Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abdellatif M. Aboutaleb has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Jos Knockaert

    Research Group EELab/Lemcko, Department of Electromechanical, Systems and Metal Engineering, Faculty of Engineering and Architecture, Ghent University, 8500 Kortrijk, Belgium

    6 shared publications
  • Jan Desmet

    Department of Electromechanical, Systems and Metal Engineering, Research Group EnSy/Lemcko, Ghent University, Kortrijk, Belgium

    4 shared publications
  • Dina S. M. Osheba

    Department of Electrical Engineering, Minoufiya University, Shebin El-Kom, Egypt

    3 shared publications
  • Marwa S. Osheba

    Research Group EELab/Lemcko, Department of Electromechanical, Systems and Metal Engineering, Faculty of Engineering and Architecture, Ghent University, 8500 Kortrijk, Belgium

    3 shared publications
  • Awad E. El-Sabbe

    Department of Electrical Engineering, Minoufiya University, Shebin El-Kom, Egypt

    2 shared publications
  • Haitham Z. Azazi

    Department of Electrical Engineering, College of Engineering, King Khalid University, Abha, Saudi Arabia

    2 shared publications

Latest Publications

  • LED Lamp Flicker Assessment Under Distorted Grid Voltage in Both Harmonic and Supraharmonic Ranges

    by Marwa S. Osheba, Abdellatif M. Aboutaleb, Jan Desmet, Jos Knockaert

    Supraharmonic (SH) background distortions are blamed for light flickers produced from LED lamps with no clear evidence in literature. Consequently, this article is structured to investigate the effect of the background distortions in the harmonic and SH ranges on the light flickers produced from low power LED lamps that are widely used in residential applications. Four scenarios are performed: The first and second scenarios are done by exposing the LED lamp to a background distortion with harmonic and interharmonic voltage components, respectively. The third and fourth scenarios explore the impact of the grid voltage distortion in the SH range with frequencies that are integer and noninteger multiples of the grid frequency, respectively, on LED lamp flickers. The conducted study comes to the conclusion that visible flicker only appears for scenario 2, in which the visible flicker effect is in inverse relationship with the interharmonic frequencies. In both scenarios 1 and 3, no visible flicker is detected. In scenario 4, the light flicker is negligible. The observations are carried out experimentally on a commercial LED lamp. Then a mathematical analysis is provided to explain the observations in the four scenarios. The main outcomes are validated through a simulation study.


  • A Novel Active Power Filter for Supraharmonic Emissions of Single Phase Grid-Connected Inverters

    by Abdellatif M. Aboutaleb, Jan Desmet, Jos Knockaert

    Conventional active power filters (APFs) are not appropriate to reduce the emissions of grid connected converters in supraharmonic (SH) range due to many limitations. Consequently, this article presents a novel APF designed for reducing the SH emissions of single-phase grid-connected inverters (GCIs). The new design solves many obstacles that limit the usage of conventional APFs to filter out the SH emissions of GCIs as: The switching frequency of the proposed APF is same as the one used with the GCI, excluding the need for harmonic current calculation, a simple current controller is used based on a proportional resonance controller, multiple distributed filtering bandwidths are acquired, a simple design criteria for the APF power circuit is required, in addition to that, there is no need for higher ordered coupling passive filters for both GCI and APF. The proposed approach is also superior in its performance than its counterparts that are used to mitigate the SH emissions of GCIs. A mathematical analysis is performed to describe the GCI emissions in SH range and to give the basic principles of filtering. The performance of the proposed APF is verified through simulation and experimental studies.


  • Open Access

    Comparison of the Impacts of Background Distortion with Even and Odd Orders in the Supraharmonic Range on Grid-Connected Converters

    by Abdellatif M. Aboutaleb, Marwa S. Osheba, Jan Desmet, Jos Knockaert

    In this paper, a comparison of the emissions of grid-connected converters under grid distortion in the supraharmonic range is performed. The investigated supraharmonic grid distortion is divided into two types, namely odd-integer and even-integer multiples of the grid frequency. It is found that the first distortion type does not affect the emissions of the grid-connected converters, while the second distortion is responsible for the 2N-harmonic emissions that appear in the frequency spectra of the grid-connected converters, which, in turn, interact with the supraharmonic primary emissions of these converters, resulting in additional supraharmonic emissions. To explain this behavior, a mathematical analysis is provided for two types of grid-connected converters with an inverter interface and with a diode bridge rectifier interface. Simulations and experimental studies are performed to verify the main findings of the mathematical analysis.


  • Open Access

    The Impact of Grid Distortion on the Power Conversion Harmonics of AC/DC Converters in the Supraharmonic Range

    by Marwa S. Osheba, Abdellatif M. Aboutaleb, Jan Desmet, Jos Knockaert

    AC/DC converters, controlled by pulse width modulation (PWM) and used as power factor correction (PFC), is considered one of the main contributors to emissions in the range 2 kHz–150 kHz, recently known as the supraharmonic (SH) range. This study looks at the impact of SH grid distortion on the LF (2 kHz) emission of an AC/DC converter. The PFC boost converter is used as a particular case for validation of the results. It is observed that the AC/DC converters emit additional LF interharmonics and subharmonics when the grid voltage contains interharmonic components in the SH range. A mathematical analysis is provided to study and assess the interference between the SH in the background distortion and the AC/DC converters. Experimental studies are then performed for a PFC boost setup based on dSPACE MicroLabBox for the purposes of validating the mathematical analysis.


