Rüdiger Schulz-Wendtland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Rüdiger Schulz-Wendtland has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
W. Bautz
7 shared publicationsK.-P. Hermann
Universitätsmedizin Göttingen
6 shared publicationsC. Böhner
5 shared publicationsE. Wenkel
Universitätsklinikum Erlangen (University Hospital in Erlangen), Department of Radiology, Gynaecological Radiology, Erlangen
5 shared publicationsB. Adamietz
Universitätsklinikum Erlangen (University Hospital in Erlangen), Department of Radiology, Gynaecological Radiology, Erlangen
4 shared publications- Evelyn Wenkel
Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany
4 shared publications
Latest Publications
- 22 December 2011
- Published by Georg Thieme Verlag KG in Geburtshilfe und Frauenheilkunde
- Vol. 71 (12) , 1080-1084
Use of Tomosynthesis in Intraoperative Digital Specimen Radiography – Is a Reduction of Breast Re-excision Rates Possible?
Aim: A prospective clinical study was done to see whether it is possible to reduce the rate of re-excisions using digital breast tomosynthesis (DBT) compared commercial FFDM. Material and Method: Between 1/2011 and 5/2011 we diagnosed an invasive breast cancer (BI-RADS 5) in 100 patients. After histological verification we performed breast-conserving therapy with intraoperative imaging using one of 2 different systems: 1. Tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, Tungsten source, focus 0.1 mm, resolution 85 µm, pixel pitch, 8 l/mm, range: 50°, 25 projections, time for scanning > 20 s, geometry: same scanning scope, reconstruction: filtered back projection; or 2. Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm, pixel pitch, 8 l/mm as the standard. The 100 radiograms obtained with both systems were prospectively shown on a monitor to 3 radiologists. Results: Out of a total of 100 patients with histologically proven breast cancer (BI-RADS 6) no re-excision was necessary in 78 patients. A retrospective analysis (n = 22) demonstrated an increase in sensitivity of tomosynthesis compared to the Inspiration™ at a magnification of 1.0 : 1.0 of 8 % (p < 0.05), i.e., in 8 patients re-excision would not have been necessary with tomosynthesis. Conclusion: Tomosynthesis has a significant higher sensitivity (p < 0.05) compared with a commercial FFDM system. Studies with higher numbers of patients will be necessary to evaluate this method. Ziel: Prospektive Untersuchung, ob mithilfe der digitalen Brusttomosynthese (DBT) im Vergleich mit einem herkömmlichen FFDM-System eine Senkung der Rate an Reexzisionen möglich ist. Material und Methode: In der Zeit von 1/2011 bis 5/2011 wurde bei 100 Patientinnen ein invasives Mammakarzinom (BI-RADS 5) diagnostiziert. Nach histologischer Sicherung erfolgte die brusterhaltende Therapie mit intraoperativem Präparateradiogramm mit 2 unterschiedlichen Systemen: 1. Tomosynthese (Siemens, Erlangen, Deutschland), amorphes Selen, W-Anode, Fokus 0,1 mm, Ortsauflösung 85 µm, Pixelpitch, 8 l/mm, Winkelbereich 50°, 25 Projektionen, Scandauer > 20 s, Geometrie: gleichförmige Abtastung, Rekonstruktion: gefilterte Rückprojektion und 2. Inspiration™ (Siemens, Erlangen, Deutschland), amorphes Selen, W-Anode, Fokus 0,1 mm, Ortsauflösung 85 µm, Pixelpitch, 8 l/mm als Standard. Die jeweils 100 Präparateradiogramme wurden prospektiv 3 Radiologen auf einem Befundungsmonitor präsentiert. Ergebnisse: Bei den 100 Patientinnen mit histologisch gesichertem Mammakarzinom (BI-RADS 6) war bei 78 Patientinnen nach erfolgter brusterhaltender Therapie keine weitere operative Therapie (Reexzision) indiziert. Die retrospektive Analyse (n = 22) ergab eine Steigerung der Sensitivität zwischen Tomosynthese und Inspiration™ bei einer Vergrößerung von 1,0 : 1,0 von 8 % (p < 0,05), d. h. bei 8 Patientinnen wäre mit der Tomosynthese eine Reexzision nicht notwendig gewesen. Schlussfolgerung: Die Tomosynthese zur Präparateradiografie erreicht signifikant (p < 0,05) eine bessere Sensitivität im Vergleich zu einem FFDM-System mit herkömmlichem Detektor. Studien mit größeren Zahlen sind notwendig zur weiteren Evaluierung der Methode.
- 22 December 2011
- Published by Georg Thieme Verlag KG in Geburtshilfe und Frauenheilkunde
- Vol. 71 (12) , 1080-1084
Use of Tomosynthesis in Intraoperative Digital Specimen Radiography – Is a Reduction of Breast Re-excision Rates Possible?
