O. S. Chernyshova
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
O. S. Chernyshova has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
N.N. Nemets
Ukraine Research Institute of Nature Gas “UkrNDIgaz
3 shared publications- E. A. Reshetnyak
Kharkov Natl Univ, Svoboda Sq 4, UA-61022 Kharkov, Ukraine
2 shared publications - Elena A. Reshetnyak
V.N. Karazin National University
2 shared publications L.P. Loginova
2 shared publicationsV.M. Ostrovskaya
Federal Autonomous Enterprise "25 State research institute of the Ministry of Defence of Russian Federation
2 shared publicationsA.V. Panteleimonov
V.N. Karazin National University
1 shared publication
Latest Publications
- 1 January 2020
- Published by Ural Federal University in Аналитика и контроль
- Vol. 24 (2) , 124-132
Reflectometric and visual test determination of Pd(II) in objects of complex composition using the indicator paper
РЕФЛЕКТОМЕТРИЧЕСКОЕ И ВИЗУАЛЬНО-ТЕСТОВОЕ ОПРЕДЕЛЕНИЕ PD(II) В ОБЪЕКТАХ СЛОЖНОГО СОСТАВА С ИСПОЛЬЗОВАНИЕМ ИНДИКАТОРНОЙ БУМАГИ
- 1 January 2020
- Published by Ural Federal University in Аналитика и контроль
- Vol. 24 (2) , 124-132
Reflectometric and visual test determination of Pd(II) in objects of complex composition using the indicator paper
РЕФЛЕКТОМЕТРИЧЕСКОЕ И ВИЗУАЛЬНО-ТЕСТОВОЕ ОПРЕДЕЛЕНИЕ PD(II) В ОБЪЕКТАХ СЛОЖНОГО СОСТАВА С ИСПОЛЬЗОВАНИЕМ ИНДИКАТОРНОЙ БУМАГИ
- 1 January 2019
- Published by Taras Shevchenko National University of Kyiv in METHODS AND OBJECTS OF CHEMICAL ANALYSIS
- Vol. 14 (3) , 146-152
Visual Binary Testing Of Hydrogen Sulfide Dissolved In Return Underground Local-Water Of Oil And Gas Condensate Fields
In order to screen samples of return underground local-water of oil and gas condensate fields for the presence of dissolved hydrogen sulfide, it was proposed to use single comparison sample for visual binary testing of H2S. Two indicator reactions occurring in solutions were selected — the formation of a stabilized suspension of MnS and CdS. Suspensions prepared in the presence of borate buffer (pH 9.18) and gelatin (stabilizer) are stable during the twenty four hours; a difference in the turbidity of suspensions can be observed near the normalized concentration of hydrogen sulfide (сlim = 15 mg L-1). When establishing the concentration of H2S in the comparison samples, a statistical approach was applied; the estimated values of the threshold concentration of H2S (ccomp.) are less than the normalized level on the value which providing the risk of a false-negative test result not more than 5% - 11.6 mg L-1 for MnS and 13.4 mg L-1 for CdS. Preference was given to a test system based on a stabilized suspension of CdS, because for this reaction, a narrower interval of unreliability and the value of ccomp. is nearer to the value of the сlim. The correctness of the visual binary testing of H2S in the samples of the analyzed water was confirmed by spectrophotometric method with p-phenylenediamine.
- 1 January 2019
- Published by Taras Shevchenko National University of Kyiv in METHODS AND OBJECTS OF CHEMICAL ANALYSIS
- Vol. 14 (3) , 146-152
Visual Binary Testing Of Hydrogen Sulfide Dissolved In Return Underground Local-Water Of Oil And Gas Condensate Fields
In order to screen samples of return underground local-water of oil and gas condensate fields for the presence of dissolved hydrogen sulfide, it was proposed to use single comparison sample for visual binary testing of H2S. Two indicator reactions occurring in solutions were selected — the formation of a stabilized suspension of MnS and CdS. Suspensions prepared in the presence of borate buffer (pH 9.18) and gelatin (stabilizer) are stable during the twenty four hours; a difference in the turbidity of suspensions can be observed near the normalized concentration of hydrogen sulfide (сlim = 15 mg L-1). When establishing the concentration of H2S in the comparison samples, a statistical approach was applied; the estimated values of the threshold concentration of H2S (ccomp.) are less than the normalized level on the value which providing the risk of a false-negative test result not more than 5% - 11.6 mg L-1 for MnS and 13.4 mg L-1 for CdS. Preference was given to a test system based on a stabilized suspension of CdS, because for this reaction, a narrower interval of unreliability and the value of ccomp. is nearer to the value of the сlim. The correctness of the visual binary testing of H2S in the samples of the analyzed water was confirmed by spectrophotometric method with p-phenylenediamine.
- 1 January 2019
- Published by Taras Shevchenko National University of Kyiv in METHODS AND OBJECTS OF CHEMICAL ANALYSIS
- Vol. 14 (2) , 73-78
Value Of The Index Of Chemical Oxygen Demand As Measure Of The Methanol Content In Return Underground Local-Water Of Oil And Gas Condensate Fields
The method of the methanol content control in samples of return underground local-water of oil and gas condensate fields is described. The determination is based on a preliminary estimation of the chemical oxygen demand index, using an accelerated technique with potentiometric redox titration of potassium dichromate excess. On water-methanol solutions of known composition using the “added-found” method, it was proved that under the conditions of the chosen procedure, the methanol is completely oxidized; the value of the relative standard deviation of the determination results does not exceed 3 %. The interfering influence of the components of highly mineralized water samples on the integral assessment of chemical oxygen demand was studied. The accuracy of the determination of methanol in real water samples is proved by the method of standard additives.
- 1 January 2019
- Published by Taras Shevchenko National University of Kyiv in METHODS AND OBJECTS OF CHEMICAL ANALYSIS
- Vol. 14 (2) , 73-78
Value Of The Index Of Chemical Oxygen Demand As Measure Of The Methanol Content In Return Underground Local-Water Of Oil And Gas Condensate Fields
The method of the methanol content control in samples of return underground local-water of oil and gas condensate fields is described. The determination is based on a preliminary estimation of the chemical oxygen demand index, using an accelerated technique with potentiometric redox titration of potassium dichromate excess. On water-methanol solutions of known composition using the “added-found” method, it was proved that under the conditions of the chosen procedure, the methanol is completely oxidized; the value of the relative standard deviation of the determination results does not exceed 3 %. The interfering influence of the components of highly mineralized water samples on the integral assessment of chemical oxygen demand was studied. The accuracy of the determination of methanol in real water samples is proved by the method of standard additives.
- 27 September 2016
- Published by Pleiades Publishing Ltd in Colloid Journal
- Vol. 78 (5) , 647-651
Premicellar aggregation in water–salt solutions of sodium alkyl sulfonates and dodecyl sulfate
- 27 September 2016
- Published by Pleiades Publishing Ltd in Colloid Journal
- Vol. 78 (5) , 647-651
Premicellar aggregation in water–salt solutions of sodium alkyl sulfonates and dodecyl sulfate
- 1 May 2000
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 85 (3) , 351-359
The effect of surfactant micelle media on the copper(II) and camium(II) complex formation with some ligands
- 1 May 2000
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 85 (3) , 351-359
The effect of surfactant micelle media on the copper(II) and camium(II) complex formation with some ligands