Isabel Mino-Rodriguez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Isabel Mino-Rodriguez has a total of 133 co-authors. Here are the top co-authors by number of shared publications:
- Marcel Schweiker
Healthy Living Spaces lab, Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
6 shared publications - Irene Martínez-Muñoz
Institute of Building Physics, Services, and Construction, Graz University of Technology
4 shared publications - Stephanie Gauthier
University of Southampton, Southampton, United Kingdom
4 shared publications Andreas Wagner
3 shared publications- Andreas Wagner
Karlsruhe Institute of Technology, Germany
3 shared publications - Ardeshir Mahdavi
Institute of Building Physics, Services, and Construction, Faculty of Civil Engineering Sciences, Graz University of Technology, Graz, Austria
3 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by Elsevier in SSRN Electronic Journal
Cross-domain effects of thermal and visual conditions on indoor environmental perception: a within-participant climate-chamber study
Occupants experience indoor environmental quality (IEQ) domains simultaneously, yet evidence for cross-domain effects between thermal and visual conditions remains inconsistent and often conflates sensation with evaluation constructs. This study examined corresponding-domain and cross-domain contrasts and interactions across nine subjective outcomes. In a controlled 2 × 2 repeated-measures experiment, 68 participants contributed 250 observations under Cool and Warm thermal conditions and Low and High daylight-transmittance conditions. Bayesian cumulative ordinal multilevel models adjusted for exposure stage, season, and participant-level effects. A contrast was considered supported when its 95% credible interval (CrI) excluded zero. Both manipulations produced the expected responses in their respective domains: High was perceived as brighter and more visually satisfactory than Low, while Warm was perceived as warmer and more thermally satisfactory than Cool. Outside the visual domain, no High-minus-Low contrast met the interval criterion. Warm-minus-Cool contrasts indicated lower freshness sensation (-2.31, 95% CrI [-3.07, -1.63]), air-quality satisfaction (-1.60 [-2.15, -1.08]), and acoustic-environment satisfaction (-0.46 [-0.90, -0.02]). Differences in visual responses, sound sensation, and overall satisfaction were inconclusive. No daylight-transmittance-by-thermal-condition interaction met the interval criterion, although uncertainty was too broad to conclude that interactions were absent or practically negligible. Because thermal condition was fixed to office, Warm-minus-Cool estimates may include residual between-room differences, particularly for acoustic satisfaction, as measured sound levels differed between offices. Under the investigated exposure ranges, daylight-transmittance effects were confined to the visual domain, whereas the thermal-condition/room contrast was associated most strongly with air-related responses.
- 19 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCross-domain effects of thermal and visual conditions on indoor environmental perception: a within-participant climate-chamber study
Occupants experience indoor environmental quality (IEQ) domains simultaneously, yet evidence for cross-domain effects between thermal and visual conditions remains inconsistent and often conflates sensation with evaluation constructs. This study examined corresponding-domain and cross-domain contrasts and interactions across nine subjective outcomes. In a controlled 2 × 2 repeated-measures experiment, 68 participants contributed 250 observations under Cool and Warm thermal conditions and Low and High daylight-transmittance conditions. Bayesian cumulative ordinal multilevel models adjusted for exposure stage, season, and participant-level effects. A contrast was considered supported when its 95% credible interval (CrI) excluded zero. Both manipulations produced the expected responses in their respective domains: High was perceived as brighter and more visually satisfactory than Low, while Warm was perceived as warmer and more thermally satisfactory than Cool. Outside the visual domain, no High-minus-Low contrast met the interval criterion. Warm-minus-Cool contrasts indicated lower freshness sensation (-2.31, 95% CrI [-3.07, -1.63]), air-quality satisfaction (-1.60 [-2.15, -1.08]), and acoustic-environment satisfaction (-0.46 [-0.90, -0.02]). Differences in visual responses, sound sensation, and overall satisfaction were inconclusive. No daylight-transmittance-by-thermal-condition interaction met the interval criterion, although uncertainty was too broad to conclude that interactions were absent or practically negligible. Because thermal condition was fixed to office, Warm-minus-Cool estimates may include residual between-room differences, particularly for acoustic satisfaction, as measured sound levels differed between offices. Under the investigated exposure ranges, daylight-transmittance effects were confined to the visual domain, whereas the thermal-condition/room contrast was associated most strongly with air-related responses.
- Open Access
- 8 September 2026
- Published by Elsevier in SSRN Electronic Journal
Modifying the Berkeley Local Thermal Sensation and Comfort Models Considering the Effect of Radiant Heat Flux
Radiant heating is a promising strategy for improving thermal comfort while reducing heating energy demand, but existing local thermal sensation and comfort models, including the Berkeley model, were developed mainly from convective data and have rarely been evaluated under localized radiant heating in indoor building environments. This study assessed and modified the existing Berkeley local thermal sensation and comfort models using experimental data from neutral conditions and localized radiant heating applied to different body parts across 459 experimental sessions, then validated the models using independent asymmetric and transient experiments. The Berkeley model showed substantial prediction errors under radiant heating, with local sensation and comfort mean absolute errors (MAE) reaching up to 2.42 and 1.89 scale units, respectively, with the largest deviations observed for the head (sensation) and lower leg (comfort). Across body parts, the modified models reduced MAE by up to 83% for sensation and up to 61% for comfort. Validation against independent asymmetric and transient experimental datasets confirmed the improvement, where MAE decreased from 1.12-1.18 to 0.83-0.84 for local sensation and from 1.10 to 0.82-0.88 for local comfort, with 70–97% of participants showing improvement. Improvements were observed for most body parts, and some regions showed only small differences. Overall, the results show that new local neutral setpoints and coefficients improve the prediction of local thermal sensation and comfort under radiant heating. The new coefficient sets provide a basis for the design and control of localized radiant heating systems that aim to maintain comfort while reducing building heating demand.
