Alfred Svarc
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alfred Svarc has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
S. Ceci
Rudjer Bošković Institute Bijenička cesta 54 P.O. Box 180 10002 Zagreb Croatia
13 shared publicationsB. Zauner
10 shared publicationsJugoslav Stahov
Faculty of Science University of Tuzla Univerzitetska 4 75000 Tuzla Bosnia and Herzegovina
10 shared publicationsM. Hadžimehmedović
University of Tuzla, Faculty of Natural Sciences and Mathematics, Univerzitetska 4, 75000 Tuzla, Bosnia and Herzegovina
10 shared publicationsJ. Stahov
University of Tuzla, Faculty of Natural Sciences and Mathematics, Univerzitetska 4, 75000 Tuzla, Bosnia and Herzegovina
9 shared publicationsH. Osmanović
University of Tuzla, Faculty of Natural Sciences and Mathematics, Univerzitetska 4, 75000 Tuzla, Bosnia and Herzegovina
8 shared publications
Latest Publications
- Open Access
- 10 February 2026
- Published by Jagiellonian University in Acta Physica Polonica B
- Vol. 57 (2)
Complete Set of Observables in Pseudo-scalar Meson Photoproduction; Controversy Solved
The long-standing debate over whether the complete set of observables in pseudo-scalar meson photoproduction consists of eight or merely four elements continues to persist. From the perspective of amplitude analysis, it is argued that all eight observables are necessary to completely determine the others. On the other hand, proponents of partial-wave analysis, working with theoretically precise data of infinite accuracy, claim that only four observables are needed. However, this claim is not acceptable from an experimental viewpoint, as all data in the real world contain some uncertainty. This paper illustrates that the controversy is artificial and is due to additional mathematical assumptions used in partial-wave analysis. Our research advances this discussion by moving from exact synthetic numerical data to also synthetic, but more realistic data in partial-wave analysis and shows that the claimed reduction in observables is unjustified. Consequently, the final conclusion is that the complete set of observables in pseudo-scalar meson photoproduction, whether using amplitude analysis or partial-wave analysis with practical data, must consist of eight observables. Published by the Jagiellonian University 2026 authors
- 10 February 2026
- Published by Jagiellonian University in Acta Physica Polonica B
- Vol. 57 (2)
Open AccessComplete Set of Observables in Pseudo-scalar Meson Photoproduction; Controversy Solved
The long-standing debate over whether the complete set of observables in pseudo-scalar meson photoproduction consists of eight or merely four elements continues to persist. From the perspective of amplitude analysis, it is argued that all eight observables are necessary to completely determine the others. On the other hand, proponents of partial-wave analysis, working with theoretically precise data of infinite accuracy, claim that only four observables are needed. However, this claim is not acceptable from an experimental viewpoint, as all data in the real world contain some uncertainty. This paper illustrates that the controversy is artificial and is due to additional mathematical assumptions used in partial-wave analysis. Our research advances this discussion by moving from exact synthetic numerical data to also synthetic, but more realistic data in partial-wave analysis and shows that the claimed reduction in observables is unjustified. Consequently, the final conclusion is that the complete set of observables in pseudo-scalar meson photoproduction, whether using amplitude analysis or partial-wave analysis with practical data, must consist of eight observables. Published by the Jagiellonian University 2026 authors
- Open Access
Complete set of observables in pseudo-scalar meson photoproduction -- Controversy solved
The long-standing debate over whether the complete set of observables in pseudo-scalar meson photoproduction consists of eight or merely four elements continues to persist. From the perspective of amplitude analysis, it is argued that all eight observables are necessary to completely determine the others. On the other hand, proponents of partial-wave analysis, working with theoretically precise data of infinite accuracy, claim that only four observables are needed. However, this claim is not acceptable from an experimental viewpoint, as all data in the real world contain some uncertainty. This paper illustrates that the controversy is artificial and is due to additional mathematical assumptions used in partial-wave analysis. Our research advances this discussion by moving from exact synthetic numerical data to also synthetic, but more realistic data in partial-wave analysis and shows that the claimed reduction in observables is unjustified. Consequently, the final conclusion is that the complete set of observables in pseudo-scalar meson photoproduction, whether using amplitude analysis or partial-wave analysis with practical data, must consist of eight observables.
