Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maximilian Koch has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design-Dependent Electrophysiological Effects of Electrolysis Electrodes Used for Endodontic Disinfection

    by Reinhard Bauer, Johannes Ringel, Maximilian Koch, Matthias W. Laschke, Andreas Burkovski, Matthias Karl

    Electrochemical disinfection in dentistry using boron-doped diamond (BDD) electrodes bears the potential risk of disturbing vital functions. Applying different arrays of BDD electrodes and an electrotome as reference, it was the goal of this animal study to compare their effects on an electrocorticogram (ECoG) and electrocardiogram (ECG). Following the trepanation of teeth in rats, the electrodes and electrotome were applied in a randomized manner while recording ECoG and ECG. The recordings were classified according to an electrophysiological significance score based on involvement, extent of disruption and duration. The scores obtained were compared by means of ANOVA followed by Dunn’s multiple comparisons test (α = 0.05). Voltage type and electrode design had a significant influence on the detectable electrophysiological effects. The results seen with BDD electrodes ranged from no detectable electrophysiological effects to a pronounced effect. The application of the electrotome induced the most pronounced effects. Given that electrotomes are safe medical devices, despite evoking greater disturbance compared to BDD electrodes, regardless of their design, electrochemical disinfection may be considered a safe procedure.

  • Open Access

    Diamond as Insulation for Conductive Diamond—A Spotted Pattern Design for Miniaturized Disinfection Devices

    by Manuel Zulla, Vera Vierheilig, Maximilian Koch, Andreas Burkovski, Matthias Karl, Stefan Rosiwal

    Boron-doped diamond (BDD) electrodes are well known for the in situ production of strong oxidants. These antimicrobial agents are produced directly from water without the need of storage or stabilization. An in situ production of reactive oxygen species (ROS) used as antimicrobial agents has also been used in recently developed medical applications. Although BDD electrodes also produce ROS during water electrolysis, only a few medical applications have appeared in the literature to date. This is probably due to the difficulties in the miniaturization of BDD electrodes, while maintaining a stable and efficient electrolytic process in order to obtain a clinical applicability. In this attempt, a cannula-based electrode design was achieved by insulating the anodic diamond layer from a cathodic cannula, using a second layer of non-conducting diamond. The undoped diamond (UDD) layer was successfully grown in a spotted pattern, resulting in a perfectly insulated yet still functional BDD layer, which can operate as a miniaturized flow reactor for medical applications. The spotted pattern was achieved by introducing a partial copper layer on top of the BDD layer, which was subsequently removed after growing the undoped diamond layer via etching. The initial analytical observations showed promising results for further chemical and microbial investigations.


  • Open Access

    Electrochemical Disinfection of Root Canals Bears No Risk of Damaging Periapical Tissues in a Dog Model

    by Maximilian Koch, Elena Demmer, Victor Palarie, Andreas Burkovski, Matthias Karl

    Boron-doped diamond (BDD) electrodes have been advocated as a potential treatment alternative to the established methods for root canal disinfection. As healing of periapical tissue is important in this context, the associated risk of host tissue damage was to be evaluated. Following in vitro cell culture experiments (HeLa cells), root canal treatment was performed in an animal trial comparing BDD electrode application and the currently used rinsing media with respect to cell viability and host tissue damage. Statistical analyses comparing the size of radiolucency were based on Kruskal-Wallis and Nemenyi’s All Pairs tests (α = 0.05). The direct application of BDD electrodes had a time-dependent effect on cell viability comparable to H2O2, NaOCl, and CHX application. In contrast to the chemical treatment, the effect of BDD electrodes was transient. Conventionally treated teeth and teeth additionally treated with BDD electrodes did not significantly differ from each other with respect to the size of the periapical radiolucency as observed radiographically (vertical p = 0.998 and horizontal p = 0.878) and histologically (vertical p = 0.940 and horizontal p = 0.862). While showing greater disinfection efficiency, the application of BDD electrodes for the electrochemical disinfection of root canals does not have a greater risk of host tissue damage compared to the conventional treatment.

