MBR, the formation times for SFDMs on coarse (125 μm) and fine (37 μm) pore cloth filers were 43 and 13 min, respectively. The CMBR experienced more frequent fouling; the maximum fouling rate was 5.83 kPa/day. In CMBR, the membrane fouling due to cake layer resistance (6.92 × 1012 m−1) was high, and that alone contributed to 84% of fouling. In Novel‐MBR, the fouling rate was 0.0266 kPa/day, and the cake layer resistance was 0.329 × 1012 m−1. Also, the Novel‐MBR experienced 21 times less reversible fouling and 36 times less irreversible fouling resistance than the CMBR. In Novel‐MBR, the formed SFDM and the sponge wrapped on the membrane helped to reduce both reversible and irreversible fouling. With the modification tried in the present study, the Novel‐MBR experienced less fouling, and the maximum transmembrane pressure at the end of 150 days of operation was 4 kPa.Practitioner Points: CMBR experienced frequent fouling, and the maximum fouling rate was 5.83 kPa/day. Cake layer resistance was dominant in CMBR and contributed to 84% of fouling. The fouling rate of Novel‐MBR at the end of the operation was 0.0266 kPa/day. Novel‐MBR is expected to perform for ≈3380 days to reach the maximum TMP of 35 kPa.
- 1 January 2023
- Published by OAIMDD - EcoZone Publishing House in Environmental Engineering and Management Journal
- Vol. 22 (7) , 1235-1243
ENHANCED COPPER REMOVAL AND BIOGAS PRODUCTION THROUGH INTERMITTENT OPERATION OF COUPLED MODIFIED UPFLOW WITH STATIC GRANULAR BED REACTOR TREATING COPPER-CONTAINING WASTEWATER
- 1 January 2023
- Published by OAIMDD - EcoZone Publishing House in Environmental Engineering and Management Journal
- Vol. 22 (7) , 1235-1243
ENHANCED COPPER REMOVAL AND BIOGAS PRODUCTION THROUGH INTERMITTENT OPERATION OF COUPLED MODIFIED UPFLOW WITH STATIC GRANULAR BED REACTOR TREATING COPPER-CONTAINING WASTEWATER
- 1 January 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 149 (1) , 04022088
Enhanced Degradation of the Substrate Using Modified Upflow Anaerobic Sludge Blanket Reactor–Static Granular Bed Reactor Series with Varying Hydraulic Retention Time at Lab Scale
The performance of a modified upflow anaerobic sludge blanket (MUASB) reactor with a modified three-phase separator and a rope matrix, combined with SGBR in series was analyzed for the treatment of synthetic wastewater. The performance of the reactor series in terms of chemical oxygen demand (COD) removal was evaluated by varying the operational hydraulic retention times (HRT) from 12 to 30 h. The optimum HRT for the reactor series was found to be 24 h, with a corresponding organic loading rate (OLR) of . The maximum overall COD removal of the reactor series of 98.75% was obtained with the corresponding overall biogas production of . The reactor series was found to be stable during the operational period in terms of volatile fatty acids (VFAs)/alkalinity ratio. The analytical hierarchy process was used for choosing a better treatment option among the alternatives based on the selected criteria. MUASB–static granular bed reactor (SGBR) series was found to be superior to the MUASB and the SGBR individually based on COD removal. The payback period for the reactor series was calculated to be 8 years (approximately). The MUASB-SGBR series was found to be robust, stable, and economical, with better performance in terms of COD removal.- 1 January 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 149 (1) , 04022088
Enhanced Degradation of the Substrate Using Modified Upflow Anaerobic Sludge Blanket Reactor–Static Granular Bed Reactor Series with Varying Hydraulic Retention Time at Lab Scale
The performance of a modified upflow anaerobic sludge blanket (MUASB) reactor with a modified three-phase separator and a rope matrix, combined with SGBR in series was analyzed for the treatment of synthetic wastewater. The performance of the reactor series in terms of chemical oxygen demand (COD) removal was evaluated by varying the operational hydraulic retention times (HRT) from 12 to 30 h. The optimum HRT for the reactor series was found to be 24 h, with a corresponding organic loading rate (OLR) of . The maximum overall COD removal of the reactor series of 98.75% was obtained with the corresponding overall biogas production of . The reactor series was found to be stable during the operational period in terms of volatile fatty acids (VFAs)/alkalinity ratio. The analytical hierarchy process was used for choosing a better treatment option among the alternatives based on the selected criteria. MUASB–static granular bed reactor (SGBR) series was found to be superior to the MUASB and the SGBR individually based on COD removal. The payback period for the reactor series was calculated to be 8 years (approximately). The MUASB-SGBR series was found to be robust, stable, and economical, with better performance in terms of COD removal.- Open Access
