Phillip Jannotti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Phillip Jannotti has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
J.T. Lloyd
2 shared publications- Arun K. Varshneya
Alfred University
1 shared publication Brian E. Schuster
U.S. Army Research Laboratory
1 shared publication- Brian Elias Schuster
The University of Texas at El Paso 1 Department of Metallurgical, Materials, and Biomedical Engineering El Paso, Texas 79968
1 shared publication - Christopher S. Meredith
DEVCOM Army Research Laboratory
1 shared publication - Daniel J. Magagnosc
DEVCOM Army Research Laboratory
1 shared publication
Latest Publications
- 26 October 2022
- Published by Defense Technical Information Center (DTIC)
Computer Vision Quantification of Complex Fracture
- 26 October 2022
- Published by Defense Technical Information Center (DTIC)
Computer Vision Quantification of Complex Fracture
- 1 October 2021
- Published by Elsevier in Mechanics of Materials
- Vol. 161
Pre-twinned magnesium for improved ballistic performance
- 1 October 2021
- Published by Elsevier in Mechanics of Materials
- Vol. 161
Pre-twinned magnesium for improved ballistic performance
- 1 September 2021
- Published by Elsevier in Mechanics of Materials
- Vol. 160
Role of anisotropy in the ballistic response of rolled magnesium
- 1 September 2021
- Published by Elsevier in Mechanics of Materials
- Vol. 160
Role of anisotropy in the ballistic response of rolled magnesium
- 21 November 2019
- Published by Springer Nature
- p. 189-195
Application of High-Speed Digital Image Correlation to Taylor Impact Testing
- 21 November 2019
- Published by Springer Nature
- p. 189-195
Application of High-Speed Digital Image Correlation to Taylor Impact Testing
- 31 October 2017
- Published by Springer Nature
- p. 155-161
Application of 3D Digital Image Correlation In Ballistic Testing
- 31 October 2017
- Published by Springer Nature
- p. 155-161
Application of 3D Digital Image Correlation In Ballistic Testing
- 15 October 2011
- Published by Wiley in International Journal of Applied Glass Science
- Vol. 2 (4) , 275-281
Photoelastic Measurement of High Stress Profiles in Ion‐Exchanged Glass
Photoelastic fringes were directly measured to fully characterize high magnitude, steep compressive stress gradients in an ion‐exchanged glass, trade named I on‐ A rmor™. Initially, using a thick (9.9 mm) rectangular bar and circular polariscope arrangement the overall residual stress profile in a bulk specimen was determined. However, due to the relatively large thickness of the specimen, the high density of fringes (steep stress gradient) close to the edge of the specimen became too diffused to allow an accurate count of fringe order. A thinner (0.71 mm) specimen was then used along with a polarizing light microscope to enhance the fringe contrast. This arrangement yielded approximately four isochromatic fringes, representing a maximum surface compressive stress of 984 MPa, which rapidly decreased to ~300 MPa within 25 μm depth from the strengthened surface. Also, the case‐depth of the ion‐exchange process was found to be 0.8 mm. Thus, the technique was able to directly capture the extremely high residual compressive stresses generated in an ion‐exchanged glass. The current technique utilized for residual stress measurement is more objective and straightforward to implement than what is specified in ASTM standard C ‐1422, particularly for those specimens having steep stress gradients just below the strengthened surface.
- 15 October 2011
- Published by Wiley in International Journal of Applied Glass Science
- Vol. 2 (4) , 275-281
Photoelastic Measurement of High Stress Profiles in Ion‐Exchanged Glass
Photoelastic fringes were directly measured to fully characterize high magnitude, steep compressive stress gradients in an ion‐exchanged glass, trade named I on‐ A rmor™. Initially, using a thick (9.9 mm) rectangular bar and circular polariscope arrangement the overall residual stress profile in a bulk specimen was determined. However, due to the relatively large thickness of the specimen, the high density of fringes (steep stress gradient) close to the edge of the specimen became too diffused to allow an accurate count of fringe order. A thinner (0.71 mm) specimen was then used along with a polarizing light microscope to enhance the fringe contrast. This arrangement yielded approximately four isochromatic fringes, representing a maximum surface compressive stress of 984 MPa, which rapidly decreased to ~300 MPa within 25 μm depth from the strengthened surface. Also, the case‐depth of the ion‐exchange process was found to be 0.8 mm. Thus, the technique was able to directly capture the extremely high residual compressive stresses generated in an ion‐exchanged glass. The current technique utilized for residual stress measurement is more objective and straightforward to implement than what is specified in ASTM standard C ‐1422, particularly for those specimens having steep stress gradients just below the strengthened surface.