SGSotirios P. Gartaganis

Sotirios P. Gartaganis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sotirios P. Gartaganis has a total of 56 co-authors. Here are the top co-authors by number of shared publications:

  • A. Exarchou

    Department of Ophthalmology, University of Patras Medical School, Rion, Patras, Greece; Laboratory of Biochemistry, Department of Chemistry, University of Patras, Patras Greece; Department of Ophthalmology, University of Athens Medical School, Athens, Greece; Department of Pathology and Microbiology, University of South Carolina School of Medicine, South Carolina, USA; Department of Ophthalmology, University of South Carolina School of Medicine, South Carolina, USA

    3 shared publications
  • C. D. Georgakopoulos

    Department of Ophthalmology, School of Medicine, University of Patras, PatrasGreece

    3 shared publications
  • C.D. Georgakopoulos

    Department of Ophthalmology, University of Patras Medical School, Rion, Patras, Greece; Laboratory of Biochemistry, Department of Chemistry, University of Patras, Patras Greece; Department of Ophthalmology, University of Athens Medical School, Athens, Greece; Department of Pathology and Microbiology, University of South Carolina School of Medicine, South Carolina, USA; Department of Ophthalmology, University of South Carolina School of Medicine, South Carolina, USA

    3 shared publications
  • E.K. Mela

    Department of Ophthalmology, University of Patras Medical School, Rion, Patras, Greece; Laboratory of Biochemistry, Department of Chemistry, University of Patras, Patras Greece; Department of Ophthalmology, University of Athens Medical School, Athens, Greece; Department of Pathology and Microbiology, University of South Carolina School of Medicine, South Carolina, USA; Department of Ophthalmology, University of South Carolina School of Medicine, South Carolina, USA

    3 shared publications
  • Panagiota D. Natsi

    Department of Chemical Engineering, University of Patras, GR-26504 Patras, Greece

    3 shared publications
  • Panos S. Gartaganis

    Medical Retina Service, Western Eye Hospital, Imperial College Healthcare NHS Trust, London, GBR

    3 shared publications

Latest Publications

  • Open Access

    Graphene-Derivative Coatings for the Prevention of Opacification Due to Calcification of Hydrophilic Intraocular Lenses

    by Panagiota D. Natsi, Menelaos Kanakis, Labrini Sygellou, Panos S. Gartaganis, Sotirios P. Gartaganis, Petros G. Koutsoukos

    The widespread use of hydrophilic intraocular lenses (IOLs) in eye surgery, fabricated by poly-2-(hydroxyethyl methacrylate) (PHEMA), has highlighted their calcification as a serious problem, implying that their surgical explantation is a rather risky process. The field of biomaterials has been developing rapidly in recent years, with research interest turning to the development of novel materials which involve either copolymers of PHEMA or protective functional coatings. Graphene coatings are particularly attractive because of their respective unique properties. In the present work, we present the results of the investigation of the development of graphene coatings on hydrophilic IOLs and their subsequent performance with respect to calcification opacification. Hydrophilic IOLs with a water content of 18% by weight were coated with graphene oxide (GO) by equilibration with GO suspensions in water. The concentrations of the suspensions ranged from 1 × 10−4 to 20 × 10−4% w/v. The GO suspensions were equilibrated with the IOLs for 5 days at a constant temperature, 37 °C, and rotated in 30 mL tubes end over end. This treatment resulted in the formation of a uniform coating of GO on the IOLs verified by scanning electron microscopy (SEM) and other physicochemical methods. The contact angle of the GO-coated IOLs decreased significantly in comparison with the uncoated IOLs. The GO-coated IOLs exhibited a higher tendency to calcify in supersaturated solutions simulating aqueous humor (SAH). The growth rate of hydroxyapatite (Ca5(PO4)3OH, HAP) on GO-coated IOLs was higher in comparison with the respective untreated IOLs. The conversion of the GO coating via a reduction with phenyl hydrazine resulted in the formation of a reduced-graphene (rGO) surface film, as identified by Raman and XPS spectroscopy. The rGO film was hydrophobic (contact angle 100°) and did not calcify in supersaturated calcium phosphate solutions.


