Sungyun Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sungyun Choi has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Yongju Son
School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea
12 shared publications - Myungseok Yoon
School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea
9 shared publications - Jintae Cho
KEPCO Research Institute (KEPRI), 105 Munji-ro, Yuseong-gu, Daejeon 34056, Republic of Korea
8 shared publications - Yeunggurl Yoon
School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea
7 shared publications Myungseok Yoon
5 shared publicationsXuehan Zhang
5 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (5) , 460-470
Energy sustainability of breast ultrasound: comparison of automated and handheld ultrasound systems
Purpose: This study evaluated and compared energy consumption between automated breast ultrasound (ABUS) and handheld ultrasound (HHUS) systems during routine whole-breast ultrasound (US) examinations in clinical practice.Methods: This prospective observational study included 320 consecutive patients who underwent breast US between July and October 2025. Four systems were used: two ABUS systems, designated ABUS-1 and ABUS-2, and two HHUS systems, designated HHUS-1 and HHUS-2. HHUS examinations were performed by four radiologists. Energy consumption was measured using a real-time power meter synchronized with system log files. Power consumption was analyzed in active, idle, and off modes. Average power in each mode, examination duration, and energy consumption during active scanning were calculated. Data were analyzed using the independent-samples t-test or Mann-Whitney U test with Bonferroni correction.Results: In idle mode, ABUS systems consumed significantly less average power than HHUS systems (P<0.001). In off mode, both ABUS systems consumed 0 W, whereas HHUS systems continued to consume residual power. During active scanning, ABUS systems had shorter examination durations than HHUS systems, with ABUS-1 showing the shortest duration. Energy consumption during active scanning was lowest for ABUS-1, which consumed approximately 47% less energy than HHUS-1 (P<0.001). Across all radiologists, both ABUS systems consistently showed lower energy consumption than HHUS-1.Conclusion: Compared with HHUS, ABUS showed lower power use in idle and off modes and similar or lower energy consumption during active scanning. When clinically appropriate, preferential use of ABUS may improve energy sustainability while preserving clinical utility.
- 1 September 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (5) , 460-470
Open AccessEnergy sustainability of breast ultrasound: comparison of automated and handheld ultrasound systems
Purpose: This study evaluated and compared energy consumption between automated breast ultrasound (ABUS) and handheld ultrasound (HHUS) systems during routine whole-breast ultrasound (US) examinations in clinical practice.Methods: This prospective observational study included 320 consecutive patients who underwent breast US between July and October 2025. Four systems were used: two ABUS systems, designated ABUS-1 and ABUS-2, and two HHUS systems, designated HHUS-1 and HHUS-2. HHUS examinations were performed by four radiologists. Energy consumption was measured using a real-time power meter synchronized with system log files. Power consumption was analyzed in active, idle, and off modes. Average power in each mode, examination duration, and energy consumption during active scanning were calculated. Data were analyzed using the independent-samples t-test or Mann-Whitney U test with Bonferroni correction.Results: In idle mode, ABUS systems consumed significantly less average power than HHUS systems (P<0.001). In off mode, both ABUS systems consumed 0 W, whereas HHUS systems continued to consume residual power. During active scanning, ABUS systems had shorter examination durations than HHUS systems, with ABUS-1 showing the shortest duration. Energy consumption during active scanning was lowest for ABUS-1, which consumed approximately 47% less energy than HHUS-1 (P<0.001). Across all radiologists, both ABUS systems consistently showed lower energy consumption than HHUS-1.Conclusion: Compared with HHUS, ABUS showed lower power use in idle and off modes and similar or lower energy consumption during active scanning. When clinically appropriate, preferential use of ABUS may improve energy sustainability while preserving clinical utility.
