Ryan Hong Soon Tay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryan Hong Soon Tay has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Chew Beng Soh
Engineering Cluster, Singapore Institute of Technology, Singapore 138683, Singapore
2 shared publications - Barbara Ting Wei Ang
Engineering Cluster, Singapore Institute of Technology, 1 Punggol Coast Road, Singapore 828608, Singapore
1 shared publication - David Tan
NetaTech Engineering Pte Ltd., 512 Chai Chee Lane #06-04, Singapore 469028, Singapore
1 shared publication - Hikaru Kobayashi
Tohoku University
1 shared publication - Hui An
Engineering Cluster, Singapore Institute of Technology, 1 Punggol Coast Road, Singapore 828608, Singapore
1 shared publication - Jerome Wei Chiang Teng
Sustainable Infrastructure Engineering (Building Services) Progamme, Singapore Institute of Technology, 10 Dover Drive, Singapore 138683, Singapore
1 shared publication
Latest Publications
- Open Access
- 16 December 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (24) , 16885
Urban-Metabolic Farming Modules on Rooftops for Eco-Resilient Farmscape
The scarcity of land resources and food security challenges have prompted more effective uses of the rooftop as well as façade spaces in the urban city of Singapore. Urban rooftop spaces are used for mechanical and electrical (M&E) amenities such as air-conditioning cooling units and water tanks, so the spacious span of the roof area on HDB flats in Singapore is not available. Urban-metabolic farming modules (UmFm) built on 1.5 to 2 m terrace-step terrains have been modelled using BIM Revit to mimic such constraints in rooftop spaces. CFD simulation was conducted for the structure with consideration of the prevailing wind directions at different months of the year. The airflow with the inclusion of mesh netting and varying tiltings of the polycarbonate side façade was simulated to understand their impact on airflow in the growth envelope of the UmFm units under different prevailing wind directions. The amount of solar irradiance received by the crops at different heights in the UmFm due to the sun’s path, and shading of crops grown on the A-frame, was studied using Climate Studio. A comparative verification was done with a scaffold modular unit mounted with temperature, humidity, airflow, and Photosynthesis Photon Flux Density (PPFD) sensors. The digital model of the UmFm unit enables a prior assessment of site feasibility before actual physical implementation on an existing rooftop. It also facilitates plug and play for the UmFm unit to generate an eco-resilient farmscape for an urban city.
- 16 December 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (24) , 16885
Open AccessUrban-Metabolic Farming Modules on Rooftops for Eco-Resilient Farmscape
The scarcity of land resources and food security challenges have prompted more effective uses of the rooftop as well as façade spaces in the urban city of Singapore. Urban rooftop spaces are used for mechanical and electrical (M&E) amenities such as air-conditioning cooling units and water tanks, so the spacious span of the roof area on HDB flats in Singapore is not available. Urban-metabolic farming modules (UmFm) built on 1.5 to 2 m terrace-step terrains have been modelled using BIM Revit to mimic such constraints in rooftop spaces. CFD simulation was conducted for the structure with consideration of the prevailing wind directions at different months of the year. The airflow with the inclusion of mesh netting and varying tiltings of the polycarbonate side façade was simulated to understand their impact on airflow in the growth envelope of the UmFm units under different prevailing wind directions. The amount of solar irradiance received by the crops at different heights in the UmFm due to the sun’s path, and shading of crops grown on the A-frame, was studied using Climate Studio. A comparative verification was done with a scaffold modular unit mounted with temperature, humidity, airflow, and Photosynthesis Photon Flux Density (PPFD) sensors. The digital model of the UmFm unit enables a prior assessment of site feasibility before actual physical implementation on an existing rooftop. It also facilitates plug and play for the UmFm unit to generate an eco-resilient farmscape for an urban city.
- Open Access
- 9 June 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (12) , 7089
Effects of Agrivoltaic Systems on the Surrounding Rooftop Microclimate
Agrivoltaic systems have the potential to maximize the usefulness of spaces in building rooftops. Urban farming systems improve the microclimatic conditions, which are beneficial to solar photovoltaic (PV) systems, as they lower the operating temperatures, resulting in a higher operating efficiency. Microclimate simulations by means of ENVI-met simulation showed that between 0800 h and 1800 h, PV temperatures in the plot that has crops below the PV system were on average lower by 2.83 °C and 0.71 °C as compared without crops on a typical sunny and cloudy day, respectively. Hence, we may see PV efficiency performance improvement of 1.13–1.42% and 0.28–0.35% on a sunny day and cloudy day, respectively. Data collected from a physical prototype of an agrivoltaic system suggested that evaporative cooling was responsible for the reduction in ambient temperatures. The presence of crops growing underneath the PV canopy resulted in the agrivoltaic prototype generating between 3.05 and 3.2% more energy over the day as compared to a control system with no crops underneath.
- 9 June 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (12) , 7089
Open AccessEffects of Agrivoltaic Systems on the Surrounding Rooftop Microclimate
Agrivoltaic systems have the potential to maximize the usefulness of spaces in building rooftops. Urban farming systems improve the microclimatic conditions, which are beneficial to solar photovoltaic (PV) systems, as they lower the operating temperatures, resulting in a higher operating efficiency. Microclimate simulations by means of ENVI-met simulation showed that between 0800 h and 1800 h, PV temperatures in the plot that has crops below the PV system were on average lower by 2.83 °C and 0.71 °C as compared without crops on a typical sunny and cloudy day, respectively. Hence, we may see PV efficiency performance improvement of 1.13–1.42% and 0.28–0.35% on a sunny day and cloudy day, respectively. Data collected from a physical prototype of an agrivoltaic system suggested that evaporative cooling was responsible for the reduction in ambient temperatures. The presence of crops growing underneath the PV canopy resulted in the agrivoltaic prototype generating between 3.05 and 3.2% more energy over the day as compared to a control system with no crops underneath.
- 3 November 2015
- Published by Springer Nature in Dairy Science & Technology
- Vol. 96 (3) , 285-295
Characterisation and biofilm screening of the predominant bacteria isolated from whey protein concentrate 80
- 3 November 2015
- Published by Springer Nature in Dairy Science & Technology
- Vol. 96 (3) , 285-295
Characterisation and biofilm screening of the predominant bacteria isolated from whey protein concentrate 80