Aim: A prospective clinical study was done to see whether it is possible to reduce the rate of re-excisions using digital breast tomosynthesis (DBT) compared commercial FFDM. Material and Method: Between 1/2011 and 5/2011 we diagnosed an invasive breast cancer (BI-RADS 5) in 100 patients. After histological verification we performed breast-conserving therapy with intraoperative imaging using one of 2 different systems: 1. Tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, Tungsten source, focus 0.1 mm, resolution 85 µm, pixel pitch, 8 l/mm, range: 50°, 25 projections, time for scanning > 20 s, geometry: same scanning scope, reconstruction: filtered back projection; or 2. Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm, pixel pitch, 8 l/mm as the standard. The 100 radiograms obtained with both systems were prospectively shown on a monitor to 3 radiologists. Results: Out of a total of 100 patients with histologically proven breast cancer (BI-RADS 6) no re-excision was necessary in 78 patients. A retrospective analysis (n = 22) demonstrated an increase in sensitivity of tomosynthesis compared to the Inspiration™ at a magnification of 1.0 : 1.0 of 8 % (p < 0.05), i.e., in 8 patients re-excision would not have been necessary with tomosynthesis. Conclusion: Tomosynthesis has a significant higher sensitivity (p < 0.05) compared with a commercial FFDM system. Studies with higher numbers of patients will be necessary to evaluate this method. Ziel: Prospektive Untersuchung, ob mithilfe der digitalen Brusttomosynthese (DBT) im Vergleich mit einem herkömmlichen FFDM-System eine Senkung der Rate an Reexzisionen möglich ist. Material und Methode: In der Zeit von 1/2011 bis 5/2011 wurde bei 100 Patientinnen ein invasives Mammakarzinom (BI-RADS 5) diagnostiziert. Nach histologischer Sicherung erfolgte die brusterhaltende Therapie mit intraoperativem Präparateradiogramm mit 2 unterschiedlichen Systemen: 1. Tomosynthese (Siemens, Erlangen, Deutschland), amorphes Selen, W-Anode, Fokus 0,1 mm, Ortsauflösung 85 µm, Pixelpitch, 8 l/mm, Winkelbereich 50°, 25 Projektionen, Scandauer > 20 s, Geometrie: gleichförmige Abtastung, Rekonstruktion: gefilterte Rückprojektion und 2. Inspiration™ (Siemens, Erlangen, Deutschland), amorphes Selen, W-Anode, Fokus 0,1 mm, Ortsauflösung 85 µm, Pixelpitch, 8 l/mm als Standard. Die jeweils 100 Präparateradiogramme wurden prospektiv 3 Radiologen auf einem Befundungsmonitor präsentiert. Ergebnisse: Bei den 100 Patientinnen mit histologisch gesichertem Mammakarzinom (BI-RADS 6) war bei 78 Patientinnen nach erfolgter brusterhaltender Therapie keine weitere operative Therapie (Reexzision) indiziert. Die retrospektive Analyse (n = 22) ergab eine Steigerung der Sensitivität zwischen Tomosynthese und Inspiration™ bei einer Vergrößerung von 1,0 : 1,0 von 8 % (p < 0,05), d. h. bei 8 Patientinnen wäre mit der Tomosynthese eine Reexzision nicht notwendig gewesen. Schlussfolgerung: Die Tomosynthese zur Präparateradiografie erreicht signifikant (p < 0,05) eine bessere Sensitivität im Vergleich zu einem FFDM-System mit herkömmlichem Detektor. Studien mit größeren Zahlen sind notwendig zur weiteren Evaluierung der Methode.
- 12 November 2010
- Published by Springer Nature in Der Radiologe
- Vol. 51 (2) , 126-129
Vergleich der Dignitätsbestimmung von mammographischem Mikrokalk mit zwei Systemen zur digitalen Vollfeldmammographie unterschiedlicher Detektorauflösung
- 12 November 2010
- Published by Springer Nature in Der Radiologe
- Vol. 51 (2) , 126-129
Vergleich der Dignitätsbestimmung von mammographischem Mikrokalk mit zwei Systemen zur digitalen Vollfeldmammographie unterschiedlicher Detektorauflösung
- 12 November 2010
- Published by Springer Nature in Der Radiologe
- Vol. 51 (2) , 130-134
Erste Untersuchungen zur Detektion simulierter mammographischer Läsionen
- 12 November 2010
- Published by Springer Nature in Der Radiologe
- Vol. 51 (2) , 130-134
Erste Untersuchungen zur Detektion simulierter mammographischer Läsionen
- 13 April 2007
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 179 (5) , 487-491
Experimentelle Untersuchungen zur Dosisreduktion durch Optimierung der Strahlungsqualität bei digitaler Vollfeldmammografie mit einem Detektor auf Selenbasis
Ziel: Reduktion der Strahlenexposition bei adäquater Bildqualität durch Optimierung der Strahlungsqualität für ein neues System zur digitalen Vollfeldmammografie mit einem digitalen Bildempfangssystem aus amorphem Selen (a-Se). Material und Methoden: Die Untersuchungen wurden an dem digitalen Mammografiesystem NovationDR (Siemens, Erlangen) durchgeführt. Das System besitzt eine Bimetallanode mit einer Molybdän- und einer Wolframbahn und kann wahlweise mit einem Molybdän- oder einem Rhodiumfilter betrieben werden. Als Testobjekt diente das Wisconsin Mammographic Random Phantom Modell 152A (Radiation Measurements Inc.), von dem Aufnahmen in digitaler Technik mit Wolframanode und Rhodiumfilter bei unterschiedlichen Röhrenspannungen (26 - 35 kV) und Röhrenstrom-Zeit-Produkten (40 - 100 mAs) angefertigt und mit Aufnahmen in Molybdän/Molybdän-Technik verglichen wurden. Zur Quantifizierung der Bildqualität wurde die Detektionsrate der im Phantom eingebetteten simulierten Läsionen eingesetzt. Ergebnisse: Bei zunehmender Röhrenspannung nimmt die mittlere Parenchymdosis beim Arbeiten mit Belichtungsautomatik, d. h. bei gleich bleibender Detektordosis signifikant ab. Gleichzeitig geht jedoch auch die Bildqualität, d. h. die Detektionsrate deutlich zurück (26 kV, 1 mGy, 95,1 % ; 35 kV, 0,7 mGy, 82,7 %). Als guter Kompromiss aus diagnostisch erforderlicher Bildqualität und geringstmöglicher Strahlenexposition wurden 28 kV und 60 