Yunzhi Cheng
Research Subjects
Research Interests
Yunzhi Cheng has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Lingling Fan
Department of Electrical Engineering, University of South Florida, Tampa, FL, USA
4 shared publications - Zhixin Miao
Department of Electrical Engineering, University of South Florida, Tampa, FL, USA
4 shared publications - Bikash Chandra Pal
Imperial College London
2 shared publications - Deepak Ramasubramanian
EPRI, Palo Alto, CA, USA
2 shared publications Jonathan Rose
ERCOT, Austin, TX, USA
2 shared publicationsNilesh Modi
AEMO, Brisbane, Australia
2 shared publications
Latest Publications
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 24 (1) , 26-38
Feedback and Oscillations: Constructing Feedback Systems for Root Cause Analysis of Oscillations in Power Grids
Dynamic phenomena linked to inverter-based resources (IBRs) have gained global attention. Several IBR-induced dynamics have caused bulk power system-connected wind or solar power plants to trip, and some have even led to widespread outages. In addition, many oscillations have been observed involving IBR power plants. In 2023, the IEEE Power & Energy Society (PES) IBR Subsynchronous Oscillations (SSO) task force published a journal article, “Real-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources,” in which 19 IBR oscillation events were examined for their causation. Earlier in 2020, another PES task force article, “Definition and Classification of Power System Stability-Revisited & Extended,” authored by prominent academics, introduced converter-driven stability as a new category of stability. The international power grid industry community also took action by publishing the CIGRE Green Book, Power System Dynamic Modelling and Analysis in Evolving Networks (led by Babak Badrzadeh and Zia Emin) in 2024. In August 2024, the Energy Systems Integration Group (ESIG) released a practical guide led by Nick Miller, “Diagnosis and Mitigation of Observed Oscillations in IBR-Dominant Power System: A Practical Guide.” The goal of the guide is to assist practicing engineers in making initial judgments and conducting detailed analyses about oscillations. When addressing the classification of stability and oscillations, the guide emphasizes a causality-based taxonomy for grouping, such as voltage control-induced oscillations, synchronization-induced oscillations, and frequency or active power control-induced oscillations.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 24 (1) , 26-38
Feedback and Oscillations: Constructing Feedback Systems for Root Cause Analysis of Oscillations in Power Grids
Dynamic phenomena linked to inverter-based resources (IBRs) have gained global attention. Several IBR-induced dynamics have caused bulk power system-connected wind or solar power plants to trip, and some have even led to widespread outages. In addition, many oscillations have been observed involving IBR power plants. In 2023, the IEEE Power & Energy Society (PES) IBR Subsynchronous Oscillations (SSO) task force published a journal article, “Real-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources,” in which 19 IBR oscillation events were examined for their causation. Earlier in 2020, another PES task force article, “Definition and Classification of Power System Stability-Revisited & Extended,” authored by prominent academics, introduced converter-driven stability as a new category of stability. The international power grid industry community also took action by publishing the CIGRE Green Book, Power System Dynamic Modelling and Analysis in Evolving Networks (led by Babak Badrzadeh and Zia Emin) in 2024. In August 2024, the Energy Systems Integration Group (ESIG) released a practical guide led by Nick Miller, “Diagnosis and Mitigation of Observed Oscillations in IBR-Dominant Power System: A Practical Guide.” The goal of the guide is to assist practicing engineers in making initial judgments and conducting detailed analyses about oscillations. When addressing the classification of stability and oscillations, the guide emphasizes a causality-based taxonomy for grouping, such as voltage control-induced oscillations, synchronization-induced oscillations, and frequency or active power control-induced oscillations.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 13, 583-594
Inverter-Based Resource Oscillation Source Locating via Passivity
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 13, 583-594
Open AccessInverter-Based Resource Oscillation Source Locating via Passivity
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 23 (5) , 56-67
Texas Loads Ride Toward Grid Stability: Voltage Ride Through of Large Power Electronic Loads
ERCOT, the independent system operator (ISO) for the Texas region, USA, continuously assesses the reliability of its grid. With the increase of large loads interconnecting to the electric grid, including large data centers and crypto mining centers, maintaining grid reliability can become more challenging depending on the size of the load, its geographical location, its ramping controls, and network conditions. Further, a load’s lack of voltage ride-through (VRT) capability or frequency ride-through (FRT) capability could degrade system reliability. Additionally, these loads could introduce new vulnerabilities to sub-synchronous oscillations (SSO) or sub-synchronous control interactions (SSCI). This article will review realistic critical scenarios that require planning or operation level studies to assess reliability. These assessments will consider VRT and FRT tests with updated models, evaluations of large load on regions with known stability constraints, system impact of co-located load with generation, SSO/SSCI vulnerabilities and other similar reliability challenges.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 23 (5) , 56-67