Open AccessComplete set of observables in pseudo-scalar meson photoproduction -- Controversy solved
The long-standing debate over whether the complete set of observables in pseudo-scalar meson photoproduction consists of eight or merely four elements continues to persist. From the perspective of amplitude analysis, it is argued that all eight observables are necessary to completely determine the others. On the other hand, proponents of partial-wave analysis, working with theoretically precise data of infinite accuracy, claim that only four observables are needed. However, this claim is not acceptable from an experimental viewpoint, as all data in the real world contain some uncertainty. This paper illustrates that the controversy is artificial and is due to additional mathematical assumptions used in partial-wave analysis. Our research advances this discussion by moving from exact synthetic numerical data to also synthetic, but more realistic data in partial-wave analysis and shows that the claimed reduction in observables is unjustified. Consequently, the final conclusion is that the complete set of observables in pseudo-scalar meson photoproduction, whether using amplitude analysis or partial-wave analysis with practical data, must consist of eight observables.
- 27 August 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 110 (2)
Single-channel and single-energy partial-wave analysis with continuity improved through minimal phase constraints
- 27 August 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 110 (2)
Single-channel and single-energy partial-wave analysis with continuity improved through minimal phase constraints
- 26 July 2023
- Published by American Physical Society (APS) in Physical Review C
- Vol. 108 (1) , 014615
Laurent+Pietarinen partial-wave analysis
A new energy-dependent fit strategy, independent of any specific microscopic theory, is applied to kaon photoproduction data with center-of-mass energies ranging from 1625 MeV to 2296 MeV. Experimental data are fitted in terms of a modified Laurent expansion (Laurent+Pietarinen expansion) which previously has been successfully applied to multipoles. The present aim is to extract resonance pole parameters directly from the data, rather than from sets of multipoles. A constrained single-energy fit is then used to search for missing structures. In this proof-of-principle study, the data are well described by the initial fit, and it is shown that only a moderate amount of structure, mostly in higher multipoles, is missing from the original fit. Problems due to an unmeasurable overall phase, plaguing single-channel multipole analyses, are mitigated by implementing a form of phase limitation, fixing the initial values of fit parameters using a multichannel analysis.- 26 July 2023
- Published by American Physical Society (APS) in Physical Review C
- Vol. 108 (1) , 014615
Laurent+Pietarinen partial-wave analysis
A new energy-dependent fit strategy, independent of any specific microscopic theory, is applied to kaon photoproduction data with center-of-mass energies ranging from 1625 MeV to 2296 MeV. Experimental data are fitted in terms of a modified Laurent expansion (Laurent+Pietarinen expansion) which previously has been successfully applied to multipoles. The present aim is to extract resonance pole parameters directly from the data, rather than from sets of multipoles. A constrained single-energy fit is then used to search for missing structures. In this proof-of-principle study, the data are well described by the initial fit, and it is shown that only a moderate amount of structure, mostly in higher multipoles, is missing from the original fit. Problems due to an unmeasurable overall phase, plaguing single-channel multipole analyses, are mitigated by implementing a form of phase limitation, fixing the initial values of fit parameters using a multichannel analysis.- Open Access
Laurent+Pietarinen Partial Wave Analysis
A new energy-dependent fit strategy, independent of any specific microscopic theory, is applied to kaon photoproduction data with center-of-mass energies ranging from 1625 MeV to 2296 MeV. Experimental data are fitted in terms of a modified Laurent expansion (Laurent+Pietarinen expansion) which previously has been successfully applied to multipoles. The present aim is to extract resonance pole parameters directly from the data, rather than from sets of multipoles. A constrained single-energy fit is then used to search for missing structures. In this proof-of-principle study, the data are well-described by the initial L+P fit, and it is shown that only a moderate amount of structure, mostly in higher multipoles, is missing from the original fit. Problems due to an unmeasurable overall phase, plaguing single-channel multipole analyses, are mitigated by implementing a form of phase limitation, fixing the initial values of fit parameters using a multi-channel analysis.
Open AccessLaurent+Pietarinen Partial Wave Analysis
A new energy-dependent fit strategy, independent of any specific microscopic theory, is applied to kaon photoproduction data with center-of-mass energies ranging from 1625 MeV to 2296 MeV. Experimental data are fitted in terms of a modified Laurent expansion (Laurent+Pietarinen expansion) which previously has been successfully applied to multipoles. The present aim is to extract resonance pole parameters directly from the data, rather than from sets of multipoles. A constrained single-energy fit is then used to search for missing structures. In this proof-of-principle study, the data are well-described by the initial L+P fit, and it is shown that only a moderate amount of structure, mostly in higher multipoles, is missing from the original fit. Problems due to an unmeasurable overall phase, plaguing single-channel multipole analyses, are mitigated by implementing a form of phase limitation, fixing the initial values of fit parameters using a multi-channel analysis.