mAs für eine Bildgebung mit Wolfram/Rhodium-Anoden/Filter-Kombination ausgewählt. Eine weitere Veränderung des Röhrenstrom-Zeit-Produktes erwies sich als nicht sinnvoll, da bereits eine 10 %ige Verringerung einen signifikanten Rückgang in der Detektionsrate zur Folge hatte. Andererseits bewirkte selbst eine ca. 65 %ige Erhöhung der Strahlenexposition nur eine ca. 2 %ige Verbesserung der Detektionsrate. Schlussfolgerung: Die Ergebnisse dieser Phantomstudie deuten an, dass durch den regelhaften Einsatz der Wolframanode in Kombination mit einem Rhodiumfilter bei der digitalen Vollfeldmammografie mit einem a-Se-Detektor gegenüber der Molybdän/Molybdän-Anoden/Filter-Kombination eine Reduktion der mittleren Parenchymdosis von bis zu 30 % ohne Verlust der diagnostischen Bildqualität zu erreichen ist. Purpose: Reduction of radiation exposure at an adequate image quality by optimizing the radiation quality for a new system of full-field digital mammography using a digital detector (a-Se). Materials and Methods: The investigations were performed using a digital mammography system Novation™ (Siemens, Erlangen). The system was constructed with a bimetal anode (molybdenum and tungsten) and the possibility of changing the filter (molybdenum/rhodium). The test object was the Wisconsin Mammography Random Phantom Model 152 A (Radiation Measurements Inc.) of which images were acquired using the digital technique with the tungsten anode and rhodium filter at different tube voltages (26 - 35 kV) and tube loads (40 - 100 mAs) and compared to images in the molybdan/molybdan molybdenum/molybdenum technique. To quantify the image quality, we used the detection rate of the simulated lesions in the phantom. Results: Increasing the tube voltage significantly decreases the average glandular dose when using AEC (Automatic Exposure Control), i. e., constant detector dose. At the same time, the image quality decreases significantly with respect to the detection rate (26 kV, 1 mGy, 95.1 %; 35 kV, 0.7 mGy, 82.7 %). As a good compromise between the necessary diagnostic image quality and the lowest dose exposition, 28 kV and 60 mAs were selected for imaging with the tungsten/rhodium anode/filter combination. A further change to the tube load did not make sense because a decrease of 10 % resulted in a significant decrease in the detection rate while only a 2 % increase in detection rate was achieved for a 65 % increase in radiation exposure. Conclusion: The results of this phantom study demonstrate that the routine use of the tungsten anode in combination with a rhodium filter for full-field digital mammography with an a-Se detector in contrast to a molybdan/molybdan molybdenum/molybdenum anode/filter combination results in a reduction of the average glandular dose of up to 30 % without loss of diagnostic image quality.
- 13 April 2007
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 179 (5) , 487-491
Experimentelle Untersuchungen zur Dosisreduktion durch Optimierung der Strahlungsqualität bei digitaler Vollfeldmammografie mit einem Detektor auf Selenbasis
Ziel: Reduktion der Strahlenexposition bei adäquater Bildqualität durch Optimierung der Strahlungsqualität für ein neues System zur digitalen Vollfeldmammografie mit einem digitalen Bildempfangssystem aus amorphem Selen (a-Se). Material und Methoden: Die Untersuchungen wurden an dem digitalen Mammografiesystem NovationDR (Siemens, Erlangen) durchgeführt. Das System besitzt eine Bimetallanode mit einer Molybdän- und einer Wolframbahn und kann wahlweise mit einem Molybdän- oder einem Rhodiumfilter betrieben werden. Als Testobjekt diente das Wisconsin Mammographic Random Phantom Modell 152A (Radiation Measurements Inc.), von dem Aufnahmen in digitaler Technik mit Wolframanode und Rhodiumfilter bei unterschiedlichen Röhrenspannungen (26 - 35 kV) und Röhrenstrom-Zeit-Produkten (40 - 100 mAs) angefertigt und mit Aufnahmen in Molybdän/Molybdän-Technik verglichen wurden. Zur Quantifizierung der Bildqualität wurde die Detektionsrate der im Phantom eingebetteten simulierten Läsionen eingesetzt. Ergebnisse: Bei zunehmender Röhrenspannung nimmt die mittlere Parenchymdosis beim Arbeiten mit Belichtungsautomatik, d. h. bei gleich bleibender Detektordosis signifikant ab. Gleichzeitig geht jedoch auch die Bildqualität, d. h. die Detektionsrate deutlich zurück (26 kV, 1 mGy, 95,1 % ; 35 kV, 0,7 mGy, 82,7 %). Als guter Kompromiss aus diagnostisch erforderlicher Bildqualität und geringstmöglicher Strahlenexposition wurden 28 kV und 60 mAs für eine Bildgebung mit Wolfram/Rhodium-Anoden/Filter-Kombination ausgewählt. Eine weitere Veränderung des Röhrenstrom-Zeit-Produktes erwies sich als nicht sinnvoll, da bereits eine 10 %ige Verringerung einen signifikanten Rückgang in der Detektionsrate zur Folge hatte. Andererseits bewirkte selbst eine ca. 65 %ige Erhöhung der Strahlenexposition nur eine ca. 2 %ige Verbesserung der Detektionsrate. Schlussfolgerung: Die Ergebnisse dieser Phantomstudie deuten an, dass durch den regelhaften Einsatz der Wolframanode in Kombination mit einem Rhodiumfilter bei der digitalen Vollfeldmammografie mit einem a-Se-Detektor gegenüber der Molybdän/Molybdän-Anoden/Filter-Kombination eine Reduktion der mittleren Parenchymdosis von bis zu 30 % ohne Verlust der diagnostischen Bildqualität zu erreichen ist. Purpose: Reduction of radiation exposure at an adequate image quality by optimizing the radiation quality for a new system of full-field digital mammography using a digital detector (a-Se). Materials and Methods: The investigations were performed using a digital mammography system Novation™ (Siemens, Erlangen). The system was constructed with a bimetal anode (molybdenum and tungsten) and the possibility of changing the filter (molybdenum/rhodium). The test object was the Wisconsin Mammography Random Phantom Model 152 A (Radiation Measurements Inc.) of which images were acquired using the digital technique with the tungsten anode and rhodium filter at different tube voltages (26 - 35 kV) and tube loads (40 - 100 mAs) and compared to images in the molybdan/molybdan molybdenum/molybdenum technique. To quantify the image quality, we used the detection rate of the simulated lesions in the phantom. Results: Increasing the tube voltage significantly decreases the average glandular dose when using AEC (Automatic Exposure Control), i. e., constant detector dose. At the same time, the image quality decreases significantly with respect to the detection rate (26 kV, 1 mGy, 95.1 %; 35 kV, 0.7 mGy, 82.7 %). As a good compromise between the necessary diagnostic image quality and the lowest dose exposition, 28 kV and 60 mAs were selected for imaging with the tungsten/rhodium anode/filter combination. A further change to the tube load did not make sense because a decrease of 10 % resulted in a significant decrease in the detection rate while only a 2 % increase in detection rate was achieved for a 65 % increase in radiation exposure. Conclusion: The results of this phantom study demonstrate that the routine use of the tungsten anode in combination with a rhodium filter for full-field digital mammography with an a-Se detector in contrast to a molybdan/molybdan molybdenum/molybdenum anode/filter combination results in a reduction of the average glandular dose of up to 30 % without loss of diagnostic image quality.
- 13 April 2007
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 179 (5) , 492-496
Vergleich der klinischen Wertigkeit von Zielaufnahmen mit reduzierter Pixelgröße des Detektors und digitalem Monitorzooming bei der Beurteilung von Mikrokalzifikationen in der digitalen Mammografie
Ziel: Evaluierung der diagnostischen Wertigkeit mammografischer Präparateaufnahmen mit einem digitalen Bildempfangssystem mit veränderbarer Pixelgröße bzw. in unterschiedlicher Darstellung auf dem Monitor. Material und Methoden: Mit dem digitalen Mammografiesystem SenoScan (Fischer Imaging, Denver, USA) wurden 50 Exzisionspräparate mit Mikrokalzifikationen sowohl im Normalmodus (Pixelgröße 54 µm) als auch im Hochauflösungsmodus (Pixelgröße 27 µm) aufgenommen. Die resultierenden Radiogramme wurden auf einem Monitor in einer 1:1-Darstellung wiedergegeben. Die Aufnahmen im Normalmodus (Pixelgröße 54 µm) wurden zusätzlich auch in einer 2:1-Darstellung wiedergegeben. Insgesamt 5 Befunder mit unterschiedlicher mammografischer Erfahrung mussten anhand der unterschiedlichen Darstellungen die Dignität des Mikrokalkes beurteilen. Die Aufnahmen wurden ihnen in zufälliger Reihenfolge präsentiert. Die Befunde wurden anschließend mit den Ergebnissen der Histologie verglichen. Ergebnisse: Im Hochauflösungsmodus ergaben sich für die 5 Befunder im Mittel tendenziell bessere Ergebnisse als im Normalmodus, die Unterschiede waren jedoch nicht signifikant. Gegenüber einer Sensitivität von 80 % und einer Spezifität von 72 % (PPV = 74 %, NPV = 78 %) für den Normalmodus, erreichte der Hochauflösungsmodus eine Sensitivität von 86 % und eine Spezifität von 74 % (PPV = 77 %, NPV = 83 %). Der auf dem Monitor in einer 2:1-Darstellung wiedergegebene Normalmodus erreichte 84 bzw. 74 % (PPV = 76 %, NPV = 82 %). Schlussfolgerung: Der Hochauflösungsmodus erhöht die Sensitivität und Spezifität bei der Bewertung der Mikrokalzifikationen nicht signifikant. Ein tendenziell gleiches Ergebnis ist bereits durch eine 2:1-Darstellung, d. h. ein digitales Zoomen am Monitor erreichbar. Für die klinische Mammografie bedeutet dies, dass eine hochauflösende Zielaufnahme mit diesem System im Allgemeinen keinen diagnostischen Gewinn bringt und daher aus strahlenhygienischen Gründen die Indikation für diese Zusatzaufnahme sehr eng gestellt werden muss. Purpose: Evaluation of the diagnostic value of breast specimen imaging with a digital mammographic system using a detector system with changeable pixel size compared to standard mode imaging in different monitor display modes. Materials and Methods: Using the digital mammographic system SenoScan (Fischer Imaging, Denver, USA), 50 diagnostic breast specimens with microcalcifications were visualized in both standard mode (pixel size 54 µm) and high resolution mode (pixel size 27 µm). The resulting radiographs were displayed 1:1 on a monitor. Standard mode images (pixel size 54 µm) were additionally displayed in a 2:1 mode. A total of 5 readers with different mammographic experience analyzed the type of the microcalcifications on the basis of the different display modes. The images were presented randomly. The findings were subsequently compared to the histology. Results: The high resolution mode yielded slightly but not significantly better results than the standard mode on average for all 5 readers. Compared to a sensitivity of 80 % and a specificity of 72 % (PPV = 74 %, NPV = 78 %) in the standard mode, the high resolution mode provided a sensitivity of 86 % and a specificity of 74 % (PPV = 77 %, NPV = 83 %). The standard mode images on a 2:1 monitor display yielded 84 % and 74 % (PPV = 76 %, NPV = 82 %). Conclusion: The high resolution mode did not significantly increase the sensitivity and specificity of the microcalcification reading. A similar improvement was achieved by the 2:1 display mode, i. e. digital monitor zooming. For the clinical situation this means that there is no diagnostic advantage from using a high resolution target view with this mammographic system.
