Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aris Tsangrassoulis has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and Development of a Low-Cost Educational Platform for Investigating Human-Centric Lighting (HCL) Settings

    by George K. Adam, Aris Tsangrassoulis

    The design of reliable and accurate indoor lighting control systems for LEDs’ (light-emitting diodes) color temperature and brightness, in an effort to affect human circadian rhythms, has been emerging in the last few years. However, this is quite challenging since parameters, such as the melanopic equivalent daylight illuminance (mEDI), have to be evaluated in real time, using illuminance values and the spectrum of incident light. In this work, to address these issues, a prototype platform has been built based on the low-cost and low-power Arduino UNO R4 Wi-Fi BLE (Bluetooth Low Energy) board, which facilitates experiments with a new control approach for LEDs’ correlated color temperature (CCT). Together with the aforementioned platform, the methodology for mEDI calculation using an 11-channel multi-spectral sensor is presented. With proper calibration of the sensor, the visible spectrum can be reconstructed with a resolution of 1 nm, making the estimation of mEDI more accurate.


  • Open Access

    A Human-Centered Shelter Design for People on the Move in the Al-Sahel Region

    by Hind Al-Shoubaki, Dimitris Psychogyios, Matthias Drilling, Yioryos Chatziefthymiou, Tatiani Fragkou, André Marinho Costa, Aris Tsangrassoulis

    This article addresses the development of a human-centered shelter design tailored to meet the specific needs of refugees in the Al-Sahel Region. It focuses on five essential aspects of humanitarian-centered design. The goal is to create a livable unit that accommodates the three distinct phases of an emergency, transitional, and durable situation. We have adopted a non-linear design approach to develop the refugee shelter unit. We engage in discussions with team experts following each data collection phase. The conceptual design of the shelter unit is intended to align with the refugee settlement’s natural growth while maintaining a degree of control over its evolution. We have outlined a spatial configuration for a residential unit designed for three to six individuals and various patio options. Additionally, we have devised plans for an education and healthcare facility, all designed with the same structure to bring a more organized approach to the organic growth of the camp. The design proposal adopts a process-oriented approach, incorporating refugees indirectly in the design and construction of their shelters. While we do not assert that the framework of a ‘refugee camp’ can be sustainable, our goal is to show that its planning, in the absence of alternatives, should adhere to sustainability criteria.


  • Open Access

    The Future of Interior Lighting Is Here

    by Lambros T. Doulos, Aris Tsangrassoulis

    One word that characterizes the situation in the lighting industry during recent years is “change”


  • Open Access

    Assessment of Various Trombe Wall Geometries with CFD Study

    by Dimitrios Fidaros, Catherine Baxevanou, Michalina Markousi, Aris Tsangrassoulis

    An investigation of the optimal geometric configuration of a Trombe wall is presented with simulation of the transfer phenomena, that take place during its operation, using computational fluid dynamics. A numerical model is developed for a 2D steady-state simulation of a Trombe wall cross-section operation, and it is validated against an energy balance model’s results. Then the developed model is used for the evaluation of 10 different geometrical configurations examining various air gap widths, storage wall thicknesses, ventilation slots distances, and ventilation slots diameters. The examined geometries were evaluated with respect to the achieved temperature at the air gap exit and at the room facing storage wall surface, the achieved mass air flow in the air gap, and the ability of warm air stream from the gap to enter the test room. The aim was to ventilate the whole space without leaving large areas where the air just recirculates unaffected by the Trombe wall operation. According to the above-described criteria, optimum solution is an air gap width of 5 to 8 cm with increased distance between ventilation slots and a configuration of upper ventilation slot with an inclination of 30 degrees.


