Kuan Tao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kuan Tao has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Junqiang Qiu
Department of Exercise Biochemistry, Exercise Science School, Beijing Sport University, Beijing 100084, China
4 shared publications - Lixin Sun
AI Sports Engineering Lab, School of Sports Engineering, Beijing Sport University, Beijing, China
4 shared publications Junchao Yang
School of Sport Science, Beijing Sport University, Beijing, China
3 shared publicationsYanfei Shen
3 shared publicationsFei Liu
School of Sports Engineering, Beijing Sport University, Beijing, China
2 shared publications- Feng Liu
Key Laboratory of Hebei Province for Molecular Biophysics, Institute of Biophysics, School of Health Science & Biomedical Engineering, Hebei University of Technology, Tianjin, 300130, CHINA
2 shared publications
Latest Publications
- Open Access
Ternary Spiking Neural Networks Enhanced by Complemented Neurons and Membrane Potential Aggregation
Spiking Neural Networks (SNNs) are promising energy-efficient models and powerful framworks of modeling neuron dynamics. However, existing binary spiking neurons exhibit limited biological plausibilities and low information capacity. Recently developed ternary spiking neuron possesses higher consistency with biological principles (i.e. excitation-inhibition balance mechanism). Despite of this, the ternary spiking neuron suffers from defects including iterative information loss, temporal gradient vanishing and irregular distributions of membrane potentials. To address these issues, we propose Complemented Ternary Spiking Neuron (CTSN), a novel ternary spiking neuron model that incorporates an learnable complemental term to store information from historical inputs. CTSN effectively improves the deficiencies of ternary spiking neuron, while the embedded learnable factors enable CTSN to adaptively adjust neuron dynamics, providing strong neural heterogeneity. Furthermore, based on the temporal evolution features of ternary spiking neurons' membrane potential distributions, we propose the Temporal Membrane Potential Regularization (TMPR) training method. TMPR introduces time-varying regularization strategy utilizing membrane potentials, furhter enhancing the training process by creating extra backpropagation paths. We validate our methods through extensive experiments on various datasets, demonstrating remarkable performance advances.
Open AccessTernary Spiking Neural Networks Enhanced by Complemented Neurons and Membrane Potential Aggregation
Spiking Neural Networks (SNNs) are promising energy-efficient models and powerful framworks of modeling neuron dynamics. However, existing binary spiking neurons exhibit limited biological plausibilities and low information capacity. Recently developed ternary spiking neuron possesses higher consistency with biological principles (i.e. excitation-inhibition balance mechanism). Despite of this, the ternary spiking neuron suffers from defects including iterative information loss, temporal gradient vanishing and irregular distributions of membrane potentials. To address these issues, we propose Complemented Ternary Spiking Neuron (CTSN), a novel ternary spiking neuron model that incorporates an learnable complemental term to store information from historical inputs. CTSN effectively improves the deficiencies of ternary spiking neuron, while the embedded learnable factors enable CTSN to adaptively adjust neuron dynamics, providing strong neural heterogeneity. Furthermore, based on the temporal evolution features of ternary spiking neurons' membrane potential distributions, we propose the Temporal Membrane Potential Regularization (TMPR) training method. TMPR introduces time-varying regularization strategy utilizing membrane potentials, furhter enhancing the training process by creating extra backpropagation paths. We validate our methods through extensive experiments on various datasets, demonstrating remarkable performance advances.
- Open Access
Energy-Expenditure Estimation During Aerobic Training Sessions for Badminton Players
This study investigated differences in energy-expenditure (EE) modeling between badminton players of varying competitive levels during aerobic training. It evaluated the impact of sensor quantity and sample size on prediction model accuracy and generalizability, providing evidence for personalized training-load monitoring. Fifty badminton players (25 elite, 25 enthusiasts) performed treadmill running, cycling, rope skipping, and stair walking. Data were collected using accelerometers (waist, wrists, ankles), a heart rate monitor, and indirect calorimetry (criterion EE). Multiple machine learning models (Linear Regression, Bayesian Ridge Regression, Random Forest, Gradient Boosting) were employed to develop EE prediction models. Performance was assessed using R2, mean absolute percentage error (MAPE), and root mean square error (RMSE), with further evaluation via the Triple-E framework (Effectiveness, Efficiency, Extension). Elite athletes demonstrated stable, coordinated movement patterns, achieving the best values for R2 and the smallest errors using minimal core sensors (typically dominant side). Enthusiasts required multi-site sensors to compensate for greater execution variability. Increasing sensors beyond three yielded no performance gains; optimal configurations involved 2–3 core accelerometers combined with heart rate data. Expanding sample size significantly enhanced model stability and generalizability (e.g., running task R2 increased from 0.49 (N = 20) to 0.95 (N = 40)). Triple-E evaluation indicated that strategic sensor minimization coupled with sufficient sample size maximized predictive performance while reducing computational cost and deployment burden. Competitive level significantly influences EE modeling requirements. Elite athletes are suited to a “low-sensor, small-sample” scenario, whereas enthusiasts necessitate a “multi-sensor, large-sample” strategy.