Texas Loads Ride Toward Grid Stability: Voltage Ride Through of Large Power Electronic Loads
ERCOT, the independent system operator (ISO) for the Texas region, USA, continuously assesses the reliability of its grid. With the increase of large loads interconnecting to the electric grid, including large data centers and crypto mining centers, maintaining grid reliability can become more challenging depending on the size of the load, its geographical location, its ramping controls, and network conditions. Further, a load’s lack of voltage ride-through (VRT) capability or frequency ride-through (FRT) capability could degrade system reliability. Additionally, these loads could introduce new vulnerabilities to sub-synchronous oscillations (SSO) or sub-synchronous control interactions (SSCI). This article will review realistic critical scenarios that require planning or operation level studies to assess reliability. These assessments will consider VRT and FRT tests with updated models, evaluations of large load on regions with known stability constraints, system impact of co-located load with generation, SSO/SSCI vulnerabilities and other similar reliability challenges.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 23 (4) , 40-52
Large-Scale EMT Model Examples for High-Share IBR Systems: Using Large-Scale EMT Models for Operations and Planning Power Systems With a High Share of IBRs [Feature]
The use of electromagnetic-transient (EMT) models to study the behavior of power systems with high share of inverter-based resource (IBR) systems has become increasingly vital to ensure power system security over the last decade. Multiple system operators (SO) around the world have developed large scale EMT models to capture the interactions between the grid and IBR systems and between multiple IBR systems themselves. Four different SO, from Australia, Denmark, Finland, and Texas, USA, present learnings and examples of their methodologies for creating, maintaining and using large scale EMT models to ensure ongoing system security across their respective networks.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 23 (4) , 40-52
Large-Scale EMT Model Examples for High-Share IBR Systems: Using Large-Scale EMT Models for Operations and Planning Power Systems With a High Share of IBRs [Feature]
The use of electromagnetic-transient (EMT) models to study the behavior of power systems with high share of inverter-based resource (IBR) systems has become increasingly vital to ensure power system security over the last decade. Multiple system operators (SO) around the world have developed large scale EMT models to capture the interactions between the grid and IBR systems and between multiple IBR systems themselves. Four different SO, from Australia, Denmark, Finland, and Texas, USA, present learnings and examples of their methodologies for creating, maintaining and using large scale EMT models to ensure ongoing system security across their respective networks.
- Top Cited Papers
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1997-2000
Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting
The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. This letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1997-2000
Top Cited PapersCritical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting
The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. This letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (1) , 244-255
Sustained Oscillations in Modern AC Distribution Systems With High DER Infiltration
Sustained oscillations persist without decay, impacting system stability and performance. Sustained oscillations in distribution systems exhibit unique mechanisms compared to those in transmission systems, yet research in this area of distribution systems is lacking. In distribution systems, these oscillations degrade power quality, jeopardizing stability and causing relay malfunctions and supply discontinuity. Understanding their mechanisms in modern distribution systems is crucial for their detection, classification, and localization. This paper provides a comprehensive review of sustained oscillations in modern distribution systems. Additionally, it discusses key methodologies for detecting and classifying sustained oscillations in transmission systems. Finally, it applies transmission system methodologies to real cases in Ontario's distribution system, shedding light on challenges and future directions.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (1) , 244-255
Sustained Oscillations in Modern AC Distribution Systems With High DER Infiltration
Sustained oscillations persist without decay, impacting system stability and performance. Sustained oscillations in distribution systems exhibit unique mechanisms compared to those in transmission systems, yet research in this area of distribution systems is lacking. In distribution systems, these oscillations degrade power quality, jeopardizing stability and causing relay malfunctions and supply discontinuity. Understanding their mechanisms in modern distribution systems is crucial for their detection, classification, and localization. This paper provides a comprehensive review of sustained oscillations in modern distribution systems. Additionally, it discusses key methodologies for detecting and classifying sustained oscillations in transmission systems. Finally, it applies transmission system methodologies to real cases in Ontario's distribution system, shedding light on challenges and future directions.
