Naoyoshi Egashira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Naoyoshi Egashira has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Yoshiharu Mitoma
Department of Environmental Sciences, Faculty of Life and Environmental Sciences, Prefectural University of Hiroshima, Shobara, Japan
3 shared publicationsEmi Hifumi
Department of Environmental Sciences, Faculty of Life and Environmental Sciences, Prefectural University of Hiroshima, Shobara-shi, Hiroshima, Japan, Research Center for Applied Medical Engineering, Oita University, Oita-shi, Oita, 870-1192, Japan, CREST, Japan Science and Technology Agency (JST), Kawaguchi-shi, Saitama 332-0012, Japan, and Department of Applied Chemistry, Faculty of Engineering, Oita University, Oita-shi, Oita, 870-1192, Japan
1 shared publication- Emi Hifumi
Oita University
1 shared publication Shin-Ichi Morita
Department of Environmental Sciences, Faculty of Life and Environmental Sciences, Prefectural University of Hiroshima, Shobara-shi, Hiroshima, Japan, Research Center for Applied Medical Engineering, Oita University, Oita-shi, Oita, 870-1192, Japan, CREST, Japan Science and Technology Agency (JST), Kawaguchi-shi, Saitama 332-0012, Japan, and Department of Applied Chemistry, Faculty of Engineering, Oita University, Oita-shi, Oita, 870-1192, Japan
1 shared publicationTaizo Uda
CREST, Japan Science and Technology Agency (JST)
1 shared publication- Taizo Uda
Oita University
1 shared publication
Latest Publications
- 12 May 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (22) , 5963-5971
Detection of influenza virus by a biosensor based on the method combining electrochemiluminescence on binary SAMs modified Au electrode with an immunoliposome encapsulating Ru (II) complex
Recently, point of care testing (POCT) used for diagnosis of influenza infection has a problem showing false negative diagnosis because of the low sensitivity. We would like to report detection of influenza virus A (H1N1) by an immunosensor based on electrochemiluminescence (ECL) that uses an immunoliposome encapsulating tris(2,2′-bipyridyl)ruthenium(II) complex. By using the sensor, we could detect the virus that competed with hemagglutinin (HA) peptide immobilized on self-assembled monolayers (SAMs) in immunoreaction of the antibody bound on the surface of liposome. The HA peptide was 19 mer (TGLRNGITNKVNSVIEKAA). We demonstrated great improvement of sensitivity and accuracy by introducing binary SAMs instead of mono SAMs. The binary SAMs was prepared from 3,3′-dithiodipropionic acid and 1-hexanethiol. Use of the binary SAMs enabled to increase the SAMs coverage on Au electrode; the fact was confirmed by observation of the cathodic desorption currents. By using such an electrode, first the detection method of BSA was optimized to lower ECL background signal. Then we applied the method to the detection of influenza virus. We could successfully detect the virus with higher sensitivity compared with that by POCT and ELISA. The detection range was from a concentration of 2.7 × 102 to 2.7 × 103 PFU/mL.
- 12 May 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (22) , 5963-5971
Detection of influenza virus by a biosensor based on the method combining electrochemiluminescence on binary SAMs modified Au electrode with an immunoliposome encapsulating Ru (II) complex
Recently, point of care testing (POCT) used for diagnosis of influenza infection has a problem showing false negative diagnosis because of the low sensitivity. We would like to report detection of influenza virus A (H1N1) by an immunosensor based on electrochemiluminescence (ECL) that uses an immunoliposome encapsulating tris(2,2′-bipyridyl)ruthenium(II) complex. By using the sensor, we could detect the virus that competed with hemagglutinin (HA) peptide immobilized on self-assembled monolayers (SAMs) in immunoreaction of the antibody bound on the surface of liposome. The HA peptide was 19 mer (TGLRNGITNKVNSVIEKAA). We demonstrated great improvement of sensitivity and accuracy by introducing binary SAMs instead of mono SAMs. The binary SAMs was prepared from 3,3′-dithiodipropionic acid and 1-hexanethiol. Use of the binary SAMs enabled to increase the SAMs coverage on Au electrode; the fact was confirmed by observation of the cathodic desorption currents. By using such an electrode, first the detection method of BSA was optimized to lower ECL background signal. Then we applied the method to the detection of influenza virus. We could successfully detect the virus with higher sensitivity compared with that by POCT and ELISA. The detection range was from a concentration of 2.7 × 102 to 2.7 × 103 PFU/mL.
