Şükriye Ulubay Karabiberoğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Şükriye Ulubay Karabiberoğlu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Zekerya Dursun
Faculty of Science Department of Chemistry Ege University Bornova İzmir 35100 Turkey
2 shared publications Karabiberoğlu
1 shared publicationMustafa Yiğit Bekmezci
Faculty of Science, Ege University, İzmir, Turkey
1 shared publicationZekerya Dursun
Faculty of Science, Ege University, İzmir, Turkey
1 shared publicationÇağri Ceylan Koçak
Dokuz Eylul Univ, Bergama Vocat Sch, Dept Occupat Hlth & Safety, Izmir, Turkey
1 shared publicationÇağrı Ceylan Koçak
Bergama Vocational School, Dokuz Eylul University, Izmir, Turkey
1 shared publication
Latest Publications
- 29 December 2025
- Published by Springer Nature in Monatshefte für Chemie - Chemical Monthly
- Vol. 157 (2) , 239-249
Amine-functionalized graphene oxide-modified electrode for sensitive acyclovir detection in pharmaceutical samples
- 29 December 2025
- Published by Springer Nature in Monatshefte für Chemie - Chemical Monthly
- Vol. 157 (2) , 239-249
Amine-functionalized graphene oxide-modified electrode for sensitive acyclovir detection in pharmaceutical samples
- 13 November 2018
- Published by Wiley in Electroanalysis
- Vol. 31 (1) , 91-102
Sensitive Voltammetric Determination of Bisphenol A Based on a Glassy Carbon Electrode Modified with Copper Oxide‐Zinc Oxide Decorated on Graphene Oxide
A highly sensitive and selective chemical sensor was prepared based on metallic copper‐copper oxides and zinc oxide decorated graphene oxide modified glassy carbon electrode (Cu−Zn/GO/GCE) through an easily electrochemical method for the quantification of bisphenol A (BPA). The composite electrode was characterized via scanning electron microscopy (SEM), X‐Ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). The electrochemical behavior of BPA in Britton‐Robinson (BR) buffer solution (pH 7.1) was examined using cyclic voltammetry (CV). Under optimized conditions, the square wave voltammetry (SWV) response of Cu−Zn/GO/GCE towards BPA indicates two linear relationships within concentrations (3.0 nmol L−1−0.1 μmol L−1 and 0.35 μmol L−1−20.0 μmol L−) and has a low detection limit (0.88 nmol L−1). The proposed electrochemical sensor based on Cu−Zn/GO/GCE is both time and cost effective, has good reproducibility, high selectivity as well as stability for BPA determination. The developed composite electrode was used to detect BPA in various samples including baby feeding bottle, pacifier, water bottle and food storage container and satisfactory results were obtained with high recoveries.
- 13 November 2018
- Published by Wiley in Electroanalysis
- Vol. 31 (1) , 91-102
Sensitive Voltammetric Determination of Bisphenol A Based on a Glassy Carbon Electrode Modified with Copper Oxide‐Zinc Oxide Decorated on Graphene Oxide
A highly sensitive and selective chemical sensor was prepared based on metallic copper‐copper oxides and zinc oxide decorated graphene oxide modified glassy carbon electrode (Cu−Zn/GO/GCE) through an easily electrochemical method for the quantification of bisphenol A (BPA). The composite electrode was characterized via scanning electron microscopy (SEM), X‐Ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). The electrochemical behavior of BPA in Britton‐Robinson (BR) buffer solution (pH 7.1) was examined using cyclic voltammetry (CV). Under optimized conditions, the square wave voltammetry (SWV) response of Cu−Zn/GO/GCE towards BPA indicates two linear relationships within concentrations (3.0 nmol L−1−0.1 μmol L−1 and 0.35 μmol L−1−20.0 μmol L−) and has a low detection limit (0.88 nmol L−1). The proposed electrochemical sensor based on Cu−Zn/GO/GCE is both time and cost effective, has good reproducibility, high selectivity as well as stability for BPA determination. The developed composite electrode was used to detect BPA in various samples including baby feeding bottle, pacifier, water bottle and food storage container and satisfactory results were obtained with high recoveries.