  • Open Access

    Analytical model for the simulation of Trombe wall operation with heat storage

    by Catherine Baxevanou, Dimitrios Fidaros, Aris Tsangrassoulis

    Passive solar systems, such as the Trombe wall, are cost-effective ways to reduce the energy consumption of buildings for heating, cooling, and ventilation. The operation of these systems can be simulated either with Building Energy Simulation Tools—BES like TRNSYS, EnergyPlus, etc either with Computational Fluid Dynamics—CFD. In both cases, the purchase of special software and/or special programming skills are required. In parallel analytical calculating tools are being developed, which also require some programming to solve an implicit system of non-linear equations but with fewer software requirements. The majority of analytical models concerns energy balance models for steady-state conditions with the result that heat storage is not taken into account, which in the case of a Trombe wall has a significant effect on the developed transport phenomena. In the present work, an analytical energy balance implicit model was developed for the simulation of the transient operation of a Trombe wall taking into account the heat storage. Using this model, the operation of a Trombe wall for 7 typical days of the year was simulated. The results are presented in terms of the daily evolution of the temperature with which the air enters the room served by the passive system, of the temperature of the Trombe wall surface adjacent to the served room, and of the airflow rate inside the air gap. These results are compared with the results that a system without heat storage would give. Both systems are assessed based on annual performance as calculated by a quasi-steady explicit model. The developed model can be used to calculate the operation of a Trombe wall as well as to supply explicit quasi-steady models with values for airflow rate inside the air gap for Trombe wall operation without mechanical ventilation. Feeding these values to a quasi-steady model developed by authors it was found that the increase of storage wall heat capacity, either changing the storage wall material, either using phase change materials, can offer better utilization of Trombe wall heat gains up to 35% yearly. Background: The present work aims to develop an analytical model for simulating the operation of a Trombe wall in a transient state taking into account the heat storage in the wall. Methods: A closed system of equations is developed, based on 5 energy balances and a series of assumptions and auxiliary relations, to calculate the operation of a wall Trombe with heat storage with an hourly time step. Results: Characteristics Trombe wall temperatures and mass flow rate through the air gap are calculated for typical days of 7 winter months. These are used for the calculation of utilizable heat gains from Trombe wall. Conclusions: The model that does not take into account heat storage predicts higher temperatures and air mass flow rate in the gap than the present model by 10%. However heat storage increase the utilizable heat gains by 35% compared with a system without heat storage.


  • Open Access

    Simulating the Impact of Daytime Calibration in the Behavior of a Closed Loop Proportional Lighting Control System

    by Aris Tsangrassoulis, Lambros Doulos, Angelos Mylonas

    A daylighting control system that uses the closed loop proportional algorithm needs to be calibrated both during nighttime and daytime. The selection of the daytime calibration time can affect the behavior of the system and is usually performed when the ratio of the illuminance of the ceiling sensor (SD,tc) to the illuminance at a point on the working plane (ED,tc) is relatively large without sunlight patches in the ceiling photo-sensor’s field of view (FOV). However, this requirement is not associated with a specific value and can be achieved under a wide range of conditions related to the sky luminance distribution. In the present work, four ceiling sensors with different field of views (FOVs) were examined in a typical north-facing office space. The effect of daytime calibration on the system’s performance was estimated through the calculation of lighting energy savings and the overdimming percentage. The results show that the effect of both the FOV of the ceiling sensor and the daytime calibration period is small except for the case of the sensor without cover, especially when it is close to the opening. In an attempt to quantify the SDtc/IDtc ratio, a new magnitude (RR) is proposed by dividing the illuminance ratios of the ceiling photo-sensor by that on the working surface during daytime and nighttime calibration. Thus, the daily calibration of the sensors with cover can be performed when RR > 1.


  • Open Access

    Daylight in Buildings and Visual Comfort Evaluation: the Advantages and Limitations

    by Amir Tabadkani, Astrid Roetzel, Hong Xian Li, Aris Tsangrassoulis

    Exposure to daylight significantly affects the psychological well-being of occupants by diminishing headaches, eye tensions, or stress. Daylight penetration is a matter of collaboration between building façade and perimeter zones that can be controlled through façade design features. This study reviews available daylighting systems to block or redirect natural light inside the space and their overall performance. Adaptation found to be the main key feature of daylighting systems to improve their effectiveness in indoor environments. As the main implication of such systems on the visual comfort performance of occupants, a list of quantitative indices is studied based on their mathematical equation to outline their advantages and limitations. Findings revealed a lack of agreement on acceptable indoor illuminance thresholds for most of the indices and the absence of a reliable glare index in presence of sun within the view field of the occupant. Similarly, many green building certifications propose a specific criterion to assess view out but remained a challenge for future studies.