- Open Access
- 9 December 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (24) , 11027
Optimal Electrolyzer Placement Strategy via Probabilistic Voltage Stability Assessment in Renewable-Integrated Distribution Systems
Stable operating conditions in electrolyzers are crucial for preserving system durability, ensuring highly pure hydrogen production, and enabling the sustainable utilization of surplus renewable electricity. However, in active distribution networks, the output uncertainty of distributed energy resources, such as renewable energy sources (RES) on the generation side and load demand side, can lead to voltage fluctuations that threaten the operational stability of electrolyzers and limit their contribution to a low-carbon energy transition. This paper proposes a novel framework for optimal electrolyzer placement, tailored to their operational requirements and to the planning of sustainable renewable-integrated distribution systems. First, probabilistic scenario generation is carried out for RES and load to capture the characteristics of their inherent uncertainties. Second, based on these scenarios, continuous power-flow-based P–V (power–voltage) curve analysis is conducted to evaluate voltage stability and identify the loadability and load margin for each bus. Finally, the optimal siting of electrolyzers is determined by analyzing the load margins obtained from the voltage stability assessment and deriving a probabilistic electrolyzer hosting capacity. A case study under various uncertainty scenarios examines how applying this method influences the ability to maintain acceptable voltage levels at each bus in the grid. The results indicate that the method can significantly improve the likelihood of stable electrolyzer operation, support the reliable integration of green hydrogen production into distribution networks, and contribute to the sustainable planning of other voltage-sensitive equipment.
- 9 December 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (24) , 11027
Open AccessOptimal Electrolyzer Placement Strategy via Probabilistic Voltage Stability Assessment in Renewable-Integrated Distribution Systems
Stable operating conditions in electrolyzers are crucial for preserving system durability, ensuring highly pure hydrogen production, and enabling the sustainable utilization of surplus renewable electricity. However, in active distribution networks, the output uncertainty of distributed energy resources, such as renewable energy sources (RES) on the generation side and load demand side, can lead to voltage fluctuations that threaten the operational stability of electrolyzers and limit their contribution to a low-carbon energy transition. This paper proposes a novel framework for optimal electrolyzer placement, tailored to their operational requirements and to the planning of sustainable renewable-integrated distribution systems. First, probabilistic scenario generation is carried out for RES and load to capture the characteristics of their inherent uncertainties. Second, based on these scenarios, continuous power-flow-based P–V (power–voltage) curve analysis is conducted to evaluate voltage stability and identify the loadability and load margin for each bus. Finally, the optimal siting of electrolyzers is determined by analyzing the load margins obtained from the voltage stability assessment and deriving a probabilistic electrolyzer hosting capacity. A case study under various uncertainty scenarios examines how applying this method influences the ability to maintain acceptable voltage levels at each bus in the grid. The results indicate that the method can significantly improve the likelihood of stable electrolyzer operation, support the reliable integration of green hydrogen production into distribution networks, and contribute to the sustainable planning of other voltage-sensitive equipment.
- Open Access
Impact of Short Circuit Ratio on Harmonic Distortion in Offshore Wind Farm Integration
Offshore wind energy is rapidly expanding as a critical resource for global carbon neutrality, with 10.8 GW of new capacity added in 2023, raising the worldwide total to 75.2 GW. However, large-scale integration of offshore wind farms introduces power quality challenges due to the characteristics of inverter-based resources, particularly harmonic distortion, which can threaten system stability. This study quantitatively investigates the influence of short circuit ratio (SCR) on voltage and current harmonic distortion during offshore wind farm integration. A 500 MW offshore wind farm was modeled, and MATLAB/Simulink simulations were performed for 345 kV and 154 kV systems to evaluate the impact of varying SCR on total harmonic distortion (THD) and individual harmonic orders. Furthermore, the harmonic assessment based on the IEC 61400-21-2 summation method was compared with the simulation results, demonstrating the limitations of the simple summation approach and underscoring the importance of simulation-based evaluation. The results reveal that, under certain SCR conditions, parallel resonance caused by system impedance and line parameters produces unexpectedly high distortion in the 345 kV system, contrary to expectations based solely on voltage level. This resonance phenomenon and SCR dependency were also validated using short circuit capacity data from actual offshore wind farm candidate sites. Overall, the study emphasizes the necessity of comprehensive power quality assessments that account for SCR conditions, voltage levels, and harmonic emission characteristics, providing practical guidance for site selection, substation design, and harmonic mitigation in offshore wind integration.
