Zhao-Lun Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhao-Lun Fang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Shi-Li Wang
Research Center for Analytical Sciences, Northeastern University, Shenyang 110004, PR China
2 shared publicationsJing Dai
Research Center for Analytical Sciences, Northeastern University, Shenyang, 110004, P. R. China
1 shared publicationQun Fang
Zhejiang University, Chemistry Department, Institute of Microanalytical Systems, Xixi Campus, 310028 Hangzhou, China
1 shared publicationYan-Xia Guan
Northeastern University
1 shared publicationZhang-Run Xu
Research Center for Analytical Sciences, Northeastern University, Box 332, 110004 Shenyang, China
1 shared publicationZhi-Yong Wu
Northeastern University
1 shared publication
Latest Publications
- 7 June 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (8) , 1747-1750
Integrating functional components into capillary electrophoresis systems using liquid-core waveguides
- 7 June 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (8) , 1747-1750
Integrating functional components into capillary electrophoresis systems using liquid-core waveguides
- 17 February 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 381 (4) , 807-808
Microfluidics in China
- 17 February 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 381 (4) , 807-808
Microfluidics in China
- 29 January 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 381 (4) , 839-843
Feature characterization of microfabricated microfluidic chips by PDMS replication and CCD imaging
- 29 January 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 381 (4) , 839-843
Feature characterization of microfabricated microfluidic chips by PDMS replication and CCD imaging
- 1 April 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 507 (1) , 129-135
Composite poly(dimethylsiloxane)/glass microfluidic system with an immobilized enzymatic particle-bed reactor and sequential sample injection for chemiluminescence determinations
- 1 April 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 507 (1) , 129-135
Composite poly(dimethylsiloxane)/glass microfluidic system with an immobilized enzymatic particle-bed reactor and sequential sample injection for chemiluminescence determinations
- 1 August 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 370 (8) , 978-983
Development of a low-cost microfluidic capillary-electrophoresis system coupled with flow-injection and sequential-injection sample introduction (review)
Microfabrication techniques used for the production of MEMS (micro electro-mechanical systems) have been successfully used to produce highly efficient microfluidic capillary electrophoresis chip systems. A limitation of this approach are the difficulties associated with the creation of the micrometer-sized structures in glass or other substrates, which currently involve specialized and expensive lithographic and etching processes. A further limitation is that hitherto most microfluidic chips are not designed for continuous introduction of a series of different samples, which limits the overall throughput of such systems. This article reviews the development of a microfluidic system for rapid CE separations, produced at a low cost of less than a dollar each, using equipment and materials readily available in the ordinary laboratory. Applications of the system, after coupling to flow-injection and/or sequential-injection sample introduction, for the determination of FITC- labeled amino acids by laser-induced fluorescence, trace metals by chemiluminescence, carbohydrates by amperometry, and inorganic and organic anions by indirect UV absorbance are exemplified to illustrate the performance and versatility of the microfluidic system.
- 1 August 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 370 (8) , 978-983
Development of a low-cost microfluidic capillary-electrophoresis system coupled with flow-injection and sequential-injection sample introduction (review)
Microfabrication techniques used for the production of MEMS (micro electro-mechanical systems) have been successfully used to produce highly efficient microfluidic capillary electrophoresis chip systems. A limitation of this approach are the difficulties associated with the creation of the micrometer-sized structures in glass or other substrates, which currently involve specialized and expensive lithographic and etching processes. A further limitation is that hitherto most microfluidic chips are not designed for continuous introduction of a series of different samples, which limits the overall throughput of such systems. This article reviews the development of a microfluidic system for rapid CE separations, produced at a low cost of less than a dollar each, using equipment and materials readily available in the ordinary laboratory. Applications of the system, after coupling to flow-injection and/or sequential-injection sample introduction, for the determination of FITC- labeled amino acids by laser-induced fluorescence, trace metals by chemiluminescence, carbohydrates by amperometry, and inorganic and organic anions by indirect UV absorbance are exemplified to illustrate the performance and versatility of the microfluidic system.