SPSaurav Pramanik

Saurav Pramanik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Saurav Pramanik has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • On Analytical Estimation of Inductances in Equivalent Ladder Network Model of a Homogeneous Transformer Winding Using FRA Data

    by Tirlingi Madhava Rao, Saurav Pramanik, Sourav Mitra

    The determination of ladder-network model parameters for transformer winding holds paramount significance in validating the design constraints of the transformer winding, with a particular emphasis on facilitating thorough analysis of its impulse behaviour. As these parameters cannot be measured directly, the majority of studies documented in the literature rely on iterative optimization techniques for estimation, and as of now, no analytical solution has been reported and implemented. To address this concern, this paper introduces an analytical approach for estimating unknown self and mutual inductances in equivalent ladder-network model of a homogeneous transformer winding, employing frequency response measurement. For this purpose, the method derived necessary linear and non-linear equations of unknown inductances pertaining to the coupled ladder-network model of the winding. The solution is directly obtained utilizing essential peak and trough frequencies extracted from three measured admittance magnitude responses along with series and ground capacitances determined separately. The practicality of the method has been verified using experimental results on three different transformer windings including one with iron-core. For improved precision, the estimated inductance values were fine-tuned further using conventional optimization technique. Results indeed demonstrate the practicality as well as efficacy of the method.


  • Parametric Evaluation for Comprehensive Fault Analysis in an Isolated HV-LV Winding Assembly Using Composite Frequency Response

    by Sourav Mitra, Saurav Pramanik

    This paper presents new analytical expressions for equivalent inductance, total ground capacitance of individual HV and LV windings, and inter-winding capacitance within an isolated HV-LV winding assembly. These expressions directly link the parameters to the coefficients of five specific composite driving-point admittance functions, each tailored for specific terminal configuration within the assembly. A specific ratio of two coefficients from the fitted rational function for each measured magnitude response at the line-end of HV and LV windings directly yields the equivalent inductance of each winding. Similarly, three other specific ratios of two coefficients, extracted from fitted rational functions of three other measured responses (two from HV terminal and one from LV), yield three equations, solving which determines three capacitances (inter-winding and ground capacitances of HV and LV winding). More importantly, this method remains invariant for estimating these parameters of two windings both in healthy and fault-conditions. Changes in inductance or capacitance identify the faulty winding(s) and also assist in identifying the specific fault types. Experimental validation on a 33/11 kV winding assembly with core shows promising results for various faults viz. inter-turn shorting, disk-space variation, and radial deformation, demonstrating the method's accuracy in estimation and fault-analysis.


  • Parametric Evaluation to Determine Type and Severity of Mechanical Fault in Transformer Winding Using Frequency Response Measurement

    by Sourav Mitra, Saurav Pramanik

    In parametric fault analysis, acquiring accurate knowledge of winding parameters under fault-conditions is both crucial and inherently challenging. To address this challenge, this paper proposed a very simple and effective method to extract three important winding parameters viz. equivalent inductance, equivalent capacitance and total ground capacitance of transformer winding from its measured frequency response. This method analytically derived a unique correlation between these three winding parameters with the three pairs of numerator and denominator polynomial coefficients of two specific driving-point admittance functions of the winding. Thus, these parameters can be obtained simply by fitting the two measured driving-point admittance magnitude responses to their respective ‘s’-domain rational functions. This method eliminates the need for geometrical data, and unlike previous approaches, does not necessitate any specific arrangement on transformer winding during measurement. Earlier methodologies never estimated transformer winding equivalent and ground capacitances under fault-condition. Employing the proposed method for few successive measurements, one can easily determine the change in these three winding parameters and evaluate the fault type and severity. This paper also presented the experimental results on two actual 11kV and 33kV continuous-disk windings for various fault-conditions viz. disk-space variation, inter-turn shorting and radial-buckling of transformer winding.