Open AccessImpact of Short Circuit Ratio on Harmonic Distortion in Offshore Wind Farm Integration
Offshore wind energy is rapidly expanding as a critical resource for global carbon neutrality, with 10.8 GW of new capacity added in 2023, raising the worldwide total to 75.2 GW. However, large-scale integration of offshore wind farms introduces power quality challenges due to the characteristics of inverter-based resources, particularly harmonic distortion, which can threaten system stability. This study quantitatively investigates the influence of short circuit ratio (SCR) on voltage and current harmonic distortion during offshore wind farm integration. A 500 MW offshore wind farm was modeled, and MATLAB/Simulink simulations were performed for 345 kV and 154 kV systems to evaluate the impact of varying SCR on total harmonic distortion (THD) and individual harmonic orders. Furthermore, the harmonic assessment based on the IEC 61400-21-2 summation method was compared with the simulation results, demonstrating the limitations of the simple summation approach and underscoring the importance of simulation-based evaluation. The results reveal that, under certain SCR conditions, parallel resonance caused by system impedance and line parameters produces unexpectedly high distortion in the 345 kV system, contrary to expectations based solely on voltage level. This resonance phenomenon and SCR dependency were also validated using short circuit capacity data from actual offshore wind farm candidate sites. Overall, the study emphasizes the necessity of comprehensive power quality assessments that account for SCR conditions, voltage levels, and harmonic emission characteristics, providing practical guidance for site selection, substation design, and harmonic mitigation in offshore wind integration.
- Open Access
The Development of a MATLAB/Simulink-SCADA/EMS-Integrated Framework for Microgrid Pre-Validation
To validate microgrid systems, precise simulations are necessary beforehand. Traditional Hardware-in-the-Loop Simulation (HILS) is used to validate systems by creating a digital twin environment that integrates software and hardware to mimic reality. However, HILS requires high investment costs for hardware, posing a significant hurdle for companies. To address this issue, this study proposes a Software-in-the-Loop Simulation (SILS) framework using SCADA/EMS and MATLAB/Simulink(R2024a). The proposed SILS framework is highly compatible with Energy Management Systems (EMSs) and Supervisory Control and Data Acquisition (SCADA), allowing near real-time data exchange and scenario-based analysis without relying on physical hardware. According to the simulation results, SILS effectively replicates the dynamic behavior of microgrid components such as solar power generation systems, energy storage systems (ESSs), and diesel generators. Solution providers can quickly conduct feasibility tests through systems that simulate actual power systems. They can test the operation of SCADA/EMS at a lower cost and reduce on-site time, thereby reducing business costs and preemptively addressing potential issues in the field. This paper demonstrates how SILS can contribute to establishing optimal operation strategies and power supply stability through case studies, including daily operation optimization and autonomous operation scenarios for microgrids. This research provides a foundation for the feasibility of microgrid solution construction by enabling software performance evaluations and the verification of economic expected returns in the early stages of a project.
Open AccessThe Development of a MATLAB/Simulink-SCADA/EMS-Integrated Framework for Microgrid Pre-Validation
To validate microgrid systems, precise simulations are necessary beforehand. Traditional Hardware-in-the-Loop Simulation (HILS) is used to validate systems by creating a digital twin environment that integrates software and hardware to mimic reality. However, HILS requires high investment costs for hardware, posing a significant hurdle for companies. To address this issue, this study proposes a Software-in-the-Loop Simulation (SILS) framework using SCADA/EMS and MATLAB/Simulink(R2024a). The proposed SILS framework is highly compatible with Energy Management Systems (EMSs) and Supervisory Control and Data Acquisition (SCADA), allowing near real-time data exchange and scenario-based analysis without relying on physical hardware. According to the simulation results, SILS effectively replicates the dynamic behavior of microgrid components such as solar power generation systems, energy storage systems (ESSs), and diesel generators. Solution providers can quickly conduct feasibility tests through systems that simulate actual power systems. They can test the operation of SCADA/EMS at a lower cost and reduce on-site time, thereby reducing business costs and preemptively addressing potential issues in the field. This paper demonstrates how SILS can contribute to establishing optimal operation strategies and power supply stability through case studies, including daily operation optimization and autonomous operation scenarios for microgrids. This research provides a foundation for the feasibility of microgrid solution construction by enabling software performance evaluations and the verification of economic expected returns in the early stages of a project.