- 28 October 2022
- Published by Elsevier in Desalination and Water Treatment
- Vol. 268, 1-11
Hydrodynamic behaviour and treatment performance of the hybrid anaerobic baffled reactor
- 28 October 2022
- Published by Elsevier in Desalination and Water Treatment
- Vol. 268, 1-11
Open AccessHydrodynamic behaviour and treatment performance of the hybrid anaerobic baffled reactor
- 30 August 2022
- Published by Elsevier in Journal of Environmental Management
- Vol. 322, 116107
Performance evaluation of membrane bioreactor coupled with self-forming dynamic membrane
- 30 August 2022
- Published by Elsevier in Journal of Environmental Management
- Vol. 322, 116107
Performance evaluation of membrane bioreactor coupled with self-forming dynamic membrane
- 6 August 2022
- Published by Wiley in Water Environment Research
- Vol. 94 (8) , e10775
Enhanced biogas production and substrate degradation through the intermittent operation of modified upflow anaerobic sludge blanket–static granular bed reactor series
In the present study, the performance of a modified upflow anaerobic sludge blanket (MUASB) reactor–static granular bed reactor (SGBR) series in intermittent operation was analyzed for the treatment of synthetic wastewater. The reactor series was operated with a hydraulic retention time (HRT) of 24 h. The maximum chemical oxygen demand (COD) removal and biogas production of the reactor series obtained during the intermittent operation were 99 ± 0.29% and 0.529 ± 0.03 m3/kg CODdigested, respectively. One‐way analysis of variance (ANOVA) indicated a significant difference in biogas production during continuous and intermittent operations, whereas the COD removal was similar. Intermittent operation of the reactor series yielded a 56.05% increase in biogas production when compared with the continuous operation. The reactor series was maintained stable throughout the operational period. The maximum total suspended solids (TSS) removal and total nitrogen (TN) removal of the reactor series during the intermittent operation were 91.67% and 72.37%, respectively. Intermittent operation of the reactor series can be considered advantageous because of the reduced operational cost and enhanced biogas production in addition to COD removal.Practitioner Points: Intermittent operation of MUASB–SGBR series in terms of COD removal is evaluated. COD removal of reactor series was similar in intermittent and continuous operation. Biogas production in intermittent operation was superior to continuous operation. Reactor series performance is also compared with continuous operation using one‐way ANOVA.
- 6 August 2022
- Published by Wiley in Water Environment Research
- Vol. 94 (8) , e10775
Enhanced biogas production and substrate degradation through the intermittent operation of modified upflow anaerobic sludge blanket–static granular bed reactor series
In the present study, the performance of a modified upflow anaerobic sludge blanket (MUASB) reactor–static granular bed reactor (SGBR) series in intermittent operation was analyzed for the treatment of synthetic wastewater. The reactor series was operated with a hydraulic retention time (HRT) of 24 h. The maximum chemical oxygen demand (COD) removal and biogas production of the reactor series obtained during the intermittent operation were 99 ± 0.29% and 0.529 ± 0.03 m3/kg CODdigested, respectively. One‐way analysis of variance (ANOVA) indicated a significant difference in biogas production during continuous and intermittent operations, whereas the COD removal was similar. Intermittent operation of the reactor series yielded a 56.05% increase in biogas production when compared with the continuous operation. The reactor series was maintained stable throughout the operational period. The maximum total suspended solids (TSS) removal and total nitrogen (TN) removal of the reactor series during the intermittent operation were 91.67% and 72.37%, respectively. Intermittent operation of the reactor series can be considered advantageous because of the reduced operational cost and enhanced biogas production in addition to COD removal.Practitioner Points: Intermittent operation of MUASB–SGBR series in terms of COD removal is evaluated. COD removal of reactor series was similar in intermittent and continuous operation. Biogas production in intermittent operation was superior to continuous operation. Reactor series performance is also compared with continuous operation using one‐way ANOVA.