  • Double-End Excitation of a Single Isolated Transformer Winding: An Improved Frequency Response Analysis for Fault Detection

    by Saurav Pramanik, Aravind Ganesh, V S B Chaitanya Duvvury

    Frequency Response Analysis (FRA) is a comparison based method and is useful to identify the mechanical fault in transformer winding only when the ‘healthy’ or ‘reference’ magnitude response is available. But, in practice, ‘healthy’ response may not be always available and the subsequent FRA measurement alone also cannot detect the fault. This is one serious limitation for conventional FRA method and the desired solution is still far away. To this effect, this paper presents an innovative way of measuring the frequency responses of transformer winding with two equal and opposite polarity sinusoidal excitations from two ends. For viability test, the present work is limited to fault-detection only in a single isolated uniformly-wound transformer winding followed by verification on an actual single-phase autotransformer. The two equal and opposite polarity excitations for such winding are likely to impose a virtual ground at the centre and hence the two admittances measured from the two source-ends are likely to be identical. Two admittances also get dissimilar for a fault in transformer winding and therefore the fault could be identified simply by measuring and comparing these two responses in absence of ‘healthy’ response. Pertinent simulation and experimental results are also included in the paper.


  • An Attempt to Identify the Faulty Phase in Three-Phase Transformer Windings Using an Advanced FRA Measurement Technique

    by V S B Chaitanya Duvvury, Saurav Pramanik

    Although FRA method is very popular and well-known for its accuracy in fault-detection in three-phase transformer, it has not become an adept so far in fault localization. Fault-localization in transformer winding is undoubtedly an important aspect in fault diagnosis and providing a solution to any extent for this problem would be certainly a worthwhile contribution. Towards this approach, even identifying the faulty winding could be a substantial contribution to enhance the diagnostic performance of FRA method. To this context, this paper presents an innovative FRA measurement technique to identify the faulty phase (whether the middle or either of the two outer phases) in ‘delta-connected’ HV windings. Proposed technique imposes an apparent ‘second-delta’ from the terminals together with the presence of original ‘delta’ inside and measures the two desired output current responses simultaneously for an excitation to the middle phase. A mere observation of symmetry or asymmetry between the two responses determines whether the fault exists in the middle phase or in any of the two outer phase windings. Proposed technique is first evaluated by the simulation results followed by experimental measurements on actual three-phase transformer windings. Results reported in this paper are also found very promising and encouraging.


  • Tank Current Measurement of Three-Phase Transformer: Its Resonance Behavior and Sensitivity to Detect Mechanical Faults

    by Saurav Pramanik, V. S. B. Chaitanya Duvvury, Subrat Sahoo

    A novel technique to improve the fault detection sensitivity in three-phase transformer using tank current method is reported. Tank current method was first published by the first-author in recent past for single isolated transformer winding. A fault in a single isolated transformer winding was uniquely identified employing the typical resonance behaviour of tank current, but for three-phase transformer, such implementation is yet to be explored. Present scope of the work is only for uniformly wound three-phase transformer windings. Implementing the tank current method for such three-phase transformer may not be so simple since the neighbouring windings, unlike for isolated winding, strongly influence the measurement of tank current. Therefore, this paper appropriately considers the effect of neighbouring windings in a three-phase transformer and investigates the resonance behaviour of its tank current to propose a promising innovative extension approach of the method. Experimental results on actual transformers are also presented for practical validation of the proposed method. Results imply that the tank current method is indeed very sensitive to identify the fault in actual transformer compared to the conventional neutral current method. Authors also believe that the method needs to be reinforced by field measurements on several transformers to ascertain its viability.


  • Open Access

    Interleaved winding and suppression of natural frequencies

    by Saurav Pramanik, Sana Anees, Lakshminarayana Satish

    Ideally, it is desirable to design and manufacture a transformer winding that can render all its internal resonances non‐excitable. This study examines the effectiveness of an interleaved winding in achieving this goal. While investigating its effectiveness, it led to the establishment of a much desired theoretical basis that reinforces the reasons put forward in the literature to explain internal insulation failures observed in interleaved windings used in extra high voltage (EHV) transformers. Numerical calculations along with experimental verification on actual transformer windings are presented. This study reveals that most of the natural frequencies that are normally non‐excitable in the line and neutral current responses of an interleaved winding have been rendered excitable in the disk‐to‐disk voltages, thus, providing favourable conditions for insulation overstress because of resonant overvoltages. Prevalence of such a condition is an inherent characteristic of interleaved windings.