- Open Access
- 16 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5590
Design and Validation of a SiC-Based Single-to-Three-Phase Converter for Low-Voltage Distribution Systems
In areas such as remote, rural, and mountainous regions, supplying low-voltage three-phase power has traditionally required distribution line extension and transformer installation. However, these areas often yield low electricity revenues, making cost recovery difficult for utilities. To address this challenge, this paper proposes a Single-to-Three-Phase Converter (STPC) capable of converting single-phase low-voltage input into three-phase output for use in low-voltage distribution systems. The STPC topology employs a single-phase half-bridge AC–DC stage and a three-phase full-bridge inverter stage using SiC-MOSFETs. To validate the system, simulations and experiments were conducted under various load conditions, including unbalanced, nonlinear, and motor loads. The results show that STPC maintains output stability while minimizing impact on the existing grid. The findings demonstrate STPC’s feasibility as an alternative to conventional line extension and transformer installation, with potential for application in grid-forming and low-voltage distribution current (LVDC) systems.
- 16 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5590
Open AccessDesign and Validation of a SiC-Based Single-to-Three-Phase Converter for Low-Voltage Distribution Systems
In areas such as remote, rural, and mountainous regions, supplying low-voltage three-phase power has traditionally required distribution line extension and transformer installation. However, these areas often yield low electricity revenues, making cost recovery difficult for utilities. To address this challenge, this paper proposes a Single-to-Three-Phase Converter (STPC) capable of converting single-phase low-voltage input into three-phase output for use in low-voltage distribution systems. The STPC topology employs a single-phase half-bridge AC–DC stage and a three-phase full-bridge inverter stage using SiC-MOSFETs. To validate the system, simulations and experiments were conducted under various load conditions, including unbalanced, nonlinear, and motor loads. The results show that STPC maintains output stability while minimizing impact on the existing grid. The findings demonstrate STPC’s feasibility as an alternative to conventional line extension and transformer installation, with potential for application in grid-forming and low-voltage distribution current (LVDC) systems.
- Open Access
- 15 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (10) , 4506
A Pricing Strategy for Key Customers: A Method Considering Disaster Outage Compensation and System Stability Penalty
When power system equipment fails due to disasters, resulting in the isolation of parts of the network, the loads within the isolated system cannot be guaranteed a continuous power supply. However, for critical loads—such as hospitals or data centers—continuous power supply is of utmost importance. While distributed energy resources (DERs) within the network can supply power to some loads, outages may lead to compensation and fairness issues regarding the unsupplied loads. In response, this study proposes a methodology to determine the appropriate power contract price for key customers by estimating the unsupplied power demand for critical loads in isolated networks and incorporating both outage compensation costs and voltage stability penalties. The microgrid under consideration comprises DERs—including electric vehicles (EVs), fuel cell electric vehicles (FCEVs), photovoltaic (PV) plants, and wind turbine (WT) plants—as well as controllable resources such as battery energy storage systems (BESS) and hydrogen energy storage systems (HESS). It serves both residential load clusters and critical loads associated with social infrastructure. The proposed methodology is structured in two stages. In normal operating conditions, optimal scheduling is simulated using second-order conic programming (SOCP). In the event of a fault, mixed-integer SOCP (MISOCP) is employed to determine the optimal load shedding strategy. A case study is conducted using the IEEE 123 bus test node system to simulate the outage compensation cost calculation and voltage penalty assessment processes. Based on this analysis, a contract price for key customers that considers both disaster-induced outages and voltage impacts is presented.