- 13 April 2007
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 179 (5) , 492-496
Vergleich der klinischen Wertigkeit von Zielaufnahmen mit reduzierter Pixelgröße des Detektors und digitalem Monitorzooming bei der Beurteilung von Mikrokalzifikationen in der digitalen Mammografie
Ziel: Evaluierung der diagnostischen Wertigkeit mammografischer Präparateaufnahmen mit einem digitalen Bildempfangssystem mit veränderbarer Pixelgröße bzw. in unterschiedlicher Darstellung auf dem Monitor. Material und Methoden: Mit dem digitalen Mammografiesystem SenoScan (Fischer Imaging, Denver, USA) wurden 50 Exzisionspräparate mit Mikrokalzifikationen sowohl im Normalmodus (Pixelgröße 54 µm) als auch im Hochauflösungsmodus (Pixelgröße 27 µm) aufgenommen. Die resultierenden Radiogramme wurden auf einem Monitor in einer 1:1-Darstellung wiedergegeben. Die Aufnahmen im Normalmodus (Pixelgröße 54 µm) wurden zusätzlich auch in einer 2:1-Darstellung wiedergegeben. Insgesamt 5 Befunder mit unterschiedlicher mammografischer Erfahrung mussten anhand der unterschiedlichen Darstellungen die Dignität des Mikrokalkes beurteilen. Die Aufnahmen wurden ihnen in zufälliger Reihenfolge präsentiert. Die Befunde wurden anschließend mit den Ergebnissen der Histologie verglichen. Ergebnisse: Im Hochauflösungsmodus ergaben sich für die 5 Befunder im Mittel tendenziell bessere Ergebnisse als im Normalmodus, die Unterschiede waren jedoch nicht signifikant. Gegenüber einer Sensitivität von 80 % und einer Spezifität von 72 % (PPV = 74 %, NPV = 78 %) für den Normalmodus, erreichte der Hochauflösungsmodus eine Sensitivität von 86 % und eine Spezifität von 74 % (PPV = 77 %, NPV = 83 %). Der auf dem Monitor in einer 2:1-Darstellung wiedergegebene Normalmodus erreichte 84 bzw. 74 % (PPV = 76 %, NPV = 82 %). Schlussfolgerung: Der Hochauflösungsmodus erhöht die Sensitivität und Spezifität bei der Bewertung der Mikrokalzifikationen nicht signifikant. Ein tendenziell gleiches Ergebnis ist bereits durch eine 2:1-Darstellung, d. h. ein digitales Zoomen am Monitor erreichbar. Für die klinische Mammografie bedeutet dies, dass eine hochauflösende Zielaufnahme mit diesem System im Allgemeinen keinen diagnostischen Gewinn bringt und daher aus strahlenhygienischen Gründen die Indikation für diese Zusatzaufnahme sehr eng gestellt werden muss. Purpose: Evaluation of the diagnostic value of breast specimen imaging with a digital mammographic system using a detector system with changeable pixel size compared to standard mode imaging in different monitor display modes. Materials and Methods: Using the digital mammographic system SenoScan (Fischer Imaging, Denver, USA), 50 diagnostic breast specimens with microcalcifications were visualized in both standard mode (pixel size 54 µm) and high resolution mode (pixel size 27 µm). The resulting radiographs were displayed 1:1 on a monitor. Standard mode images (pixel size 54 µm) were additionally displayed in a 2:1 mode. A total of 5 readers with different mammographic experience analyzed the type of the microcalcifications on the basis of the different display modes. The images were presented randomly. The findings were subsequently compared to the histology. Results: The high resolution mode yielded slightly but not significantly better results than the standard mode on average for all 5 readers. Compared to a sensitivity of 80 % and a specificity of 72 % (PPV = 74 %, NPV = 78 %) in the standard mode, the high resolution mode provided a sensitivity of 86 % and a specificity of 74 % (PPV = 77 %, NPV = 83 %). The standard mode images on a 2:1 monitor display yielded 84 % and 74 % (PPV = 76 %, NPV = 82 %). Conclusion: The high resolution mode did not significantly increase the sensitivity and specificity of the microcalcification reading. A similar improvement was achieved by the 2:1 display mode, i. e. digital monitor zooming. For the clinical situation this means that there is no diagnostic advantage from using a high resolution target view with this mammographic system.