- 15 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (4) , 2863-2873
Real-World 20-Hz IBR Subsynchronous Oscillations: Signatures and Mechanism Analysis
This paper provides analyses of subsynchronous oscillations associated with solar photovoltaics (PVs) observed in real world. All have oscillation frequencies at approximately 20 Hz in voltage and current magnitudes. On the other hand, in phase voltage and current, the oscillations show very different signatures. Through constructing simplified linear models and conducting sensitivity analysis, we are able to associate dynamic phenomena with the underlying mechanism and speculate the possible causes of the 20-Hz oscillations. The analysis results have all been validated via simulation results from electromagnetic transient (EMT) test beds constructed in MATLAB/Simscape.
- 15 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (4) , 2863-2873
Real-World 20-Hz IBR Subsynchronous Oscillations: Signatures and Mechanism Analysis
This paper provides analyses of subsynchronous oscillations associated with solar photovoltaics (PVs) observed in real world. All have oscillation frequencies at approximately 20 Hz in voltage and current magnitudes. On the other hand, in phase voltage and current, the oscillations show very different signatures. Through constructing simplified linear models and conducting sensitivity analysis, we are able to associate dynamic phenomena with the underlying mechanism and speculate the possible causes of the 20-Hz oscillations. The analysis results have all been validated via simulation results from electromagnetic transient (EMT) test beds constructed in MATLAB/Simscape.
- Top Cited Papers
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (1) , 316-330
Real-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources
This paper presents a survey of real-world subsynchronous oscillation events associated with inverter-based resources (IBR) over the past decade. The focus is on those oscillations in the subsynchronous frequency range known to be influenced by power grid characteristics, e.g., series compensation or low system strength. A brief overview of the historical events is presented followed by detailed descriptions of a series of events. This paper also examines causation mechanisms and proposes future research directions to meet grid needs worldwide.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (1) , 316-330
Top Cited PapersReal-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources
This paper presents a survey of real-world subsynchronous oscillation events associated with inverter-based resources (IBR) over the past decade. The focus is on those oscillations in the subsynchronous frequency range known to be influenced by power grid characteristics, e.g., series compensation or low system strength. A brief overview of the historical events is presented followed by detailed descriptions of a series of events. This paper also examines causation mechanisms and proposes future research directions to meet grid needs worldwide.
- 6 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (6) , 2135-2144
A Series Capacitor Based Frequency Scan Method for SSR Studies
This paper presents a new series capacitor based frequency scan method to assess the Subsynchronous Resonance (SSR) risk including Induction Generator Effect (IGE) and Subsynchronous Control Interaction (SSCI). Most existing frequency scan methods are generator based and calculate the impedance as viewed from the neural bus of the study generator. In this paper, the generator based frequency scan method is discovered to be inadequate or inapplicable to deal with a cluster of inverter based generation resources under some circumstances. The proposed method scans the impedance as viewed from the series capacitor to assess the IGE/SSCI risk. With nearby inverter based generation resources modeled by their frequency dependent impedances, the proposed method is capable of assessing the IGE/SSCI risk for a cluster of inverter based generation resources. The Electro-Magnetic Transient (EMT) simulation was conducted to validate the proposed method. The proposed method also successfully demonstrates the non-linear impact of the number of in-service units on the SSCI performance for a cluster of inverter based generators.
- 6 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (6) , 2135-2144
A Series Capacitor Based Frequency Scan Method for SSR Studies
This paper presents a new series capacitor based frequency scan method to assess the Subsynchronous Resonance (SSR) risk including Induction Generator Effect (IGE) and Subsynchronous Control Interaction (SSCI). Most existing frequency scan methods are generator based and calculate the impedance as viewed from the neural bus of the study generator. In this paper, the generator based frequency scan method is discovered to be inadequate or inapplicable to deal with a cluster of inverter based generation resources under some circumstances. The proposed method scans the impedance as viewed from the series capacitor to assess the IGE/SSCI risk. With nearby inverter based generation resources modeled by their frequency dependent impedances, the proposed method is capable of assessing the IGE/SSCI risk for a cluster of inverter based generation resources. The Electro-Magnetic Transient (EMT) simulation was conducted to validate the proposed method. The proposed method also successfully demonstrates the non-linear impact of the number of in-service units on the SSCI performance for a cluster of inverter based generators.