Piyush Kumar Sinha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Piyush Kumar Sinha has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Kishore Gurumoorthy Subramanya Bharathy
Department of Surgical Gastroenterology, Institute of Digestive and HPB Sciences, Sakra World Hospital, Bengaluru, Karnataka, India
2 shared publications - Shridhar Vasantrao Sasturkar
Institute of Liver and Biliary Sciences
2 shared publications - Viniyendra Pamecha
Department of Hepato-Pancreato-Biliary and Liver Transplant Surgery, Institute of Liver and Biliary Sciences, New Delhi, India
2 shared publications - Nihar Mohapatra
Institute of Liver and Biliary Sciences
1 shared publication - Senthil Kumar
Department of HPB Surgery and Liver Transplantation, Institute of Liver & Biliary Sciences, New Delhi, India
1 shared publication - Shiv Kumar Sarin
Department of Hepatology, Institute of Liver and Biliary Sciences, New Delhi, India
1 shared publication
Latest Publications
- Open Access
- 31 October 2024
- Published by MDPI AG in Transplantology
- Vol. 5 (4) , 258-262
Splenectomy Before Recipient Hepatectomy for Inflow Modulation Using a Very Small Modified Right Hemiliver Graft: A Case Report
Portal inflow modulation has become standard practice in many transplant centers performing living donor liver transplantation. This is believed to counteract the deleterious effects of excess portal flow into a small-for-size graft. A splenectomy negates the contribution of the splenic vein flow completely and thereby substantially reduces portal inflow. Although it has been adopted as a standard strategy by many Japanese centers for inflow modulation, especially while using left hemiliver grafts, there is justifiable apprehension about its usage due to potential increases in morbidity. Described here is a splenectomy performed while using a modified right hemiliver graft with a graft to recipient weight ratio of 0.49. The challenges in decision making and reasons regarding how such a small graft might have worked without manifestations of small-for-size/flow syndrome are discussed.
- 31 October 2024
- Published by MDPI AG in Transplantology
- Vol. 5 (4) , 258-262
Open AccessSplenectomy Before Recipient Hepatectomy for Inflow Modulation Using a Very Small Modified Right Hemiliver Graft: A Case Report
Portal inflow modulation has become standard practice in many transplant centers performing living donor liver transplantation. This is believed to counteract the deleterious effects of excess portal flow into a small-for-size graft. A splenectomy negates the contribution of the splenic vein flow completely and thereby substantially reduces portal inflow. Although it has been adopted as a standard strategy by many Japanese centers for inflow modulation, especially while using left hemiliver grafts, there is justifiable apprehension about its usage due to potential increases in morbidity. Described here is a splenectomy performed while using a modified right hemiliver graft with a graft to recipient weight ratio of 0.49. The challenges in decision making and reasons regarding how such a small graft might have worked without manifestations of small-for-size/flow syndrome are discussed.
- 1 January 2020
- Published by Elsevier in Journal of Gastrointestinal Surgery
- Vol. 24 (8) , 1818-1826
Preoperative Alanine Aminotransferase and Remnant Liver Volume Predict Liver Regeneration After Live Donor Hepatectomy
- 1 January 2020
- Published by Elsevier in Journal of Gastrointestinal Surgery
- Vol. 24 (8) , 1818-1826
Preoperative Alanine Aminotransferase and Remnant Liver Volume Predict Liver Regeneration After Live Donor Hepatectomy
- 17 March 2016
- Published by Springer Nature in Hepatology International
- Vol. 10 (4) , 657-664
Selection and outcome of the potential live liver donor
Background and aim A thorough donor evaluation in the living donation process is mandatory to ensure a safe outcome in an otherwise healthy individual. The aim of the current study was to evaluate the reasons for not proceeding to donation and the outcome of live liver donors. Methods A prospective study of potential donors who underwent evaluation and proceeded to surgery from 1 April 2012 to 31 January 2015 was conducted. The process of donor selection, its outcome and peri-operative complications were recorded. Results A total of 460 donors were evaluated in a stepwise manner for 367 potential recipients. Of the 321 (69.7 %) donors not proceeding to donation, the reasons were donor-related in 63.6 % and recipient-related in the rest. Common donor-related reasons were: donor reluctance (23.5 %), negative liver attenuation index (16.2 %), anatomic variations (10.3 %), inadequate remnant liver volume (9.8 %), unacceptable liver biopsy (8.8 %), and inadequate graft volume (5.4 %). A majority of donors (82.8 %) were turned down early in the (steps 1 and 2) evaluation process. Recipient death was the most common recipient-related reason [n = 51 (43.6 %)] for not proceeding to donation. There was no donor mortality. The overall complication rate was 19.8 % and major complication rate (grade 3 or higher) was 4.4 %. Conclusions A stringent stepwise donor evaluation process leads to early recognition of unsuitable donors and a low complication rate.
- 17 March 2016
- Published by Springer Nature in Hepatology International
- Vol. 10 (4) , 657-664
Selection and outcome of the potential live liver donor
Background and aim A thorough donor evaluation in the living donation process is mandatory to ensure a safe outcome in an otherwise healthy individual. The aim of the current study was to evaluate the reasons for not proceeding to donation and the outcome of live liver donors. Methods A prospective study of potential donors who underwent evaluation and proceeded to surgery from 1 April 2012 to 31 January 2015 was conducted. The process of donor selection, its outcome and peri-operative complications were recorded. Results A total of 460 donors were evaluated in a stepwise manner for 367 potential recipients. Of the 321 (69.7 %) donors not proceeding to donation, the reasons were donor-related in 63.6 % and recipient-related in the rest. Common donor-related reasons were: donor reluctance (23.5 %), negative liver attenuation index (16.2 %), anatomic variations (10.3 %), inadequate remnant liver volume (9.8 %), unacceptable liver biopsy (8.8 %), and inadequate graft volume (5.4 %). A majority of donors (82.8 %) were turned down early in the (steps 1 and 2) evaluation process. Recipient death was the most common recipient-related reason [n = 51 (43.6 %)] for not proceeding to donation. There was no donor mortality. The overall complication rate was 19.8 % and major complication rate (grade 3 or higher) was 4.4 %. Conclusions A stringent stepwise donor evaluation process leads to early recognition of unsuitable donors and a low complication rate.