- 15 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (10) , 4506
Open AccessA Pricing Strategy for Key Customers: A Method Considering Disaster Outage Compensation and System Stability Penalty
When power system equipment fails due to disasters, resulting in the isolation of parts of the network, the loads within the isolated system cannot be guaranteed a continuous power supply. However, for critical loads—such as hospitals or data centers—continuous power supply is of utmost importance. While distributed energy resources (DERs) within the network can supply power to some loads, outages may lead to compensation and fairness issues regarding the unsupplied loads. In response, this study proposes a methodology to determine the appropriate power contract price for key customers by estimating the unsupplied power demand for critical loads in isolated networks and incorporating both outage compensation costs and voltage stability penalties. The microgrid under consideration comprises DERs—including electric vehicles (EVs), fuel cell electric vehicles (FCEVs), photovoltaic (PV) plants, and wind turbine (WT) plants—as well as controllable resources such as battery energy storage systems (BESS) and hydrogen energy storage systems (HESS). It serves both residential load clusters and critical loads associated with social infrastructure. The proposed methodology is structured in two stages. In normal operating conditions, optimal scheduling is simulated using second-order conic programming (SOCP). In the event of a fault, mixed-integer SOCP (MISOCP) is employed to determine the optimal load shedding strategy. A case study is conducted using the IEEE 123 bus test node system to simulate the outage compensation cost calculation and voltage penalty assessment processes. Based on this analysis, a contract price for key customers that considers both disaster-induced outages and voltage impacts is presented.
- Open Access
Selecting an Installation Site for MW-Scale Water Electrolysis Systems Based on Grid Voltage Stability
Worldwide, efforts are underway to produce hydrogen from water electrolysis, moving beyond the traditional reforming of fossil fuels. Renewable energy-powered hydrogen production is possible, but the use of grid power is also being considered for large-scale production. Additionally, some demonstration projects aim to utilize electrolysis systems as auxiliary service resources to enhance stability in the grid, given the rising share of renewable energy. This study proposes a method for connecting electrolysis facilities to the grid based on voltage stability analysis. The method involves analyzing the grid power parameters required by the electrolyzer and fault scenarios where low voltage could cause system shutdowns, as observed in actual case studies. By conducting voltage stability analysis simulations that incorporate these fault scenarios, the method identifies locations where the electrolyzer can operate stably within power grids. This approach aims to ensure the stable operation of electrolysis facilities even under conditions of renewable energy loss and low-voltage occurrences in the distribution system due to potential transmission system failures.
Open AccessSelecting an Installation Site for MW-Scale Water Electrolysis Systems Based on Grid Voltage Stability
Worldwide, efforts are underway to produce hydrogen from water electrolysis, moving beyond the traditional reforming of fossil fuels. Renewable energy-powered hydrogen production is possible, but the use of grid power is also being considered for large-scale production. Additionally, some demonstration projects aim to utilize electrolysis systems as auxiliary service resources to enhance stability in the grid, given the rising share of renewable energy. This study proposes a method for connecting electrolysis facilities to the grid based on voltage stability analysis. The method involves analyzing the grid power parameters required by the electrolyzer and fault scenarios where low voltage could cause system shutdowns, as observed in actual case studies. By conducting voltage stability analysis simulations that incorporate these fault scenarios, the method identifies locations where the electrolyzer can operate stably within power grids. This approach aims to ensure the stable operation of electrolysis facilities even under conditions of renewable energy loss and low-voltage occurrences in the distribution system due to potential transmission system failures.
- Open Access
- 21 January 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 165
Strategic intentional islanding method considering temporary overvoltage in disaster situations
- 21 January 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 165
Open AccessStrategic intentional islanding method considering temporary overvoltage in disaster situations