- Open Access
- 1 January 2010
- Published by Springer Nature in Analytical Sciences
- Vol. 26 (3) , 371-373
A Flow-through Electrochemiluminescence Sensor for Salt Stress on Rice Plants
Cultivation of rice plants (Koshihikari, IR4595 and IR28) in 250 mmol/L NaCl over 16 days provided interesting profiles of responses on a flow-through electrochemiluminescence (ECL) system with tris(2,2′-bipyridine)ruthenium complex. Although some time lags were noted among these rice plants, the increment in the ECL responses was clearly observed on the 11th day. The obtained ECL response profiles were consistent with the proline profiles obtained by HPLC. Such consistensy demonstrated that the present ECL system would find a utility as a useful sensor for salt stress on rice plants.
- 1 January 2010
- Published by Springer Nature in Analytical Sciences
- Vol. 26 (3) , 371-373
Open AccessA Flow-through Electrochemiluminescence Sensor for Salt Stress on Rice Plants
Cultivation of rice plants (Koshihikari, IR4595 and IR28) in 250 mmol/L NaCl over 16 days provided interesting profiles of responses on a flow-through electrochemiluminescence (ECL) system with tris(2,2′-bipyridine)ruthenium complex. Although some time lags were noted among these rice plants, the increment in the ECL responses was clearly observed on the 11th day. The obtained ECL response profiles were consistent with the proline profiles obtained by HPLC. Such consistensy demonstrated that the present ECL system would find a utility as a useful sensor for salt stress on rice plants.
- 30 April 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (11) , 4020-4025
Attomole Detection of Hemagglutinin Molecule of Influenza Virus by Combining an Electrochemiluminescence Sensor with an Immunoliposome That Encapsulates a Ru Complex
An immunoliposome (80 nm in diameter) encapsulating a Ru complex with two aminobutyl moieties was prepared to detect the presence of hemagglutinin molecules, which play an important role in influenza virus infection. The highly sensitive detection was accomplished by electrochemiluminescence (ECL) from the Ru complex adsorbed onto Au electrodes after competitive immunoreactions. This method clarified that the adsorption of the Ru complex onto the electrode was an important factor in obtaining high sensitivity. Optimization of the analytical conditions enabled determination of the hemagglutinin molecules of the influenza virus in the concentration range of 3 × 10−14 (6 × 10−19 mol/50 µL sample) to 2 × 10−12 g/mL. The sensitivity was far superior to that obtained by conventional ELISA as well as to that obtained by biosensors and reported thus far.
- 30 April 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (11) , 4020-4025
Attomole Detection of Hemagglutinin Molecule of Influenza Virus by Combining an Electrochemiluminescence Sensor with an Immunoliposome That Encapsulates a Ru Complex
An immunoliposome (80 nm in diameter) encapsulating a Ru complex with two aminobutyl moieties was prepared to detect the presence of hemagglutinin molecules, which play an important role in influenza virus infection. The highly sensitive detection was accomplished by electrochemiluminescence (ECL) from the Ru complex adsorbed onto Au electrodes after competitive immunoreactions. This method clarified that the adsorption of the Ru complex onto the electrode was an important factor in obtaining high sensitivity. Optimization of the analytical conditions enabled determination of the hemagglutinin molecules of the influenza virus in the concentration range of 3 × 10−14 (6 × 10−19 mol/50 µL sample) to 2 × 10−12 g/mL. The sensitivity was far superior to that obtained by conventional ELISA as well as to that obtained by biosensors and reported thus far.