ZSZelekha A. Seedat

Zelekha A. Seedat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zelekha A. Seedat has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optically-pumped magnetometer-MEG (OPM-MEG) can detect and map epileptiform activity in diagnostic and presurgical paediatric cohorts

    by Christine M. Embury, Zelekha A. Seedat, Kelly St. Pier, Caroline Scott, Tim M Tierney, Umesh Vivekananda, Friederike Moeller, Krishna Das, Gareth R Barnes, Prejaas K.B. Tewarie, et al.


  • Open Access

    Simultaneous whole-head electrophysiological recordings using EEG and OPM-MEG

    by Zelekha A. Seedat, Kelly St. Pier, Niall Holmes, Molly Rea, Layla Al-Hilaly, Tim M. Tierney, Rosemarie Pardington, Karen J. Mullinger, J. Helen Cross, Elena Boto, et al.

    Electroencephalography (EEG) and magnetoencephalography (MEG) non-invasively measure human brain electrophysiology. They differ in nature; MEG offers better performance (higher spatial precision) whilst EEG (a wearable platform) is more practical. They are also complementary, with studies showing that concurrent MEG/EEG provides advantages over either modality alone, and consequently clinical guidelines for MEG in epilepsy recommend simultaneous acquisition of EEG. In recent years, new instrumentation – optically pumped magnetometers (OPMs) – has had a significant impact on MEG, offering improved performance, lifespan compliance, and wearable sensors. Nevertheless, the ability to carry out simultaneous EEG/OPM-MEG remains critical. Here, we investigated whether simultaneous, wearable, whole-head EEG and OPM-MEG measurably degrades signal quality in either modality. We employed two tasks: a motor task known to modulate beta oscillations, and an eyes-open/eyes-closed task known to modulate alpha oscillations. In both, we characterised the performance of EEG alone, MEG alone, and concurrent EEG/OPM-MEG. Our results show that the SNR of the beta response was very similar, regardless of whether modalities were used individually or concurrently. Likewise, our alpha band recordings demonstrated that signal contrast was stable, regardless of the concurrent recording. These results combined suggest that there are no fundamental barriers to simultaneous wearable EEG/OPM-MEG, and consequently this technique is ripe for neuroscientific and clinical adoption. This will be particularly important in the clinical sphere where a direct comparison between simultaneous EEG and OPM-MEG recordings will facilitate interpretation of OPM-MEG data in patients.


  • Open Access

    Mapping Interictal activity in epilepsy using a hidden Markov model: A magnetoencephalography study

    by Zelekha A. Seedat, Lukas Rier, Lauren E. Gascoyne, Harry Cook, Mark W. Woolrich, Andrew J. Quinn, Timothy P. L. Roberts, Paul L. Furlong, Caren Armstrong, Kelly St. Pier, et al.

    Epilepsy is a highly heterogeneous neurological disorder with variable etiology, manifestation, and response to treatment. It is imperative that new models of epileptiform brain activity account for this variability, to identify individual needs and allow clinicians to curate personalized care. Here, we use a hidden Markov model (HMM) to create a unique statistical model of interictal brain activity for 10 pediatric patients. We use magnetoencephalography (MEG) data acquired as part of standard clinical care for patients at the Children's Hospital of Philadelphia. These data are routinely analyzed using excess kurtosis mapping (EKM); however, as cases become more complex (extreme multifocal and/or polymorphic activity), they become harder to interpret with EKM. We assessed the performance of the HMM against EKM for three patient groups, with increasingly complicated presentation. The difference in localization of epileptogenic foci for the two methods was 7 ± 2 mm (mean ± SD over all 10 patients); and 94% ± 13% of EKM temporal markers were matched by an HMM state visit. The HMM localizes epileptogenic areas (in agreement with EKM) and provides additional information about the relationship between those areas. A key advantage over current methods is that the HMM is a data‐driven model, so the output is tuned to each individual. Finally, the model output is intuitive, allowing a user (clinician) to review the result and manually select the HMM epileptiform state, offering multiple advantages over previous methods and allowing for broader implementation of MEG epileptiform analysis in surgical decision‐making for patients with intractable epilepsy.


  • Open Access

    Unpacking Transient Event Dynamics in Electrophysiological Power Spectra

    by Andrew J. Quinn, Freek van Ede, Matthew J. Brookes, Simone G. Heideman, Magdalena Nowak, Zelekha A. Seedat, Diego Vidaurre, Catharina Zich, Anna C. Nobre, Mark W. Woolrich

    Electrophysiological recordings of neuronal activity show spontaneous and task-dependent changes in their frequency-domain power spectra. These changes are conventionally interpreted as modulations in the amplitude of underlying oscillations. However, this overlooks the possibility of underlying transient spectral ‘bursts’ or events whose dynamics can map to changes in trial-average spectral power in numerous ways. Under this emerging perspective, a key challenge is to perform burst detection, i.e. to characterise single-trial transient spectral events, in a principled manner. Here, we describe how transient spectral events can be operationalised and estimated using Hidden Markov Models (HMMs). The HMM overcomes a number of the limitations of the standard amplitude-thresholding approach to burst detection; in that it is able to concurrently detect different types of bursts, each with distinct spectral content, without the need to predefine frequency bands of interest, and does so with less dependence on a priori threshold specification. We describe how the HMM can be used for burst detection and illustrate its benefits on simulated data. Finally, we apply this method to empirical data to detect multiple burst types in a task-MEG dataset, and illustrate how we can compute burst metrics, such as the task-evoked timecourse of burst duration.