  • Open Access

    Preclinical Testing of Boron-Doped Diamond Electrodes for Root Canal Disinfection—A Series of Preliminary Studies

    by Maximilian Koch, Victor Palarie, Lisa Koch, Andreas Burkovski, Manuel Zulla, Stefan Rosiwal, Matthias Karl

    While numerous approaches have meanwhile been described, sufficient disinfection of root canals is still challenging, mostly due to limited access and the porous structure of dentin. Instead of using different rinsing solutions and activated irrigation, the electrolysis of saline using boron-doped diamond (BDD) electrodes thereby producing reactive oxygen species may be an alternative approach. In a first step, experiments using extracted human teeth incubated with multispecies bacterial biofilm were conducted. The charge quantities required for electrochemical disinfection of root canals were determined, which were subsequently applied in an animal trial using an intraoral canine model. It could be shown that also under realistic clinical conditions, predictable disinfection of root canals could be achieved using BDD electrodes. The parameters required are in the range of 5.5 to 7.0 V and 9 to 38 mA, applied for 2.5 to 6.0 min with approximately 5 to 8 mL of saline. The direct generation of disinfective agents inside the root canal seems to be advantageous especially in situations with compromised access and limited canal sizes. The biologic effect with respect to the host reaction on BDD-mediated disinfection is yet to be examined.


  • Open Access

    Root Canal Obturation by Electrochemical Precipitation of Calcium Phosphates

    by Maximilian Koch, Victor Palarie, Maximilian Göltz, Marvin Kurzer, Manuel Zulla, Stefan Rosiwal, Marian Willner, Andreas Burkovski, Matthias Karl

    Achieving adequate disinfection and preventing reinfection is the major goal in endodontic treatment. Variation in canal morphology and open porosity of dentine prevents achieving complete disinfection. Questionable biocompatibility of materials as well as a lack of sealing ability questions the usefulness of current obturation methods. With a novel disinfection approach based on the use of boron-doped diamond (BDD) electrodes having shown promising results it was the goal of this series of experiments to investigate the possibility of BDD-mediated in situ forming of a biocompatible obturation material. A combination of calcium phosphate and maleic acid was used as precursor solution while Ion Chromatography Mass Spectrometry (IC-MS), Raman spectroscopy (RAMAN), X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), dye penetration and micro-computed tomography (µCT) were applied for characterizing the precipitate. It was possible to achieve a BDD-mediated precipitation of brushite in a clinically applicable timeframe. However, tight sealing of the canal system based on brushite could not be achieved.


  • Open Access

    Pilot Study on the Use of a Laser-Structured Double Diamond Electrode (DDE) for Biofilm Removal from Dental Implant Surfaces

    by Maximilian Koch, Andreas Burkovski, Manuel Zulla, Stefan Rosiwal, Walter Geißdörfer, Roman Dittmar, Tanja Grobecker-Karl

    No proper treatment option for peri-implantitis exists yet. Based on previous studies showing the in vitro effectiveness of electrochemical disinfection using boron-doped diamond electrodes, novel double diamond electrodes (DDE) were tested here. Using a ceramic carrier and a laser structuring process, a clinically applicable electrode array was manufactured. Roughened metal discs (n = 24) made from Ti-Zr alloy were exposed to the oral cavities of six volunteers for 24 h in order to generate biofilm. Then, biofilm removal was carried out either using plastic curettes and chlorhexidine digluconate or electrochemical disinfection. In addition, dental implants were contaminated with ex vivo multispecies biofilm and disinfected using DDE treatment. Bacterial growth and the formation of biofilm polymer were determined as outcome measures. Chemo-mechanical treatment could not eliminate bacteria from roughened surfaces, while in most cases, a massive reduction of bacteria and biofilm polymer was observed following DDE treatment. Electrochemical disinfection was charge- and time-dependent and could also not reach complete disinfection in all instances. Implant threads had no negative effect on DDE treatment. Bacteria exhibit varying resistance to electrochemical disinfection with Bacillus subtilis, Neisseria sp., Rothiamucilaginosa, Staphylococcus haemolyticus, and Streptococcus mitis surviving 5 min of DDE application at 6 V. Electrochemical disinfection is promising but requires further optimization with respect to charge quantity and application time in order to achieve disinfection without harming host tissue.


