  • Self-contained image mapping of placental vasculature in 3D ultrasound-guided fetoscopy

    by Liangjing Yang, Junchen Wang, Takehiro Ando, Akihiro Kubota, Hiromasa Yamashita, Ichiro Sakuma, Toshio Chiba, Etsuko Kobayashi

    Surgical navigation technology directed at fetoscopic procedures is relatively underdeveloped compared with other forms of endoscopy. The narrow fetoscopic field of views and the vast vascular network on the placenta make examination and photocoagulation treatment of twin-to-twin transfusion syndrome challenging. Though ultrasonography is used for intraoperative guidance, its navigational ability is not fully exploited. This work aims to integrate 3D ultrasound imaging and endoscopic vision seamlessly for placental vasculature mapping through a self-contained framework without external navigational devices. This is achieved through development, integration, and experimentation of novel navigational modules. Firstly, a framework design that addresses the current limitations based on identified gaps is conceptualized. Secondly, integration of navigational modules including (1) ultrasound-based localization, (2) image alignment, and (3) vision-based tracking to update the scene texture map is implemented. This updated texture map is projected to an ultrasound-constructed 3D model for photorealistic texturing of the 3D scene creating a panoramic view of the moving fetoscope. In addition, a collaborative scheme for the integration of the modular workflow system is proposed to schedule updates in a systematic fashion. Finally, experiments are carried out to evaluate each modular variation and an integrated collaborative scheme of the framework. The modules and the collaborative scheme are evaluated through a series of phantom experiments with controlled trajectories for repeatability. The collaborative framework demonstrated the best accuracy (5.2 % RMS error) compared with all the three single-module variations during the experiment. Validation on an ex vivo monkey placenta shows visual continuity of the freehand fetoscopic panorama. The proposed developed collaborative framework and the evaluation study of the framework variations provide analytical insights for effective integration of ultrasonography and endoscopy. This contributes to the development of navigation techniques in fetoscopic procedures and can potentially be extended to other applications in intraoperative imaging.


  • Simultaneous evaluation of wall motion and blood perfusion of a beating heart using stereoscopic fluorescence camera system

    by Takehiro Ando, Hongho Kim, Etsuko Kobayashi, Hiroyuki Tsukihara, Noboru Motomura, Shunei Kyo, Minoru Ono, Ichiro Sakuma


  • Direct minimally invasive intraoperative electrophysiological mapping of the heart

    by Takehiro Ando, Dai Kawashima, Hongho Kim, Sanghyun Joung, Hongen Liao, Etsuko Kobayashi, Satoshi Gojo, Syunei Kyo, Minoru Ono, Ichiro Sakuma

    Introduction: Cardiac electrophysiology aims to describe and treat the electrical activity of the heart. Although an epicardial approach is valuable in many surgical treatments such as coronary artery bypass grafting, maze ablation, and cell transplantation, very few techniques suited for minimally invasive surgery are available for measurement of epicardial electrophysiology. Material and methods: We developed a novel endoscopically-deployable expanding electrode array that can be applied for minimally invasive surgery. Our device consists of a flexible electrode array attached to arms which open and close the electrode sheet. Furthermore, we also developed a computer program to overlay an epicardial electrophysiological map on an endoscopic image. We performed both laboratory and in vivo experiments to examine the feasibility in clinical situations. Results: Evaluation experiments demonstrated that our novel mapping process that assumes spherical deformation of the electrode array enables us to overlay each electrode position with an accuracy of < 1 mm. Results of animal experiments using large animals (one dog and two pigs) demonstrated that our system enables construction of epicardial electrophysiological maps. Conclusion: A novel endoscopically deployable expanding electrode array was developed. Evaluation experiments demonstrated that our device can be manipulated in simulated minimally invasive surgery, and enables construction of epicardial electrophysiological maps.

  • Precise comparison of protoporphyrin IX fluorescence spectra with pathological results for brain tumor tissue identification

    by Takehiro Ando, Etsuko Kobayashi, Hongen Liao, Takashi Maruyama, Yoshihiro Muragaki, Hiroshi Iseki, Osami Kubo, Ichiro Sakuma

    Photodynamic diagnosis is used during glioma surgery. Although some studies have shown that the spectrum of fluorescence was efficient for precise tumor diagnosis, previous methods to characterize the spectrum have been problematic, which can lead to misdiagnosis. In this paper, we introduce a comparison technique to characterize spectrum from pathology and results of preliminary measurement using human brain tissues. We developed a spectrum scanning system that enables spectra measurement of raw tissues. Because tissue preparations retain the shape of the device holder, spectra can be compared precisely with pathological examination. As a preliminary analysis, we measured 13 sample tissues from five patients with brain tumors. The technique enabled us to measure spectra and compare them with pathological results. Some tissues exhibited a good relationship between spectra and pathological results. Although there were some false positive and false negative cases, false positive tissue had different spectra in which intensity of short-wavelength side was also high. The proposed technique provides an accurate comparison of quantitative fluorescence spectra with pathological results. We found that spectrum analysis may reduce false positive errors. These results will increase the accuracy of tumor tissue identification.


  • High-sensitive fluorescence endoscope using electrocardiograph-synchronized multiple exposure

    by Takehiro Ando, Kazuhiro Taniguchi, Hongho Kim, Sanghyun Joung, Etsuko Kobayashi, Hongen Liao, Shunei Kyo, Ichiro Sakuma

    Fluorescence-based measurement of cardiac disease, using autofluorescent substances that already exist in the heart, has not been used for endoscopic surgery because the endoscopic lenses cannot transmit sufficient light. A highly sensitive fluorescence endoscope using an electrocardiograph (ECG)-synchronized multiple exposure (ESME) approach was developed that provides a bright fluorescent image. A system was developed consisting of an endoscope, an excitation light, an ECG amplifier, a trigger and delay unit, and a computer. This system is based on periodic motion of the heart. Since the shape of the heart can be photographed by ECG triggering in a similar manner, a bright image can be synthesized by accumulating multiple trigger-captured images. Laboratory and in vivo experiments were performed to confirm the effectiveness of ESME. The experimental results revealed that the trigger unit generated the synchronization signals required to produce high-quality images of the heart depending on heart rate. The difference among trigger-captured images from the actual organ, which affects the quality of ESME images, was estimated at 0.65 mm from the calculated displacement of a marker on the heart. The results also revealed that a bright fluorescent image can be captured by ESME. A highly sensitive fluorescence endoscope using ESME was developed and successfully tested. The experimental results indicated that the method enabled high-quality image acquisition in a very low illumination environment. This system is effective for the observation of faint fluorescence in the heart and is useful for the intraoperative examination of the heart status.