  • Open Access

    Graphene Derivatives Coatings for the Prevention of Opacification Due to Calcification of Hydrophilic Intraocular Lenses

    by Panagiota D Natsi, Menelaos Kanakis, Labrini Sygellou, Panos S Gartaganis, Sotirios P Gartaganis, Petros G Koutsoukos

    The widespread use of hydrophilic intraocular lenses (IOL) in eye surgery, fabricated by poly-2- (hydroxyethylmethacrylic acid) (PHEMA), has highlighted their calcification as a serious problem, which implies their surgical explantation a rather risky process. The field of biomaterials has been developing rapidly in recent years with research interest turning to the development of novel ma-terials which involve either copolymers of PHEMA or protective functional coatings. Graphene coatings are particularly attractive because of the respective unique properties. In the present work we present the results of the investigation of the development of graphene coatings on hydrophilic IOLs and their subsequent performance with respect to calcification opacification. Hydrophilic IOL with water content of 18% by weight, were coated with graphene oxide (GO) by equilibration with GO suspensions in water. The concentrations of the suspensions ranged 1x10-4 to 20x10-4 % w/v. The GO suspensions were equilibrated with the IOLs for 5 days at constant temperature, 37°C, rotated in 30 mL tubes end over end. This treatment, resulted in the formation of a uniform coating of GO on the IOLs verified by scanning electron microscopy (SEM) and other physicochemical methods. The contact angle of the GO coated IOLs decreased significantly in comparison with the uncoated. The GO-coated IOLs exhibited higher tendency to calcify in supersaturated solutions simulating aqueous humor (SAH). The growth rate of hydroxyapatite (Ca5(PO4)3OH, HAP) on GO-coated IOLs was higher, in comparison with the respective untreated IOLs. The conversion of the GO coating by reduction with phenyl hydrazine resulted in the formation of reduced graphene (rGO) surface film, identified by Raman and XPS spectroscopy. of the rGO film was hydrophobic (contact angle 100 o) and did not calcify in supersaturated calcium phosphate solutions.

  • Open Access

    Biological Mineralization of Hydrophilic Intraocular Lenses

    by Petros G. Koutsoukos, Panagiota D. Natsi, Sotirios P. Gartaganis, Panos S. Gartaganis

    Biomaterials calcify upon implantation in contact with biological fluids, which are supersaturated with respect to more than one crystalline phase of calcium phosphate. The implantation of intraocular lenses (IOLs) for cataract treatment has been hailed as a major advance. Hydrophilic acrylic IOLs, made of Poly(2-hydroxyethyl methacrylate) (PHEMA), upon contact with aqueous humor, exhibit significant incidence of opacification, due to the formation of calcium phosphate crystals, mainly hydroxyapatite (Ca5(PO4)3OH, HAP) on the surface or in their interior. The aqueous humor is supersaturated with respect to HAP. Clinical findings were duplicated by laboratory experiments through the development of appropriate experimental models which included batch reactors, well stirred operating at constant supersaturation (CCR) and reactors simulating anterior eye chamber (ECSR). In both CCR and ECSR, simulated aqueous humor was used. In ECSR the flow rate was the same as in the eye chamber (2.5 mL per 24 h). HAP formed both on the surface and inside the IOLs tested. Induction times preceding the crystallization of HAP on the surface of the IOLs and crystal growth rates were measured. Surface hydroxyl ionized groups favored the development of locally high supersaturation by surface complexation. In the interior of the IOLs, HAP formed by the diffusion of the calcium and phosphate ions inside the polymeric matrix.


  • Calcification of Hydrophilic Acrylic Intraocular Lenses With a Hydrophobic Surface: Laboratory Analysis of 6 Cases

    by Sotirios P. Gartaganis, Philipp Prahs, Eftichia D. Lazari, Panos S. Gartaganis, Horst Helbig, Petros G. Koutsoukos


  • Open Access

    Lysyl oxidase-like 1 polymorphisms in a southwestern Greek cataract population with pseudoexfoliation syndrome

    by Alexios Panoutsopoulos, Vassiliki S Gartaganis, Marios P Giannakopoulos, Panos D Goumas, Evangelos D Anastassiou, Sotirios P Gartaganis