Open AccessEnergy-Expenditure Estimation During Aerobic Training Sessions for Badminton Players
This study investigated differences in energy-expenditure (EE) modeling between badminton players of varying competitive levels during aerobic training. It evaluated the impact of sensor quantity and sample size on prediction model accuracy and generalizability, providing evidence for personalized training-load monitoring. Fifty badminton players (25 elite, 25 enthusiasts) performed treadmill running, cycling, rope skipping, and stair walking. Data were collected using accelerometers (waist, wrists, ankles), a heart rate monitor, and indirect calorimetry (criterion EE). Multiple machine learning models (Linear Regression, Bayesian Ridge Regression, Random Forest, Gradient Boosting) were employed to develop EE prediction models. Performance was assessed using R2, mean absolute percentage error (MAPE), and root mean square error (RMSE), with further evaluation via the Triple-E framework (Effectiveness, Efficiency, Extension). Elite athletes demonstrated stable, coordinated movement patterns, achieving the best values for R2 and the smallest errors using minimal core sensors (typically dominant side). Enthusiasts required multi-site sensors to compensate for greater execution variability. Increasing sensors beyond three yielded no performance gains; optimal configurations involved 2–3 core accelerometers combined with heart rate data. Expanding sample size significantly enhanced model stability and generalizability (e.g., running task R2 increased from 0.49 (N = 20) to 0.95 (N = 40)). Triple-E evaluation indicated that strategic sensor minimization coupled with sufficient sample size maximized predictive performance while reducing computational cost and deployment burden. Competitive level significantly influences EE modeling requirements. Elite athletes are suited to a “low-sensor, small-sample” scenario, whereas enthusiasts necessitate a “multi-sensor, large-sample” strategy.
- 29 August 2025
- Published by Springer Nature in Journal of Science in Sport and Exercise
- p. 1-10
Validity of Smartwatches for Estimating Energy Expenditure During Aerobic Dance
- 29 August 2025
- Published by Springer Nature in Journal of Science in Sport and Exercise
- p. 1-10
Validity of Smartwatches for Estimating Energy Expenditure During Aerobic Dance
- Open Access
- 29 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 2088-2096
Triple-E Principle: Leveraging Occam’s Razor for Dance Energy Expenditure Estimation
Objective: Dance, as a globally practiced physical activity, presents challenges in accurately assessing energy expenditure due to its diverse styles and tempos. Traditional methods, relying on empirical formulas within ActiGraph accelerometers, often result in significant biases. While multiple wearable sensors have been introduced to mitigate these biases, they increase model complexity. Methods: This study proposes the Triple-E principle—Effectiveness, Efficiency, and Extension—as a framework for developing state-of-the-art (SOTA) machine learning models aimed at accurately estimating energy expenditure, while minimizing model complexity and optimizing sensor placement. To validate the proposed approach, we recruited a cohort of 250 participants (mean age: 63.0 ± 6.0 years), each performing ballroom, aerobic, or square dance routines. Participants were fitted with ActiGraph wGT3X-BT accelerometers at five anatomical locations, along with the CORTEX MetaMax 3B gas analyzer for metabolic data collection. We analyzed 311 physiological signal sequences and 1,555 acceleration count sequences. Results: Empirical formulas were proved inaccurate for dance energy expenditure, with Mean Absolute Percentage Error (MAPE) exceeding 50% and Root Mean Squared Error (RMSE) surpassing 3.23. A bidirectional stepwise regression model incorporating heart rate or triaxial motion sequences from accelerometers achieved an average goodness-of-fit of 0.73, identifying optimal accelerometer sites based on Efficiency principle. A random forest regression model minimized errors to 5% (MAPE) and 0.33 (RMSE) with data from all sites. Notably, wrist accelerometers and heart rate alone provided sufficient accuracy (RMSE: 0.35-0.36), highlighting a trade-off between Effectiveness and Efficiency. A deep-learning network pipeline based on the Extension principle automatically extracted features, achieving an average RMSE to 0.15. Conclusion: This study introduces a pioneering quantitative and unified model assessment system. Thoroughly analyzed and validated in the context of dance, the research offers detailed explanations of the most effective, efficient, and extensive models.