- 1 April 2007
- Published by Springer Nature in Der Radiologe
- Vol. 47 (4) , 359-370
Mammographiescreening
- 1 April 2007
- Published by Springer Nature in Der Radiologe
- Vol. 47 (4) , 359-370
Mammographiescreening
- 15 March 2007
- Published by Elsevier in Röntgenpraxis
- Vol. 56 (4) , 129-135
DR (a-Se) versus CR (DLR) – ist eine Verbesserung der Treffsicherheit möglich? Eine retrospektiv klinisch/histologische Analyse (n=100)
- 15 March 2007
- Published by Elsevier in Röntgenpraxis
- Vol. 56 (4) , 129-135
DR (a-Se) versus CR (DLR) – ist eine Verbesserung der Treffsicherheit möglich? Eine retrospektiv klinisch/histologische Analyse (n=100)
- 21 October 2005
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 26 (05) , 411-414
Interventionelle Methoden in der Mammadiagnostik - Ein neues Mamma-Vakuumbiopsiesystem im täglichen klinischen Einsatz
Studienziel: Untersuchung der diagnostischen Sicherheit des neuen Mamma-Vakuumbiopsiesystems (VacuFlash®) (VF) im täglichen klinischen Einsatz. Methode: Im Zeitraum von April 2002 bis März 2003 wurde bei 75 Patientinnen mit Verdacht auf eine Läsion BI-RADS™ 5 (analog) eine sonographisch geführte Vakuumbiopsie mit dem neuen VacuFlash® System durchgeführt. Das Alter der Patientinnen betrug 31 bis 74 Jahre (Median: 51 Jahre), die Tumorgröße 8 mm bis 33 mm (Median: 14 mm). Es wurden fünf Gewebezylinder von jeder Läsion entnommen. Ergebnisse: In 69 der 75 Herdbefunde (entsprechend 92 %) wurde der Malignitätsverdacht bestätigt, bei 6 Läsionen (entsprechend 8 %) ergab sich sowohl stanzbioptisch als auch anschließend operativ eine benigne Histologie. Schlussfolgerung: Das neue Vakuumbiopsiesystem VacuFlash® ist technisch eine ausgereifte und applikable diagnostische Methode. Insbesondere hinsichtlich der Kosten muss sie mit der Hochgeschwindigkeitsstanzbiopsie, dem handgeführten Mammotome® als auch der offenen chirurgischen Biopsie verglichen werden - hier spricht noch vieles als Standard für die Hochgeschwindigkeitsstanzbiopsie bei der diagnostischen Abklärung von Läsionen. Aim: To evaluate the diagnostic potential of the new vacuum-assisted method VacuFlash® (VF) in clinical routine of breast diagnostics. Method: From april 2002 to march 2003, the new sonographically guided vacuum-assisted system VacuFlash® was used in 75 patients with a BI-RADS™ 5 lesion (analogue). The patients were aged between 31-75 yrs (median: 51 yrs), the size of the lesions measured 8-33 mm (median: 14 mm). 5 specimens were taken from each lesion. Results: In 69 of the 75 lesions (92 %, respectively), malignancy was confirmed. In 8 lesions (8 %, resp.), we found a benign histology, confirmed by consecutive surgery. Conclusion: The new vacuum-assisted device VacuFlash® is a technically perfected and applicable diagnostic method. Especially in the view of the cost it has to be compared with high-speed core cut biopsy, the hand-held Mammotome® system and open surgical biopsy. High-speed core cut biopsy seems to be the standard procedure in diagnostic percutaneous breast intervention to clarify sonographically detected breast lesions.
- 21 October 2005
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 26 (05) , 411-414
Interventionelle Methoden in der Mammadiagnostik - Ein neues Mamma-Vakuumbiopsiesystem im täglichen klinischen Einsatz
Studienziel: Untersuchung der diagnostischen Sicherheit des neuen Mamma-Vakuumbiopsiesystems (VacuFlash®) (VF) im täglichen klinischen Einsatz. Methode: Im Zeitraum von April 2002 bis März 2003 wurde bei 75 Patientinnen mit Verdacht auf eine Läsion BI-RADS™ 5 (analog) eine sonographisch geführte Vakuumbiopsie mit dem neuen VacuFlash® System durchgeführt. Das Alter der Patientinnen betrug 31 bis 74 Jahre (Median: 51 Jahre), die Tumorgröße 8 mm bis 33 mm (Median: 14 mm). Es wurden fünf Gewebezylinder von jeder Läsion entnommen. Ergebnisse: In 69 der 75 Herdbefunde (entsprechend 92 %) wurde der Malignitätsverdacht bestätigt, bei 6 Läsionen (entsprechend 8 %) ergab sich sowohl stanzbioptisch als auch anschließend operativ eine benigne Histologie. Schlussfolgerung: Das neue Vakuumbiopsiesystem VacuFlash® ist technisch eine ausgereifte und applikable diagnostische Methode. Insbesondere hinsichtlich der Kosten muss sie mit der Hochgeschwindigkeitsstanzbiopsie, dem handgeführten Mammotome® als auch der offenen chirurgischen Biopsie verglichen werden - hier spricht noch vieles als Standard für die Hochgeschwindigkeitsstanzbiopsie bei der diagnostischen Abklärung von Läsionen. Aim: To evaluate the diagnostic potential of the new vacuum-assisted method VacuFlash® (VF) in clinical routine of breast diagnostics. Method: From april 2002 to march 2003, the new sonographically guided vacuum-assisted system VacuFlash® was used in 75 patients with a BI-RADS™ 5 lesion (analogue). The patients were aged between 31-75 yrs (median: 51 yrs), the size of the lesions measured 8-33 mm (median: 14 mm). 5 specimens were taken from each lesion. Results: In 69 of the 75 lesions (92 %, respectively), malignancy was confirmed. In 8 lesions (8 %, resp.), we found a benign histology, confirmed by consecutive surgery. Conclusion: The new vacuum-assisted device VacuFlash® is a technically perfected and applicable diagnostic method. Especially in the view of the cost it has to be compared with high-speed core cut biopsy, the hand-held Mammotome® system and open surgical biopsy. High-speed core cut biopsy seems to be the standard procedure in diagnostic percutaneous breast intervention to clarify sonographically detected breast lesions.