- 22 February 2022
- Published by American Physical Society (APS) in Physical Review C
- Vol. 105 (2) , 024614
Application of the single-channel, single-energy amplitude and partial-wave analysis method to photoproductionThe new single-channel, single-energy partial-wave analysis method based on a simultaneous use of amplitude and partial-wave analysis called AA-PWA, developed and tested on photoproduction in [ Phys. Rev. C 102, 064609 (2020)] is applied to the photoproduction for the center-of-mass energy range of . A complete set of multipoles has been created. The advantages of the method have been confirmed and a comparison with the only existing single-energy partial-wave analysis of photoproduction given in [ Phys. Rev. Lett. 119, 062004 (2017), Eur. Phys. J. A 53, 242 (2017)] is presented. We confirm the size and shape of Bonn-Gatchina multipoles, but we do not confirm the unambiguous interpretation of the structure in the multipole as a resonance. The decisive role of the self-consistency of the world database is emphasized.- 22 February 2022
- Published by American Physical Society (APS) in Physical Review C
- Vol. 105 (2) , 024614
Application of the single-channel, single-energy amplitude and partial-wave analysis method to photoproductionThe new single-channel, single-energy partial-wave analysis method based on a simultaneous use of amplitude and partial-wave analysis called AA-PWA, developed and tested on photoproduction in [ Phys. Rev. C 102, 064609 (2020)] is applied to the photoproduction for the center-of-mass energy range of . A complete set of multipoles has been created. The advantages of the method have been confirmed and a comparison with the only existing single-energy partial-wave analysis of photoproduction given in [ Phys. Rev. Lett. 119, 062004 (2017), Eur. Phys. J. A 53, 242 (2017)] is presented. We confirm the size and shape of Bonn-Gatchina multipoles, but we do not confirm the unambiguous interpretation of the structure in the multipole as a resonance. The decisive role of the self-consistency of the world database is emphasized.- 7 July 2021
- Published by American Physical Society (APS) in Physical Review C
- Vol. 104 (1) , 014605
Each single-energy, single-channel partial-wave analysis is inherently model-dependent
Švarc et al. [ Phys. Rev. C 97, 054611 (2018)] have shown that without fixing the reaction-amplitude phase, different partial waves at neighboring energies in single-energy, single-channel partial wave analysis reproduce experimental data identically, but are discontinuous and disconnected. To obtain the continuous solution, the phase has to be fixed to some continuous value. In the same reference it has also been shown that the change of the angular part of the reaction-amplitude phase mixes partial waves, so the pole structure of any single-energy single-channel partial wave analysis depends on the chosen phase. As in any single-channel analysis the overall reaction-amplitude phase cannot be determined because of continuum ambiguity, it is in principle free and has to be taken from some coupled-channel model. Because of the difference in the angular part of the phase, choosing different phases results in the change of the pole content of the obtained solution. Therefore, single-energy single-channel partial wave analysis is inherently model dependent, and the number of poles it contains strongly depends on the choice of the phase. In that reference these facts have been illustrated on the pseudoscalar meson production toy model. This truth is now for the full set of measured observables demonstrated on the realistic model of photoproduction presented in Švarc, Wunderlich, and Tiator [ Phys. Rev. C 102, 064609 (2020)].- 7 July 2021
- Published by American Physical Society (APS) in Physical Review C
- Vol. 104 (1) , 014605
Each single-energy, single-channel partial-wave analysis is inherently model-dependent
Švarc et al. [ Phys. Rev. C 97, 054611 (2018)] have shown that without fixing the reaction-amplitude phase, different partial waves at neighboring energies in single-energy, single-channel partial wave analysis reproduce experimental data identically, but are discontinuous and disconnected. To obtain the continuous solution, the phase has to be fixed to some continuous value. In the same reference it has also been shown that the change of the angular part of the reaction-amplitude phase mixes partial waves, so the pole structure of any single-energy single-channel partial wave analysis depends on the chosen phase. As in any single-channel analysis the overall reaction-amplitude phase cannot be determined because of continuum ambiguity, it is in principle free and has to be taken from some coupled-channel model. Because of the difference in the angular part of the phase, choosing different phases results in the change of the pole content of the obtained solution. Therefore, single-energy single-channel partial wave analysis is inherently model dependent, and the number of poles it contains strongly depends on the choice of the phase. In that reference these facts have been illustrated on the pseudoscalar meson production toy model. This truth is now for the full set of measured observables demonstrated on the realistic model of photoproduction presented in Švarc, Wunderlich, and Tiator [ Phys. Rev. C 102, 064609 (2020)].- 10 December 2020
- Published by American Physical Society (APS) in Physical Review C
- Vol. 102 (6) , 064609
Amplitude- and truncated partial-wave analyses combined: A single-channel method for extracting photoproduction multipoles directly from measured data