- 29 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 2088-2096
Open AccessTriple-E Principle: Leveraging Occam’s Razor for Dance Energy Expenditure Estimation
Objective: Dance, as a globally practiced physical activity, presents challenges in accurately assessing energy expenditure due to its diverse styles and tempos. Traditional methods, relying on empirical formulas within ActiGraph accelerometers, often result in significant biases. While multiple wearable sensors have been introduced to mitigate these biases, they increase model complexity. Methods: This study proposes the Triple-E principle—Effectiveness, Efficiency, and Extension—as a framework for developing state-of-the-art (SOTA) machine learning models aimed at accurately estimating energy expenditure, while minimizing model complexity and optimizing sensor placement. To validate the proposed approach, we recruited a cohort of 250 participants (mean age: 63.0 ± 6.0 years), each performing ballroom, aerobic, or square dance routines. Participants were fitted with ActiGraph wGT3X-BT accelerometers at five anatomical locations, along with the CORTEX MetaMax 3B gas analyzer for metabolic data collection. We analyzed 311 physiological signal sequences and 1,555 acceleration count sequences. Results: Empirical formulas were proved inaccurate for dance energy expenditure, with Mean Absolute Percentage Error (MAPE) exceeding 50% and Root Mean Squared Error (RMSE) surpassing 3.23. A bidirectional stepwise regression model incorporating heart rate or triaxial motion sequences from accelerometers achieved an average goodness-of-fit of 0.73, identifying optimal accelerometer sites based on Efficiency principle. A random forest regression model minimized errors to 5% (MAPE) and 0.33 (RMSE) with data from all sites. Notably, wrist accelerometers and heart rate alone provided sufficient accuracy (RMSE: 0.35-0.36), highlighting a trade-off between Effectiveness and Efficiency. A deep-learning network pipeline based on the Extension principle automatically extracted features, achieving an average RMSE to 0.15. Conclusion: This study introduces a pioneering quantitative and unified model assessment system. Thoroughly analyzed and validated in the context of dance, the research offers detailed explanations of the most effective, efficient, and extensive models.
- Open Access
- 7 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-14
Validity of Hera Leto consumer earbuds for heart rate monitoring during stationary cycling
Heart rate (HR) monitoring using earbuds presents a promising avenue for precise measurement, yet its validity remains under investigation during stationary cycling. In this study, we assessed the validity of the Hera Leto consumer earbuds by enrolling twenty-eight athletes as participants. Each participant wore a chest-strap Polar H10, considered the gold-standard reference, while simultaneously testing three HR monitors: the Hera Leto (worn on the ears), the Polar Verity Sense (worn on the upper arm), and the Polar Vantage V (worn on the wrist). The exercise protocol included four steady-state exercise sessions, six sessions of severe intensity exhaustive exercise, and three high-intensity interval training (HIIT) sessions. Our findings revealed a robust correlation (\(\:r\)=0.970, \(\:P\)<0.001) between the HR measurements obtained from Hera Leto and Polar H10 across all exercise intensities, with a minimal systematic bias of − 0.67 bpm. with a minimal systematic bias of -0.67 bpm. Notably, Hera Leto demonstrated superior performance, with a mean absolute error (MAE) of 2 bpm and concordance correlation coefficient (CCC) of 0.97, compared to the Polar Verity Sense (MAE = 4 bpm, CCC = 0.88) and Polar Vantage V (MAE = 4 bpm, CCC = 0.93). Although the precision of HR measurement decreased with increasing exercise intensity, Hera Leto exhibited a slower onset of this decline compared to the other devices. Overall, our study underscores the potential of Hera Leto earbuds as a valid tool for HR monitoring, particularly in scenarios involving steady-state exercise.- 7 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-14
Open AccessValidity of Hera Leto consumer earbuds for heart rate monitoring during stationary cycling
Heart rate (HR) monitoring using earbuds presents a promising avenue for precise measurement, yet its validity remains under investigation during stationary cycling. In this study, we assessed the validity of the Hera Leto consumer earbuds by enrolling twenty-eight athletes as participants. Each participant wore a chest-strap Polar H10, considered the gold-standard reference, while simultaneously testing three HR monitors: the Hera Leto (worn on the ears), the Polar Verity Sense (worn on the upper arm), and the Polar Vantage V (worn on the wrist). The exercise protocol included four steady-state exercise sessions, six sessions of severe intensity exhaustive exercise, and three high-intensity interval training (HIIT) sessions. Our findings revealed a robust correlation (\(\:r\)=0.970, \(\:P\)<0.001) between the HR measurements obtained from Hera Leto and Polar H10 across all exercise intensities, with a minimal systematic bias of − 0.67 bpm. with a minimal systematic bias of -0.67 bpm. Notably, Hera Leto demonstrated superior performance, with a mean absolute error (MAE) of 2 bpm and concordance correlation coefficient (CCC) of 0.97, compared to the Polar Verity Sense (MAE = 4 bpm, CCC = 0.88) and Polar Vantage V (MAE = 4 bpm, CCC = 0.93). Although the precision of HR measurement decreased with increasing exercise intensity, Hera Leto exhibited a slower onset of this decline compared to the other devices. Overall, our study underscores the potential of Hera Leto earbuds as a valid tool for HR monitoring, particularly in scenarios involving steady-state exercise. - Open Access