- 27 April 2018
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 42 (2) , 291-305
Voltammetric determination of vanillin in commercial food products using overoxidized poly(pyrrole) film-modified glassy carbon electrodes
- 27 April 2018
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 42 (2) , 291-305
Voltammetric determination of vanillin in commercial food products using overoxidized poly(pyrrole) film-modified glassy carbon electrodes
- 29 December 2016
- Published by Wiley in Electroanalysis
- Vol. 29 (4) , 1069-1080
Over‐Oxidized Poly (Phenol Red) Film Modified Glassy Carbon Electrode for Anodic Stripping Voltammetric Determination of Ultra‐Trace Antimony (III)
In this study, we introduce a very sensitive and selective method for the differential pulse anodic stripping determination of Sb(III) ion on the over‐oxidized poly(phenol red) modified glassy carbon electrode (PPhRedox/GCE) in 0.1 mol L‐1 HCl medium. The formation of both poly(phenol red) and over‐oxidized poly(phenol red) film on the electrode surfaces were characterized by electrochemical impedance spectroscopy, X‐ray photoelectron spectroscopy and scanning electron microscopy techniques. An anodic stripping peak of Sb(III) was observed at 0.015 V on the PPhRedox/GCE. Higher anodic stripping peak current of Sb(III) was obtained at PPhRedox/GCE compared with both bare GCE and poly(phenol red) film modified GCE (PPhRed/GCE). The calibration graph consisted of two linear segments of 0.044 ‐ 1.218 μg L−1 and 3.40 – 18.26 μg L−1 with a detection limit of 0.0075 μg L−1. The proposed over‐oxidized polymer film modified electrode was applied successfully for the analysis of antimony in different spiked water samples. Spiked recoveries for water samples were obtained in the range of 93.0–103.0%. The accuracy of the method was also verified through the analysis of standard reference materials (SCP SCIENCE‐EnviroMAT™ EP−L‐2).
- 29 December 2016
- Published by Wiley in Electroanalysis
- Vol. 29 (4) , 1069-1080
Over‐Oxidized Poly (Phenol Red) Film Modified Glassy Carbon Electrode for Anodic Stripping Voltammetric Determination of Ultra‐Trace Antimony (III)
In this study, we introduce a very sensitive and selective method for the differential pulse anodic stripping determination of Sb(III) ion on the over‐oxidized poly(phenol red) modified glassy carbon electrode (PPhRedox/GCE) in 0.1 mol L‐1 HCl medium. The formation of both poly(phenol red) and over‐oxidized poly(phenol red) film on the electrode surfaces were characterized by electrochemical impedance spectroscopy, X‐ray photoelectron spectroscopy and scanning electron microscopy techniques. An anodic stripping peak of Sb(III) was observed at 0.015 V on the PPhRedox/GCE. Higher anodic stripping peak current of Sb(III) was obtained at PPhRedox/GCE compared with both bare GCE and poly(phenol red) film modified GCE (PPhRed/GCE). The calibration graph consisted of two linear segments of 0.044 ‐ 1.218 μg L−1 and 3.40 – 18.26 μg L−1 with a detection limit of 0.0075 μg L−1. The proposed over‐oxidized polymer film modified electrode was applied successfully for the analysis of antimony in different spiked water samples. Spiked recoveries for water samples were obtained in the range of 93.0–103.0%. The accuracy of the method was also verified through the analysis of standard reference materials (SCP SCIENCE‐EnviroMAT™ EP−L‐2).
- 13 April 2016
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 20 (7) , 2009-2018
Highly catalytic activity of platinum-gold particles modified poly(p-aminophenol) electrode for oxygen reduction reaction
- 13 April 2016
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 20 (7) , 2009-2018
Highly catalytic activity of platinum-gold particles modified poly(p-aminophenol) electrode for oxygen reduction reaction