- 26 November 2021
- Published by Wiley in Water Environment Research
- Vol. 94 (1) , e1665
A review on upflow anaerobic sludge blanket reactor: Factors affecting performance, modification of configuration and its derivatives
The upflow anaerobic sludge blanket (UASB) reactor can be considered as one of the promising anaerobic wastewater treatment technologies suitable for the treatment of high‐strength wastewater. In the recent period, researchers have focused on the treatment of low‐strength wastewater using this technology. This review focuses on the key factors affecting the reactor performance such as hydraulic retention time (HRT), temperature, organic loading rate (OLR), pH and alkalinity, granulation, wastewater characteristics, mixing, and modification to conventional configuration. Start‐up and granulation played a major role in the determination of reactor performance, and various theories have been proposed to understand the mechanism of granulation. Correlation between start‐up time and OLR was found to be low, as other operating parameters might have been influencing the start‐up time. Flowchart depicting the development of UASB reactor over time is included. In the present work, further development and derivatives of the UASB reactor such as static granular bed reactor (SGBR) and expanded granular sludge bed (EGSB) reactor are analyzed. The optimal conditions for UASB for treating various types of substrates was found to be HRT of 3–24 h, OLR of 1–15 kg COD/m3/d, and operational temperature in mesophilic range (30–40°C). Analysis of various modifications that pave the way for identification of future areas of research to improve reactor performance is also presented.
- 26 November 2021
- Published by Wiley in Water Environment Research
- Vol. 94 (1) , e1665
A review on upflow anaerobic sludge blanket reactor: Factors affecting performance, modification of configuration and its derivatives
The upflow anaerobic sludge blanket (UASB) reactor can be considered as one of the promising anaerobic wastewater treatment technologies suitable for the treatment of high‐strength wastewater. In the recent period, researchers have focused on the treatment of low‐strength wastewater using this technology. This review focuses on the key factors affecting the reactor performance such as hydraulic retention time (HRT), temperature, organic loading rate (OLR), pH and alkalinity, granulation, wastewater characteristics, mixing, and modification to conventional configuration. Start‐up and granulation played a major role in the determination of reactor performance, and various theories have been proposed to understand the mechanism of granulation. Correlation between start‐up time and OLR was found to be low, as other operating parameters might have been influencing the start‐up time. Flowchart depicting the development of UASB reactor over time is included. In the present work, further development and derivatives of the UASB reactor such as static granular bed reactor (SGBR) and expanded granular sludge bed (EGSB) reactor are analyzed. The optimal conditions for UASB for treating various types of substrates was found to be HRT of 3–24 h, OLR of 1–15 kg COD/m3/d, and operational temperature in mesophilic range (30–40°C). Analysis of various modifications that pave the way for identification of future areas of research to improve reactor performance is also presented.
- 2 November 2017
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series A
- Vol. 98 (4) , 545-553
Vermicomposting of Paper Mill Sludge with Eisenia fetida for its Conversion to Nutrient Using Different Seed Materials
- 2 November 2017
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series A
- Vol. 98 (4) , 545-553
Vermicomposting of Paper Mill Sludge with Eisenia fetida for its Conversion to Nutrient Using Different Seed Materials