Combined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction
Oxygen uptake () is an essential metric for evaluating cardiopulmonary health and athletic performance, which can barely be directly measured. Heart rate () is a prominent physiological indicator correlated with and is often used for indirect prediction. This study investigates the impact of placement on prediction accuracy by analyzing data combined with the respiratory rate () and minute ventilation () from three anatomical locations: the chest; arm; and wrist. Twenty-eight healthy adults participated in incremental and constant workload cycling tests at various intensities. Data on , , , and were collected and used to develop a neural network model for prediction. The influence of position on prediction accuracy was assessed via Bland–Altman plots, and model performance was evaluated by mean absolute error (MAE), coefficient of determination (R2), and mean absolute percentage error (MAPE). Our findings indicate that combined with and () produces the most accurate predictions (MAE: 165 mL/min, R2: 0.87, MAPE: 15.91%). Notably, as exercise intensity increases, the accuracy of prediction decreases, particularly within high-intensity exercise. The substitution of with different anatomical sites significantly impacts prediction accuracy, with wrist placement showing a more profound effect compared to arm placement. In conclusion, this study underscores the importance of considering placement in prediction models, with and serving as effective compensatory factors. These findings contribute to refining indirect estimation methods, enhancing their predictive capabilities across different exercise intensities and anatomical placements.Open AccessCombined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction
Oxygen uptake () is an essential metric for evaluating cardiopulmonary health and athletic performance, which can barely be directly measured. Heart rate () is a prominent physiological indicator correlated with and is often used for indirect prediction. This study investigates the impact of placement on prediction accuracy by analyzing data combined with the respiratory rate () and minute ventilation () from three anatomical locations: the chest; arm; and wrist. Twenty-eight healthy adults participated in incremental and constant workload cycling tests at various intensities. Data on , , , and were collected and used to develop a neural network model for prediction. The influence of position on prediction accuracy was assessed via Bland–Altman plots, and model performance was evaluated by mean absolute error (MAE), coefficient of determination (R2), and mean absolute percentage error (MAPE). Our findings indicate that combined with and () produces the most accurate predictions (MAE: 165 mL/min, R2: 0.87, MAPE: 15.91%). Notably, as exercise intensity increases, the accuracy of prediction decreases, particularly within high-intensity exercise. The substitution of with different anatomical sites significantly impacts prediction accuracy, with wrist placement showing a more profound effect compared to arm placement. In conclusion, this study underscores the importance of considering placement in prediction models, with and serving as effective compensatory factors. These findings contribute to refining indirect estimation methods, enhancing their predictive capabilities across different exercise intensities and anatomical placements. - 21 February 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 92
Intelligent fatigue detection based on hierarchical multi-scale ECG representations and HRV measures
- 21 February 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 92
Intelligent fatigue detection based on hierarchical multi-scale ECG representations and HRV measures
- 4 February 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 91, 106033
Decoding invariant spatiotemporal synergy patterns on muscle networks of lower-limb movements via surface electromyographic signals
- 4 February 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 91, 106033
Decoding invariant spatiotemporal synergy patterns on muscle networks of lower-limb movements via surface electromyographic signals
- Open Access
- 12 July 2023
- Published by Springer Nature in BMC Geriatrics
- Vol. 23 (1) , 1-10
Possible-sarcopenic screening with disturbed plasma amino acid profile in the elderly