Amplitude- and truncated partial-wave analyses are combined into a single-channel method for extracting multipoles directly from measured data. In practice, we have created a two-step procedure which is fit to the same database: in the first step we perform an energy-independent amplitude analysis where continuity is achieved by constraining the amplitude phase, and the result of this first step is then taken as a constraint for the second step where a constrained, energy-independent, truncated partial-wave analysis is done. The method is tested on the world collection of data for photoproduction, and the obtained fit results are very good. The sensitivity to different possible choices of amplitude phase is investigated and it is demonstrated that the present database is insensitive to notable phase changes due to an incomplete database. New measurements are recommended to remedy the problem.- 10 December 2020
- Published by American Physical Society (APS) in Physical Review C
- Vol. 102 (6) , 064609
Amplitude- and truncated partial-wave analyses combined: A single-channel method for extracting photoproduction multipoles directly from measured data
Amplitude- and truncated partial-wave analyses are combined into a single-channel method for extracting multipoles directly from measured data. In practice, we have created a two-step procedure which is fit to the same database: in the first step we perform an energy-independent amplitude analysis where continuity is achieved by constraining the amplitude phase, and the result of this first step is then taken as a constraint for the second step where a constrained, energy-independent, truncated partial-wave analysis is done. The method is tested on the world collection of data for photoproduction, and the obtained fit results are very good. The sensitivity to different possible choices of amplitude phase is investigated and it is demonstrated that the present database is insensitive to notable phase changes due to an incomplete database. New measurements are recommended to remedy the problem.- Open Access
- 22 September 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 241, 03005
From Experimental Data to Pole Parameters in a Model Independent Way (Fixed-t Single-Energy Partial Wave Analysis (SE PWA) and Laurent + Pietarinen Model (L+P) for Pole Extraction)
As it has been shown in the invited talk at the NSTAR-2017 conference [1] it is in principle possible to extract pole parameters directly from experiment with minimal model dependence, and in this contribution one way to achieve it in practice by fixed-t analyticity has been demonstrated. Namely, unconstrained partial- wave amplitudes obtained at discrete energies from fits even to complete sets of independent observables which are required to uniquely reconstruct reaction amplitudes do not vary smoothly with energy, and are in prin ciple non-unique. We have demonstrated that this behavior can be ascribed to the continuum ambiguity. We have applied continuum ambiguity invariance to pseudo-scalar meson photoproduction and showed that for a complete set of pseudo-data the non-uniqueness effect can be removed through a phase rotation generating “up-to-a-phase” unique set of single energy partial wave amplitudes. Now we show that for real data this method does not work, but another approach - fixed-t analyticity solves the problem. We present the final results for theηandπ0-photoproduction [2, 3]. Extracting pole positions from partial wave amplitudes is the next step, and we summarize the essence of the new, Laurent + Pietarinen expansion method applicable for continuous and discrete data. It is based on applying the Laurent decomposition of partial wave amplitude, and expanding the non-resonant background into a power series of a conformal-mapping-generated, quickly converging power series obtaining the simplest analytic function with well-defined partial wave analytic properties which fits the input. Unifying both methods in succession, one constructs a model independent procedure to extract pole parameters directly from experimental data without referring to any theoretical model.
- 22 September 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 241, 03005
Open AccessFrom Experimental Data to Pole Parameters in a Model Independent Way (Fixed-t Single-Energy Partial Wave Analysis (SE PWA) and Laurent + Pietarinen Model (L+P) for Pole Extraction)
As it has been shown in the invited talk at the NSTAR-2017 conference [1] it is in principle possible to extract pole parameters directly from experiment with minimal model dependence, and in this contribution one way to achieve it in practice by fixed-t analyticity has been demonstrated. Namely, unconstrained partial- wave amplitudes obtained at discrete energies from fits even to complete sets of independent observables which are required to uniquely reconstruct reaction amplitudes do not vary smoothly with energy, and are in prin ciple non-unique. We have demonstrated that this behavior can be ascribed to the continuum ambiguity. We have applied continuum ambiguity invariance to pseudo-scalar meson photoproduction and showed that for a complete set of pseudo-data the non-uniqueness effect can be removed through a phase rotation generating “up-to-a-phase” unique set of single energy partial wave amplitudes. Now we show that for real data this method does not work, but another approach - fixed-t analyticity solves the problem. We present the final results for theηandπ0-photoproduction [2, 3]. Extracting pole positions from partial wave amplitudes is the next step, and we summarize the essence of the new, Laurent + Pietarinen expansion method applicable for continuous and discrete data. It is based on applying the Laurent decomposition of partial wave amplitude, and expanding the non-resonant background into a power series of a conformal-mapping-generated, quickly converging power series obtaining the simplest analytic function with well-defined partial wave analytic properties which fits the input. Unifying both methods in succession, one constructs a model independent procedure to extract pole parameters directly from experimental data without referring to any theoretical model.