- 10 June 2005
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 26 (03) , 209-215
Mamma-Sonographie mit 7,5 MHz versus 13 MHz: Ist eine Verbesserung der diagnostischen Sicherheit im Rahmen der komplementären Mammadiagnostik möglich?
Ziel: Komplementäre Untersuchungsverfahren in der Brustkrebsfrüherkennung sollen die diagnostische Treffsicherheit erhöhen und dadurch helfen, die Zahl unnötiger operativer Eingriffe an der Brust zu minimieren. Ziel der vorliegenden prospektiven, offenen Multizenterstudie war die Überprüfung, ob durch den Einsatz hochfrequenter Mammasonographie mit 13 MHz im Vergleich zur Standard-Mammasonographie mit 7,5 MHz eine höhere diagnostische Sicherheit erreicht werden kann. Methode: Zwischen Oktober 1996 und Dezember 1997 konnten an 4 beteiligten Zentren 810 Patientinnen zwischen 45 und 60 Jahren mit insgesamt 819 verdächtigen Mammaläsionen der Kategorien BI-RADS™ 4 bzw. 5 in die Studie eingeschlossen werden. Die standardisierte Mammasonographie erfolgte einheitlich mit dem Ultraschall-Diagnostiksystem AU4 IDEA der Fa. Esaote-Biomedica in Kenntnis der ebenfalls standardisiert erfassten klinischen Befunde und der Mammographie in 2 Standardebenen. Die Analyse der so erhobenen Daten und der korrelierenden histopathologischen Befunde erfolgte mittels deskriptiver Statistik auf der Basis einer Access-Datenbank (Version 2.0). Ergebnisse: Die histopathologische Evaluation erbrachte 435 benigne und 384 maligne Befunde inklusive In-situ-Karzinomen. Die Sensitivität und Spezifität der klinischen Untersuchung lagen insgesamt bei 71,1 % bzw. 88,9 %, der Mammographie bei 84,7 % bzw. 76,5 %, der Standardsonographie mit 7,5 MHz bei 82,6 % bzw. 80,8 % und der Hochfrequenzsonographie bei 13 MHz bei 87,2 % bzw. 78,4 %. Unter Berücksichtigung der Tumorgrößen zeigte die Mammographie die höchste Sensitivität bei der Erkennung prä-invasiver (DCIS) Karzinome. Die Hochfrequenz-Mammasonographie (13 MHz) ließ größenunabhängig eine höhere Treffsicherheit erkennen als die Standardsonographie bei 7,5 MHz. Die Steigerung der Sensitivität war mit 78 % versus 56 % insbesondere deutlich bei kleinen invasiven Mammakarzinomen (pT1a). Schlussfolgerungen: Aufgrund dieser Ergebnisse gehen wir davon aus, dass die Hochfrequenzsonographie insbesondere als additives bildgebendes Verfahren insbesondere bei kleinen Tumoren dazu beitragen kann, die diagnostische Sicherheit zu erhöhen und dadurch die Anzahl interventioneller Maßnahmen zu reduzieren. Aim: Complementary diagnostic methods in early diagnosis of breast cancer are used to increase diagnostic accuracy and minimize unnecessary invasive diagnostic procedures. Aim of the following prospective, open multicenter clinical study was to define the value of high-frequency breast ultrasound with 13 MHZ transducers compared to standard breast ultrasound with 7,5 MHz. Method: Data of 810 female patients, aged 45 to 60 years, with 819 suspicious breast lesions evaluated by four participating centres between October 1996 and December 1997. Standardised breast ultrasound was performed uniformly using a AU4 IDEA diagnostic ultrasound system by Esaote-Biomedica® in addition to a standardised procedure of clinical examination and standard-2view-mammography. Analysis of all aquired data and the correlating histopathological findings was done by means of descriptive statistics on the basis of an access datafile (Version 2.0). Results: The histopathological evaluation showed 435 benign and 384 malignant findings. Overall sensitivity and specificity of the clinical examination were 71,1 % and 88,9 % and for mammography 84,7 % and 76,5 %, respectively. Standard ultrasound with 7,5 MHz reached a sensitivity of 82,6 % and a specificity of 80,8 % high-frequency ultrasound with 13 MHz came to 87,2 % and 78,4 %, respectively. Regarding tumour size, mammography gave the highest sensitivity in detection of pre-invasive cancers (DCIS). High-frequency breast ultrasound (13 MHz) proved to have a higher diagnostic accuracy compared to standard breast ultrasound (7,5 MHz) regardless of tumour size. Sensitivity was especially improved in case of small invasive tumours (pT1a) with 78 % versus 56 %, respectively. Conclusions: We conclude that high-frequency ultrasound is a valueable additive tool especially in the diagnosis of small tumours, improving diagnostic safety and reducing unnecessary invasive diagnostic procedures.
