Hani Sadrhosseini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hani Sadrhosseini has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ali Moosavi
Center of Excellence in Energy Conversion (CEEC), Faculty of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
1 shared publication - Ali Mousavi
Sharif University of Technology
1 shared publication Amir Hossein Beigi
Sharif University of Technology
1 shared publication- Saed Bazkhane
(Department of Mechanical Engineering, Sharif University of Technology, Kish Island, Iran
1 shared publication - Seyed Mostafa Banihashemi Tehrani
Department of Engineering and Science, Sharif University of Technology, International Campus, Kish Island, Iran
1 shared publication
Latest Publications
- Open Access
- 1 January 2020
- Published by Universidad de Santander - UDES in Innovaciencia
- Vol. 8 (1) , 1-7
Optimization of side stream filters of blow-down water in cooling water system
Introduction Cooling towers are the main parameters for oil and gas industries. The water that circulates the system will pass through heat exchangers and surface condenser of compressor. Cooling towers operate outside; there is a high chance of debris entering the system and water via wind which therefore could lead to fouling, scaling and corrosion. In order for cooling towers to perform at high efficiency, the water has to be clean. Filtration package are the key for solving this matter. Material and Methods In this thesis, a new filtration package for Marjan petrochemical company has been proposed. In this design the blow down water of the cooling tower will be filtered via first a side stream filtration unit. Results It which will decrease the TSS of the water and then enters a Reverse Osmosis package which will reduce the TDS of the water. From the Hysys simulation, it has been proven that this system will produce 63 m3/hr pure water and 37 m3/hr brain water. Conclusion The compositions of these water are 97% pure water and 3% debris, 96% debris and 4% water respectively. This showed that the filtration package decreased the TDS of the water to 4 ppm which is the specification of the make-up water of cooling tower. Financially, when there is no package installed, Marjan has to send COC and POC waters to Mobin Company for filtrations and then buy the RO water.
- 1 January 2020
- Published by Universidad de Santander - UDES in Innovaciencia
- Vol. 8 (1) , 1-7
Open AccessOptimization of side stream filters of blow-down water in cooling water system
Introduction Cooling towers are the main parameters for oil and gas industries. The water that circulates the system will pass through heat exchangers and surface condenser of compressor. Cooling towers operate outside; there is a high chance of debris entering the system and water via wind which therefore could lead to fouling, scaling and corrosion. In order for cooling towers to perform at high efficiency, the water has to be clean. Filtration package are the key for solving this matter. Material and Methods In this thesis, a new filtration package for Marjan petrochemical company has been proposed. In this design the blow down water of the cooling tower will be filtered via first a side stream filtration unit. Results It which will decrease the TSS of the water and then enters a Reverse Osmosis package which will reduce the TDS of the water. From the Hysys simulation, it has been proven that this system will produce 63 m3/hr pure water and 37 m3/hr brain water. Conclusion The compositions of these water are 97% pure water and 3% debris, 96% debris and 4% water respectively. This showed that the filtration package decreased the TDS of the water to 4 ppm which is the specification of the make-up water of cooling tower. Financially, when there is no package installed, Marjan has to send COC and POC waters to Mobin Company for filtrations and then buy the RO water.
- 3 January 2017
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- Vol. 27 (1) , 142-155
Simplified model for polyurethane foaming in porous media
Purpose The purpose of the study is to present a simplified model to replace the complicated foaming simulations for investigating the liquid polyurethane behavior just before solidification. Design/methodology/approach This model is inspired from the traveling heater method of crystallization because of the low injection velocity. Besides, the heat generated during the reaction is considered as a heat source function in the energy equation. Findings Various distributions of the heat generation function inside the geometry have been studied to choose the most realistic one. Effect of parameters such as the soil material and porosity on the temperature distribution and flow field are examined for different values of heat flux on the boundaries. Results show an almost linear dependency of pressure drop to the velocity, a uniform velocity profile and an expected temperature distribution compared to literature, which approves the suggested model. Originality/value A new model is presented in this study for foaming which replaces a heat generation function (exponential) in the source term of the energy equation instead of the heat produced at the exit boundary (the solid–liquid interface), and the traveling method is used instead of moving the geometry; besides, the growth ratio has been neglected; therefore, this model has been validated by a foaming simulation to confirm the suggested simplified idea.
- 3 January 2017
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- Vol. 27 (1) , 142-155
Simplified model for polyurethane foaming in porous media
Purpose The purpose of the study is to present a simplified model to replace the complicated foaming simulations for investigating the liquid polyurethane behavior just before solidification. Design/methodology/approach This model is inspired from the traveling heater method of crystallization because of the low injection velocity. Besides, the heat generated during the reaction is considered as a heat source function in the energy equation. Findings Various distributions of the heat generation function inside the geometry have been studied to choose the most realistic one. Effect of parameters such as the soil material and porosity on the temperature distribution and flow field are examined for different values of heat flux on the boundaries. Results show an almost linear dependency of pressure drop to the velocity, a uniform velocity profile and an expected temperature distribution compared to literature, which approves the suggested model. Originality/value A new model is presented in this study for foaming which replaces a heat generation function (exponential) in the source term of the energy equation instead of the heat produced at the exit boundary (the solid–liquid interface), and the traveling method is used instead of moving the geometry; besides, the growth ratio has been neglected; therefore, this model has been validated by a foaming simulation to confirm the suggested simplified idea.
- 24 September 2015
- Published by Springer Nature in Microsystem Technologies
- Vol. 22 (5) , 965-977
Filtration of aerosol particles by cylindrical fibers within a parallel and staggered array
- 24 September 2015
- Published by Springer Nature in Microsystem Technologies
- Vol. 22 (5) , 965-977
Filtration of aerosol particles by cylindrical fibers within a parallel and staggered array