    Purpose: The aim of this study was to determine the possible association of rs1048661 and rs3825942 single nucleotide polymorphisms (SNPs) in the lysyl oxidase-like 1 (LOXL1) gene of cataract patients from southwestern Greece with pseudoexfoliation (PEX) syndrome. Patients and methods: Ninety-three patients with PEX syndrome and 74 without PEX syndrome were recruited with the principal diagnosis being cataract. LOXL1 SNPs, rs1048661 and rs3825942, were genotyped by using polymerase chain reaction. Results: The G allele of rs1048661 was found in 96.7% in the PEX group as compared to 80.5% of non-PEX alleles (P=19×10-4; Odds ratio [OR] =5.37; 95% confidence interval [CI] =1.68–17.12). Similarly, the G allele of rs3825942 was found in 72.1% of the PEX group as compared to 41.8% of non-PEX alleles (P=4×10-5; OR =3.78; 95% CI =1.98–7.23). The T and A allele frequencies of rs1048661 and rs3825942, respectively, were underrepresented in the PEX group patients as compared to non-PEX group. Conclusion: Our data confirm previously reported association between LOXL1 polymorphisms and PEX syndrome in a southwestern Greek population. A significant association was found for the G allele of rs1048661 and rs3825942 demonstrating that the GG haplotype is a high-risk factor for the development of PEX syndrome.


  • Open Access

    Pseudoexfoliation syndrome and cardiovascular diseases

    by Georgios K Andrikopoulos, Dimitrios K Alexopoulos, Sotirios P Gartaganis

    Pseudoexfoliation (PEX) syndrome is a well-recognized late-onset disease caused by a generalized fibrillopathy. It is linked to a broad spectrum of ocular complications including glaucoma and perioperative problems during cataract surgery. Apart from the long-known intraocular manifestations, PEX deposits have been found in a variety of extraocular locations and they appear to represent a systemic process associated with increased cardiovascular and cerebrovascular morbidity. However, as published results are inconsistent, the clinical significance of the extraocular PEX deposits remains controversial. Identification of PEX deposits in the heart and the vessel wall, epidemiologic studies, as well as, similarities in pathogenetic mechanisms have led to the hypothesis of a possible relation between fibrillar material and cardiovascular disease. Recent studies suggest that PEX syndrome is frequently linked to impaired heart and blood vessels function. Systemic and ocular blood flow changes, altered parasympathetic vascular control and baroreflex sensitivity, increased vascular resistance and decreased blood flow velocity, arterial endothelial dysfunction, high levels of plasma homocysteine and arterial hypertension have all been demonstrated in PEX subjects. Common features in the pathogenesis of both atherosclerosis and PEX, like oxidative stress and inflammation and a possible higher frequency of abdominal aorta aneurysm in PEX patients, could imply that these grey-white deposits and cardiovascular disorders are related or reflect different manifestations of the same process.


  • Opacification of Hydrophilic Acrylic Intraocular Lens Attributable to Calcification: Investigation on Mechanism

    by Sotirios P. Gartaganis, Dimitra G. Kanellopoulou, Ephigenia K. Mela, Vassiliki S. Panteli, Petros G. Koutsoukos


  • Pseudoexfoliation syndrome prevalence in Greek patients with cataract and its association to glaucoma and coronary artery disease

    by G K Andrikopoulos, E K Mela, C D Georgakopoulos, G E Papadopoulos, A N Damelou, D K Alexopoulos, S P Gartaganis

    Purpose Methods Results Conclusions


  • Evidence for oxidative stress in lens epithelial cells in pseudoexfoliation syndrome

    by S P Gartaganis, N E Patsoukis, D K Nikolopoulos, C D Georgiou

    Purpose Methods Results Conclusion


  • Glutathione and Lipid Peroxide Changes in Pseudoexfoliation Syndrome

    by S. P. Gartaganis, C. D. Georgakopoulos, N. E. Patsoukis, S. S. Gotsis, V. S. Gartaganis, C. D. Georgiou

    Purpose:To investigate the oxidative status of the aqueous humor of patients with pseudoexfoliation (PEX) syndrome. Methods: Aqueous humor samples obtained during cataract surgery of patients with PEX syndrome and normal age-matched control subjects were examined for changes in the levels of glutathione (GSH), glutathione disulfide (GSSG), and TBA reactive species (TBARS), products of lipid peroxidation. GSH, GSSG, and TBARS were determined by specific fluorescent assays. Results: Compared to normal controls, PEX syndrome aqueous humor samples showed a decrease of up to 28% of GSH concentration, and GSSG was increased up to 23%. The ratio of GSH/GSSG was 1.7-fold decreased in PEX syndrome samples. TBARS levels were increased by 100% in the PEX aqueous humor samples as compared to the controls. Conclusions: High levels of GSSG and TBARS indicate high oxidative stress, as well as the decrease in the ratio of GSH/GSSG. Our findings suggest a role for oxidation stress in the pathogenesis and the progression of PEX syndrome.