Tianyuan Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tianyuan Tan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Jian Le
School of Electrical Engineering, Wuhan University, Wuhan, Hubei, China
1 shared publicationJian Liu
School of Electrical Engineering, Wuhan University, Wuhan, Hubei, China
1 shared publication- Junhua Wang
Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication - Junmin Zhang
Jiangsu Electric Power Co.,Ltd.,Suzhou,China
1 shared publication Kaipei Liu
School of Electrical Engineering, Wuhan University, Wuhan, Hubei, China
1 shared publication- Kaipei Liu
Department of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication
Latest Publications
- Open Access
- 13 June 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (6) , e0157057
Improved Active Harmonic Current Elimination Based on Voltage Detection
With the increasing penetration of power electronic equipment in modern residential distribution systems, harmonics mitigation through the distributed generation (DG) interfacing converters has received significant attention. Among recently proposed methods, the so-called active resonance damper (ARD) and harmonic voltage compensator (HVC) based on voltage detection can effectively reduce the harmonic distortions in selected areas of distribution systems. However, it is found out that when traditional ARD algorithm is used to eliminate harmonic current injected by non-linear loads, its performance is constrained by stability problems and can at most eliminate half of the load harmonic currents. Thus, inspired by the duality between ARD and HVC, this paper presents a novel improved resistive active power filter (R-APF) algorithm based on integral-decoupling control. The design guideline for its parameters is then investigated through carefully analyzing the closed-loop poles’ trajectory. Computer studies demonstrate that the proposed algorithm can effectively mitigate the load harmonic currents and its performance is much better than traditional ARD based on proportional control.
- 13 June 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (6) , e0157057
Open AccessImproved Active Harmonic Current Elimination Based on Voltage Detection
With the increasing penetration of power electronic equipment in modern residential distribution systems, harmonics mitigation through the distributed generation (DG) interfacing converters has received significant attention. Among recently proposed methods, the so-called active resonance damper (ARD) and harmonic voltage compensator (HVC) based on voltage detection can effectively reduce the harmonic distortions in selected areas of distribution systems. However, it is found out that when traditional ARD algorithm is used to eliminate harmonic current injected by non-linear loads, its performance is constrained by stability problems and can at most eliminate half of the load harmonic currents. Thus, inspired by the duality between ARD and HVC, this paper presents a novel improved resistive active power filter (R-APF) algorithm based on integral-decoupling control. The design guideline for its parameters is then investigated through carefully analyzing the closed-loop poles’ trajectory. Computer studies demonstrate that the proposed algorithm can effectively mitigate the load harmonic currents and its performance is much better than traditional ARD based on proportional control.
- Open Access
- 19 January 2016
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 4 (1) , 47-53
Harmonic analysis based on time domain mutual-multiplication window
- 19 January 2016
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 4 (1) , 47-53
Open AccessHarmonic analysis based on time domain mutual-multiplication window