  • Open Access

    Examining the Impact of Daylighting and the Corresponding Lighting Controls to the Users of Office Buildings

    by Lambros T. Doulos, Aris Tsangrassoulis, Evangelos-Nikolaos Madias, Spyros Niavis, Antonios Kontadakis, Panagiotis A. Kontaxis, Vassiliki T. Kontargyri, Katerina Skalkou, Frangiskos Topalis, Evangelos Manolis, et al.

    Daylight utilization significantly contributes to energy savings in office buildings. However, daylight integration requires careful design so as to include variations in daylight availability and maintain a balance between factors such as lighting quality and heat gain or loss. Designers with proper planning can not only improve the visual environment and create higher-quality spaces, but simultaneously minimize energy costs for buildings. The utilization of photosensors can exploit the benefits of daylighting by dimming the lighting system, so that no excessive luminous flux is produced, thus leading to energy savings as well as visual contentment. However, the human factor is crucial for the proper function of a lighting control system. Without its acceptance from the users, energy savings can be minimized or even negligible. The objective of this paper is to present a post-occupancy evaluation regarding occupant satisfaction and acceptance in relation to daylighting in offices equipped with automated daylight controls. In addition, the response of the users was compared with lighting measurements that were performed during the post-occupancy evaluation. Three case studies of office buildings with installed daylight-harvesting systems were examined. The age of the occupants was a crucial factor concerning their satisfaction in relation to the lighting levels. Aged users were more comfortable with lighting levels over 500lx, while young users were satisfied with 300lx. The impact of different control algorithms was outlined, with the integral reset algorithm performing poorly. The acceptance of the users for the closed loop systems maintained the expected energy savings of the daylight harvesting technique. Most of the occupants preferred to use daylight as a light source combined with artificial light but having the control to either override or switch it on and off at will. The results shown that a post-occupancy survey along with lighting measurements are significant for making an office environment a humancentric one.


  • Open Access

    Revision of Threshold Luminance Levels in Tunnels Aiming to Minimize Energy Consumption at No Cost: Methodology and Case Studies

    by Lambros T. Doulos, Ioannis Sioutis, Aris Tsangrassoulis, Laurent Canale, Kostantinos Faidas

    Because of the absence of lighting calculation tools at the initial stage of tunnel design, the lighting systems are usually over-dimensioned, leading to over illumination and increased energy consumption. For this reason, a fine-tuning method for switching lighting stages according to the traffic weighted L20 luminance is proposed at no additional cost. The method was applied in a real –case scenario, where L20 luminance of the access zone at eleven (11) existing tunnels was calculated. The traffic weighted method of CR14380 was used in order to calculate the actual luminance levels for the entrance zone. The new transition zone, which decreases luminance curves, was produced and compared with the existing ones. Thus, a new switching control was proposed and programed for the Supervisory Control and Data Acquisition (SCADA) system of the tunnel. The signals of the corresponding eleven L20 meters for a period of eight days were used and the corresponding annual energy consumptions were calculated using the proposed switching program for each tunnel. The results were compared with a number of scenarios in which the existing lighting system was retrofitted with Lighting Emitting Diodes (LED) luminaires. In these scenarios, the new luminaire arrangement was based not only on the existing luminance demand value for the threshold zone, but also on the newly proposed one with two different control techniques (continuous dimming and 10% step dimming). The fine-tuning method for switching resulted in energy savings between 11% and 54% depending on the tunnel when the scenario of the existing installation at no extra cost was used. Energy savings, when LED luminaires were installed, varied between 57% (for the scenario with existing luminance demand value for the threshold zone and 10% step dimming) and 85% (for the scenario with the new calculated luminance demand and continuous dimming).


  • Solar Lighting

    by Aris Tsangrassoulis