  • Self-Induced and Mutual-Induced Emissions of Grid-Tied Converters

    by Abdellatif M. Aboutaleb, Amin Gholizad, Jan Desmet, Jos Knockaert

    The increased use of grid-tied converters (GTCs) leads to power conversion harmonics in low voltage networks in supraharmonics range. The effect of using grid-tied converters with switching rates that are non-integer multiples of the grid frequency is studied. It is observed that both high frequency (HF) and low frequency (LF) emissions increase more than what is expected and occur at many interharmonic frequencies, due to a combination of feedback mechanisms. When a GTC is switched with a non-integer multiple of the grid frequency, extra harmonic bands appear around the main LF and HF harmonics emitted from the GTC. The frequencies of these additional harmonics depend on the deviation of the HF emissions from the nearest integer multiple of the grid frequency. Two definitions are presented, the self-induced emissions which represent the extra high frequency emissions generated by the device itself, and the mutual-induced emissions which define the extra emissions of a device around its switching frequency and its multiples as a reflected effect of the high frequency emissions of a neighboring device. Simulations using MATLAB software are performed to clarify the results. An experimental setup is used to verify the outcomes with two case studies.


  • Open Access

    Impact of Grid-Connected Inverter Parameters on the Supraharmonic Emissions in Distributed Power Generation Systems

    by Abdellatif M. Aboutaleb, Jan Desmet, Jos Knockaert

    In this paper, a mathematical analysis is presented to show the effect of grid-connected inverter (GCI) parameters on its emissions in the supraharmonic range. This analysis is extended to explain the effect of asymmetry on the emissions of parallel-connected GCIs on distributed power generation systems. The switching harmonics of a GCI appear as bands around the switching frequency and its multiples. A MATLAB/Simulink model is built to perform two studies. In the first study, we use one GCI to examine the effect of the parameters on the emissions, while in the second study, we examine the effect of the asymmetry of two parallel-connected GCIs on the total emission toward the grid. An actual setup is built to verify the results of the mathematical analysis and the simulation study. It is found that the SHs of single-phase GCI amplitude are strongly dependent on the DC-link voltage and the coupling inductor, while the phases of the sideband harmonics only change with changing the injected power. The variation of the injected power does not have any tangible effect on the carrier harmonics.


  • Analysis of transmission line modelling in the MATLAB/Simscape software package

    by A.M. Aboutaleb, G.G. Roumeliotis, J. Desmet, J. Knockaert

    In this paper, the Bergeron model (BM) of the transmission line (TL) considering losses used in MATLAB/Simscape toolbox is studied and analysed for high frequency related studied including the supraharmonics range (2-150 kHz). The BM is preferred among other models for software since it can describe the lossless TLs in the time domain for all frequency ranges. However, it fails side by side with the lossy BM to calculate the impedance of the line especially close to the resonance regions. This in turn limits the usage of the simulation software for studying the SH. The analysis of this problem and a proposed solution are presented in this paper.


  • A shunt active filter for compensating harmonics and unbalance in three-phase four-wire systems

    by Abdellatif M. Aboutaleb, Haitham Z. Azazi, Dina S. M. Osheba, Awad E. El-Sabbe

    This paper introduces a split-capacitor shunt Active Power Filter (SC-APF) based on Synchronous Reference Frame (SRF) theory. This topology is used in compensating the currents of 3-Ph unbalanced non-linear loads. The voltage control loop used in SRF which is only suitable in controlling Four-Leg APF (FL-APF) is modified to control Spilt-Capacitor APF (SC-APF). The proposed scheme provides compensating the 3-Ph unbalanced non-linear loads with lower number of switches, passive elements, and sensors. The performance of the SC-APF with the modified calculation algorithm is verified through simulation and experimental studies.


  • A four-switch shunt active filter based on one cycle control for compensating non-linear loads

    by Abdellatif M. Aboutaleb, Haitham Z. Azazi, Dina S. M. Osheba, Awad E. El-Sabbe

    This paper introduces a Four-Switch Three-Phase Shunt Active Power Filter (FSTP-APF) based on One Cycle Control (OCC) technique for compensating the currents of three phase non-linear loads. The power stage of FSTP-APF uses only four semiconducting switches which leads to reduce the overall cost of APF. The proposed technique retains the advantages of the conventional OCC, such as no reference current calculation, no need for using Phase-Locked Loop (PLL), very simple control circuit and constant switching frequency. In addition, the modification reduces the number of semiconductor switches, reduces the filter output inductances, reducing the number of sensors to only four sensors, two of them for measuring supply currents and the others for measuring DC-link voltages, and the control algorithm becomes simpler. The feasibility and performance of the proposed technique are demonstrated through the simulation and experimental verifications.


  • Active Power Filter with Reduced Number of Semiconductor Switches Based on Synchronous Reference Frame

    by Abdellatif M. Aboutaleb, Haitham Z. Azazi, Dina S. M. Osheba, Awad E. El-Abbe

    In this paper a 3-phase shunt active power filter (SAPF) with reduced semiconductor switches based on synchronous reference frame (SRF) is introduced. The power circuit of SAPF contains only 4 switches, forming only two legs to compensate the load currents of two phases. The third leg is replaced by a split capacitor. SRF is used to calculate the reference currents, modifications are done to control the two capacitors voltages in the DC-link. The advantages of these modifications are simplifying the control circuit, reducing the total number of sensors and reducing the total cost of SAPF. Simulation studies using MATLAB/SIMULINK to verify the operation of the SAPF with the modified control circuit. Experimental setup is implanted to confirm the SAPF operation actually.