Masume Khodsuz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masume Khodsuz has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Mohammad Mirzaie
Department of Electrical and Computer Engineering Babol University of Technology Babol Iran
3 shared publications
Latest Publications
- Open Access
- 1 December 2015
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 9 (16) , 2501-2508
Monitoring and identification of metal–oxide surge arrester conditions using multi‐layer support vector machine
Metal–oxide surge arresters (MOSAs) are essential equipments for power system protection and devices from lightning and switching transient overvoltages. Therefore, their operating condition and diagnosis are very important. In this study, a multi‐layer support vector machine (SVM) classifier has been used for MOSA conditions monitoring based on experimental tests. Three features are extracted based on the test results for determining surge arresters operating conditions including clean virgin, ultraviolet (UV) aged clean surface, surface contaminations after and before UV housing ageing, and degraded varistors along active column. Then, the multi‐layer SVM classifier is trained with the training samples, which are extracted by the above data processing. Finally, the five fault types of surge arresters are identified by this classifier. The test results show that the classifier has an excellent performance on training speed and reliability which confirm the high applicability of introduced features for correct diagnostic of surge arresters conditions.
- 1 December 2015
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 9 (16) , 2501-2508
Open AccessMonitoring and identification of metal–oxide surge arrester conditions using multi‐layer support vector machine
Metal–oxide surge arresters (MOSAs) are essential equipments for power system protection and devices from lightning and switching transient overvoltages. Therefore, their operating condition and diagnosis are very important. In this study, a multi‐layer support vector machine (SVM) classifier has been used for MOSA conditions monitoring based on experimental tests. Three features are extracted based on the test results for determining surge arresters operating conditions including clean virgin, ultraviolet (UV) aged clean surface, surface contaminations after and before UV housing ageing, and degraded varistors along active column. Then, the multi‐layer SVM classifier is trained with the training samples, which are extracted by the above data processing. Finally, the five fault types of surge arresters are identified by this classifier. The test results show that the classifier has an excellent performance on training speed and reliability which confirm the high applicability of introduced features for correct diagnostic of surge arresters conditions.
- Open Access
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 9 (8) , 979-986
Evaluation of ultraviolet ageing, pollution and varistor degradation effects on harmonic contents of surge arrester leakage current
Metal‐oxide surge arresters are one of the most important equipments for power system protection against switching and lightning over‐voltages. Surge arresters leakage currents increase by the operating time. In this study, the important factors on leakage current variations such as surface contamination, ultraviolet ageing and varistor degradation have been studied. To accomplish this purpose, experimental tests have been performed on various polymer housed surge arresters. Fast Fourier transform analysis has been performed on measured leakage currents. Results show that ultraviolet radiation and varistor degradation affect resistive harmonic components, especially the third and fifth harmonics. Moreover, it is observed that surface contamination has influence on fundamental harmonic variation more than ultraviolet ageing. In addition, combination of ultraviolet radiation and pollution had more effect on leakage currents. The investigation and the discussion of the results can be used to easily analyse arresters condition leading to effective schedule maintenance.
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 9 (8) , 979-986
Open AccessEvaluation of ultraviolet ageing, pollution and varistor degradation effects on harmonic contents of surge arrester leakage current
Metal‐oxide surge arresters are one of the most important equipments for power system protection against switching and lightning over‐voltages. Surge arresters leakage currents increase by the operating time. In this study, the important factors on leakage current variations such as surface contamination, ultraviolet ageing and varistor degradation have been studied. To accomplish this purpose, experimental tests have been performed on various polymer housed surge arresters. Fast Fourier transform analysis has been performed on measured leakage currents. Results show that ultraviolet radiation and varistor degradation affect resistive harmonic components, especially the third and fifth harmonics. Moreover, it is observed that surface contamination has influence on fundamental harmonic variation more than ultraviolet ageing. In addition, combination of ultraviolet radiation and pollution had more effect on leakage currents. The investigation and the discussion of the results can be used to easily analyse arresters condition leading to effective schedule maintenance.
- 26 June 2015
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 97 (4) , 445-451
A Modified Time-Delay Addition Method to Extract Resistive Leakage Current of MOSA
- 26 June 2015
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 97 (4) , 445-451
A Modified Time-Delay Addition Method to Extract Resistive Leakage Current of MOSA