  • Open Access

    Electrochemical Disinfection of Dental Implants Experimentally Contaminated with Microorganisms as a Model for Periimplantitis

    by Maximilian Koch, Maximilian Göltz, Meng Xiangjun, Matthias Karl, Stefan Rosiwal, Andreas Burkovski

    Despite several methods having been described for disinfecting implants affected by periimplantitis, none of these are universally effective and may even alter surfaces and mechanical properties of implants. Boron-doped diamond (BDD) electrodes were fabricated from niobium wires and assembled as a single instrument for implant cleaning. Chemo-mechanical debridement and air abrasion were used as control methods. Different mono-species biofilms, formed by bacteria and yeasts, were allowed to develop in rich medium at 37 °C for three days. In addition, natural multi-species biofilms were treated. Implants were placed in silicone, polyurethane foam and bovine ribs for simulating different clinical conditions. Following treatment, the implants were rolled on blood agar plates, which were subsequently incubated at 37 °C and microbial growth was analyzed. Complete electrochemical disinfection of implant surfaces was achieved with a maximum treatment time of 20 min for Candida albicans, Candida dubliniensis, Enterococcus faecalis, Roseomonas mucosa, Staphylococcus epidermidis and Streptococcus sanguinis, while in case of spore-forming Bacillus pumilus and Bacillus subtilis, a number of colonies appeared after BDD electrode treatment indicating an incomplete disinfection. Independent of the species tested, complete disinfection was never achieved when conventional techniques were used. During treatment with BDD electrodes, only minor changes in temperature and pH value were observed. The instrument used here requires optimization so that higher charge quantities can be applied in shorter treatment times.


  • Open Access

    Influence of In-Situ Electrochemical Oxidation on Implant Surface and Colonizing Microorganisms Evaluated by Scanning Electron Microscopy

    by Maximilian Göltz, Maximilian Koch, Rainer Detsch, Matthias Karl, Andreas Burkovski, Stefan Rosiwal

    Peri-implantitis is a worldwide increasing health problem, caused by infection of tissue and bone around an implant by biofilm-forming microorganisms. Effects of peri-implantitis treatment using mechanical debridement, air particle abrasion and electrochemical disinfection on implant surface integrity were compared. Dental implants covered with bacterial biofilm were cleaned using mechanical debridement and air particle abrasion. In addition, implants were disinfected using a novel electrochemical technique based on an array of boron-doped diamond (BDD) coated electrodes. Following treatment and preparation, the implants were inspected by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). Mechanical debridement led to changes in surface topography destroying the manufacturer’s medium-rough surface by scratch formation. Air particle abrasion led to accumulation of the abrasive used on the implant surface. With both treatment options, appearance of bacteria and yeasts was not affected. In contrast, electrochemical disinfection did not cause alterations of the implant surface but resulted in distorted microbial cells. Electrochemical disinfection of implant surfaces using BDD electrodes may constitute a promising treatment option for cleaning dental implant surfaces without negatively affecting materials and surface properties.


  • Open Access

    Electrochemical Disinfection of Experimentally Infected Teeth by Boron-Doped Diamond Electrode Treatment

    by Anna-Lena Böhm, Maximilian Koch, Stefan Rosiwal, Andreas Burkovski, Matthias Karl, Tanja Grobecker-Karl

    Disinfection and prevention of re-infection are the decisive treatment steps in endodontic therapy. In this study, boron-doped diamond (BDD) electrodes have been fabricated and used for disinfecting the root canals of extracted human teeth, which had been covered with bacterial biofilms formed by Bacillus subtilis and Staphylococcus epidermidis. The growth of B. subtilis could be successfully impaired, achieving a complete disinfection after 8.5 min treatment time with the success of disinfection depending on the insertion depth of the electrode in the root canal. S. epidermidis could completely be removed after 3.5 min treatment time. A clinically applicable electrode array led to complete disinfection after treatment times of 10 min for S. epidermidis and 25 min for B. subtilis. BDD electrode application allowed for the improved disinfection of root canals and dentin tubules based on a continuous production of reactive oxygen species and their enhanced penetration of dentin tubules most likely due the formation of a continuous stream of small gas bubbles. The treatment times that are required here will be shortened in clinical application, as mechanical shaping of the canal system would precede the disinfection process.