Background: The mass and strength of skeletal muscle decline with age, leading to its progressive dysfunction. High-throughput metabolite profiling provides the opportunity to reveal metabolic mechanisms and the identification of biomarkers. However, the role of amino acid metabolism in possible sarcopenia remains unclear. Objectives: The aim of this study included exploring variations in plasma amino acid concentrations in elderly individuals who have possible sarcopenia and further attempting to characterize a distinctive plasma amino acid profile through targeted metabolomics. Methods: A cross-sectional, correlational research design was used for this study. Thirty possible-sarcopenic elderly participants were recruited (n = 30), as determined by the Asian Working Group for Sarcopenia (AWGS). Meanwhile, a reference group of non-sarcopenic (sex-, age-, and Appendicular Skeletal muscle Mass Index (ASMI)-matched non-sarcopenic controls, n = 36) individuals was included to compare the potential differences in metabolic fingerprint of the plasma amino acids associated with sarcopenia. Both groups were conducted the body composition analysis, physical function examination, and plasma amino acid-targeted metabolomics. The amino acids in plasma were measured using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS–MS). Also, orthogonal partial least-squares-discriminant analysis (OPLS-DA) was applied to characterize the plasma amino acid profile. Results: With respect to Handgrip Strength (HGS), the Five-Repetition Chair Stand Test (CS-5), the Six-Minute Walking Test (6MWT), the arm curl, the 30 s-Chair Stand Test (CST), the 2-Minute Step Test (2MST), the Timed Up-and-Go Test (TUGT), there was a decline in skeletal muscle function in the possible-sarcopenic group compared to the non-sarcopenic group. The mean plasma concentrations of arginine, asparagine, phenylalanine, serine, lysine, glutamine, and threonine were significantly lower in the possible sarcopenia group, whereas cirulline, proline, serine, and glutamic acid concentrations were higher. According to the multi-analysis, glutamine, serine, lysine, threonine, and proline were determined as the potential markers that indicated possible sarcopenia. Conclusions: The findings characterize significantly altered plasma amino acid metabolisms in the elderly with possible sarcopenia, which aids to screening people who are at a high risk of developing condition, and motivating to design new preventive and therapeutic approaches.
- 12 July 2023
- Published by Springer Nature in BMC Geriatrics
- Vol. 23 (1) , 1-10
Open AccessPossible-sarcopenic screening with disturbed plasma amino acid profile in the elderly
Background: The mass and strength of skeletal muscle decline with age, leading to its progressive dysfunction. High-throughput metabolite profiling provides the opportunity to reveal metabolic mechanisms and the identification of biomarkers. However, the role of amino acid metabolism in possible sarcopenia remains unclear. Objectives: The aim of this study included exploring variations in plasma amino acid concentrations in elderly individuals who have possible sarcopenia and further attempting to characterize a distinctive plasma amino acid profile through targeted metabolomics. Methods: A cross-sectional, correlational research design was used for this study. Thirty possible-sarcopenic elderly participants were recruited (n = 30), as determined by the Asian Working Group for Sarcopenia (AWGS). Meanwhile, a reference group of non-sarcopenic (sex-, age-, and Appendicular Skeletal muscle Mass Index (ASMI)-matched non-sarcopenic controls, n = 36) individuals was included to compare the potential differences in metabolic fingerprint of the plasma amino acids associated with sarcopenia. Both groups were conducted the body composition analysis, physical function examination, and plasma amino acid-targeted metabolomics. The amino acids in plasma were measured using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS–MS). Also, orthogonal partial least-squares-discriminant analysis (OPLS-DA) was applied to characterize the plasma amino acid profile. Results: With respect to Handgrip Strength (HGS), the Five-Repetition Chair Stand Test (CS-5), the Six-Minute Walking Test (6MWT), the arm curl, the 30 s-Chair Stand Test (CST), the 2-Minute Step Test (2MST), the Timed Up-and-Go Test (TUGT), there was a decline in skeletal muscle function in the possible-sarcopenic group compared to the non-sarcopenic group. The mean plasma concentrations of arginine, asparagine, phenylalanine, serine, lysine, glutamine, and threonine were significantly lower in the possible sarcopenia group, whereas cirulline, proline, serine, and glutamic acid concentrations were higher. According to the multi-analysis, glutamine, serine, lysine, threonine, and proline were determined as the potential markers that indicated possible sarcopenia. Conclusions: The findings characterize significantly altered plasma amino acid metabolisms in the elderly with possible sarcopenia, which aids to screening people who are at a high risk of developing condition, and motivating to design new preventive and therapeutic approaches.