- 10 June 2005
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 26 (03) , 209-215
Mamma-Sonographie mit 7,5 MHz versus 13 MHz: Ist eine Verbesserung der diagnostischen Sicherheit im Rahmen der komplementären Mammadiagnostik möglich?
Ziel: Komplementäre Untersuchungsverfahren in der Brustkrebsfrüherkennung sollen die diagnostische Treffsicherheit erhöhen und dadurch helfen, die Zahl unnötiger operativer Eingriffe an der Brust zu minimieren. Ziel der vorliegenden prospektiven, offenen Multizenterstudie war die Überprüfung, ob durch den Einsatz hochfrequenter Mammasonographie mit 13 MHz im Vergleich zur Standard-Mammasonographie mit 7,5 MHz eine höhere diagnostische Sicherheit erreicht werden kann. Methode: Zwischen Oktober 1996 und Dezember 1997 konnten an 4 beteiligten Zentren 810 Patientinnen zwischen 45 und 60 Jahren mit insgesamt 819 verdächtigen Mammaläsionen der Kategorien BI-RADS™ 4 bzw. 5 in die Studie eingeschlossen werden. Die standardisierte Mammasonographie erfolgte einheitlich mit dem Ultraschall-Diagnostiksystem AU4 IDEA der Fa. Esaote-Biomedica in Kenntnis der ebenfalls standardisiert erfassten klinischen Befunde und der Mammographie in 2 Standardebenen. Die Analyse der so erhobenen Daten und der korrelierenden histopathologischen Befunde erfolgte mittels deskriptiver Statistik auf der Basis einer Access-Datenbank (Version 2.0). Ergebnisse: Die histopathologische Evaluation erbrachte 435 benigne und 384 maligne Befunde inklusive In-situ-Karzinomen. Die Sensitivität und Spezifität der klinischen Untersuchung lagen insgesamt bei 71,1 % bzw. 88,9 %, der Mammographie bei 84,7 % bzw. 76,5 %, der Standardsonographie mit 7,5 MHz bei 82,6 % bzw. 80,8 % und der Hochfrequenzsonographie bei 13 MHz bei 87,2 % bzw. 78,4 %. Unter Berücksichtigung der Tumorgrößen zeigte die Mammographie die höchste Sensitivität bei der Erkennung prä-invasiver (DCIS) Karzinome. Die Hochfrequenz-Mammasonographie (13 MHz) ließ größenunabhängig eine höhere Treffsicherheit erkennen als die Standardsonographie bei 7,5 MHz. Die Steigerung der Sensitivität war mit 78 % versus 56 % insbesondere deutlich bei kleinen invasiven Mammakarzinomen (pT1a). Schlussfolgerungen: Aufgrund dieser Ergebnisse gehen wir davon aus, dass die Hochfrequenzsonographie insbesondere als additives bildgebendes Verfahren insbesondere bei kleinen Tumoren dazu beitragen kann, die diagnostische Sicherheit zu erhöhen und dadurch die Anzahl interventioneller Maßnahmen zu reduzieren. Aim: Complementary diagnostic methods in early diagnosis of breast cancer are used to increase diagnostic accuracy and minimize unnecessary invasive diagnostic procedures. Aim of the following prospective, open multicenter clinical study was to define the value of high-frequency breast ultrasound with 13 MHZ transducers compared to standard breast ultrasound with 7,5 MHz. Method: Data of 810 female patients, aged 45 to 60 years, with 819 suspicious breast lesions evaluated by four participating centres between October 1996 and December 1997. Standardised breast ultrasound was performed uniformly using a AU4 IDEA diagnostic ultrasound system by Esaote-Biomedica® in addition to a standardised procedure of clinical examination and standard-2view-mammography. Analysis of all aquired data and the correlating histopathological findings was done by means of descriptive statistics on the basis of an access datafile (Version 2.0). Results: The histopathological evaluation showed 435 benign and 384 malignant findings. Overall sensitivity and specificity of the clinical examination were 71,1 % and 88,9 % and for mammography 84,7 % and 76,5 %, respectively. Standard ultrasound with 7,5 MHz reached a sensitivity of 82,6 % and a specificity of 80,8 % high-frequency ultrasound with 13 MHz came to 87,2 % and 78,4 %, respectively. Regarding tumour size, mammography gave the highest sensitivity in detection of pre-invasive cancers (DCIS). High-frequency breast ultrasound (13 MHz) proved to have a higher diagnostic accuracy compared to standard breast ultrasound (7,5 MHz) regardless of tumour size. Sensitivity was especially improved in case of small invasive tumours (pT1a) with 78 % versus 56 %, respectively. Conclusions: We conclude that high-frequency ultrasound is a valueable additive tool especially in the diagnosis of small tumours, improving diagnostic safety and reducing unnecessary invasive diagnostic procedures.