- Open Access
A Comprehensive Analysis of the Validity and Reliability of the Perception Neuron Studio for Upper-Body Motion Capture
The Perception Neuron Studio (PNS) is a cost-effective and widely used inertial motion capture system. However, a comprehensive analysis of its upper-body motion capture accuracy is still lacking, before it is being applied to biomechanical research. Therefore, this study first evaluated the validity and reliability of this system in upper-body capturing and then quantified the system’s accuracy for different task complexities and movement speeds. Seven participants performed simple (eight single-DOF upper-body movements) and complex tasks (lifting a 2.5 kg box over the shoulder) at fast and slow speeds with the PNS and OptiTrack (gold-standard optical system) collecting kinematics data simultaneously. Statistical metrics such as CMC, RMSE, Pearson’s r, R2, and Bland–Altman analysis were utilized to assess the similarity between the two systems. Test–retest reliability included intra- and intersession relations, which were assessed by the intraclass correlation coefficient (ICC) as well as CMC. All upper-body kinematics were highly consistent between the two systems, with CMC values 0.73–0.99, RMSE 1.9–12.5°, Pearson’s r 0.84–0.99, R2 0.75–0.99, and Bland–Altman analysis demonstrating a bias of 0.2–27.8° as well as all the points within 95% limits of agreement (LOA). The relative reliability of intra- and intersessions was good to excellent (i.e., ICC and CMC were 0.77–0.99 and 0.75–0.98, respectively). The paired t-test revealed that faster speeds resulted in greater bias, while more complex tasks led to lower consistencies. Our results showed that the PNS could provide accurate enough upper-body kinematics for further biomechanical performance analysis.
Open AccessA Comprehensive Analysis of the Validity and Reliability of the Perception Neuron Studio for Upper-Body Motion Capture
The Perception Neuron Studio (PNS) is a cost-effective and widely used inertial motion capture system. However, a comprehensive analysis of its upper-body motion capture accuracy is still lacking, before it is being applied to biomechanical research. Therefore, this study first evaluated the validity and reliability of this system in upper-body capturing and then quantified the system’s accuracy for different task complexities and movement speeds. Seven participants performed simple (eight single-DOF upper-body movements) and complex tasks (lifting a 2.5 kg box over the shoulder) at fast and slow speeds with the PNS and OptiTrack (gold-standard optical system) collecting kinematics data simultaneously. Statistical metrics such as CMC, RMSE, Pearson’s r, R2, and Bland–Altman analysis were utilized to assess the similarity between the two systems. Test–retest reliability included intra- and intersession relations, which were assessed by the intraclass correlation coefficient (ICC) as well as CMC. All upper-body kinematics were highly consistent between the two systems, with CMC values 0.73–0.99, RMSE 1.9–12.5°, Pearson’s r 0.84–0.99, R2 0.75–0.99, and Bland–Altman analysis demonstrating a bias of 0.2–27.8° as well as all the points within 95% limits of agreement (LOA). The relative reliability of intra- and intersessions was good to excellent (i.e., ICC and CMC were 0.77–0.99 and 0.75–0.98, respectively). The paired t-test revealed that faster speeds resulted in greater bias, while more complex tasks led to lower consistencies. Our results showed that the PNS could provide accurate enough upper-body kinematics for further biomechanical performance analysis.