- 8 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessModifying the Berkeley Local Thermal Sensation and Comfort Models Considering the Effect of Radiant Heat Flux
Radiant heating is a promising strategy for improving thermal comfort while reducing heating energy demand, but existing local thermal sensation and comfort models, including the Berkeley model, were developed mainly from convective data and have rarely been evaluated under localized radiant heating in indoor building environments. This study assessed and modified the existing Berkeley local thermal sensation and comfort models using experimental data from neutral conditions and localized radiant heating applied to different body parts across 459 experimental sessions, then validated the models using independent asymmetric and transient experiments. The Berkeley model showed substantial prediction errors under radiant heating, with local sensation and comfort mean absolute errors (MAE) reaching up to 2.42 and 1.89 scale units, respectively, with the largest deviations observed for the head (sensation) and lower leg (comfort). Across body parts, the modified models reduced MAE by up to 83% for sensation and up to 61% for comfort. Validation against independent asymmetric and transient experimental datasets confirmed the improvement, where MAE decreased from 1.12-1.18 to 0.83-0.84 for local sensation and from 1.10 to 0.82-0.88 for local comfort, with 70–97% of participants showing improvement. Improvements were observed for most body parts, and some regions showed only small differences. Overall, the results show that new local neutral setpoints and coefficients improve the prediction of local thermal sensation and comfort under radiant heating. The new coefficient sets provide a basis for the design and control of localized radiant heating systems that aim to maintain comfort while reducing building heating demand.
- Open Access
- 18 March 2026
- Published by Elsevier in Building and Environment
- Vol. 297
Causal cross-modal effects between odor and temperature on occupants’ perception in a single-person office environment
- 18 March 2026
- Published by Elsevier in Building and Environment
- Vol. 297
Open AccessCausal cross-modal effects between odor and temperature on occupants’ perception in a single-person office environment
Gebäudesimulation in der Architekturausbildung – Erfahrungen aus der universitären Lehre
Abstrakt: In diesem Beitrag wird eine Taxonomie für den Vergleich von Werkzeugen zur Gebäudesimulation in der Architekturausbildung vorgestellt. Sieben in der Lehre eingesetzte Tools – SimRoom, Therakles, DesignBuilder, WUFi Plus, Ladybug, Honeybee und Climate Studio – werden drei Kategorien zugeordnet: eigenständige Werkzeuge, integrierte GUI‐Werkzeuge und CAD/Engine‐integrierte Werkzeuge. Die Taxonomie zeigt ein Spektrum von transparenten, konzeptorientierten Umgebungen bis zu vollständig eingebetteten, rückkopplungsgesteuerten Systemen im Entwurfsprozess. Entscheidend ist die angemessene Abstimmung der Werkzeugkomplexität auf die Fähigkeiten der Studierenden – eigenständige Tools fördern Grundlagenverständnis, GUI‐Werkzeuge unterstützen analytische Vertiefung, CAD‐integrierte Systeme ermöglichen eine interaktive, performanceorientierte Entwurfsarbeit. Für die Integration in die Lehre sind Zugänglichkeit, intuitive Bedienbarkeit, Mehrdomänenfähigkeit und ein progressiver didaktischer Aufbau zentral. Wird Simulation konsequent in Studios eingebettet, wandelt sie sich von einer nachgelagerten Bewertung zu einem aktiven Gestaltungsfaktor. Der vorgeschlagene Rahmen verbindet technische Eigenschaften mit didaktischen Anforderungen und unterstützt die Auswahl geeigneter Werkzeuge. Künftige Arbeiten sollten auch BIM‐integrierte, webbasierte und cloudbasierte Umgebungen einbeziehen.
Gebäudesimulation in der Architekturausbildung – Erfahrungen aus der universitären Lehre
Abstrakt: In diesem Beitrag wird eine Taxonomie für den Vergleich von Werkzeugen zur Gebäudesimulation in der Architekturausbildung vorgestellt. Sieben in der Lehre eingesetzte Tools – SimRoom, Therakles, DesignBuilder, WUFi Plus, Ladybug, Honeybee und Climate Studio – werden drei Kategorien zugeordnet: eigenständige Werkzeuge, integrierte GUI‐Werkzeuge und CAD/Engine‐integrierte Werkzeuge. Die Taxonomie zeigt ein Spektrum von transparenten, konzeptorientierten Umgebungen bis zu vollständig eingebetteten, rückkopplungsgesteuerten Systemen im Entwurfsprozess. Entscheidend ist die angemessene Abstimmung der Werkzeugkomplexität auf die Fähigkeiten der Studierenden – eigenständige Tools fördern Grundlagenverständnis, GUI‐Werkzeuge unterstützen analytische Vertiefung, CAD‐integrierte Systeme ermöglichen eine interaktive, performanceorientierte Entwurfsarbeit. Für die Integration in die Lehre sind Zugänglichkeit, intuitive Bedienbarkeit, Mehrdomänenfähigkeit und ein progressiver didaktischer Aufbau zentral. Wird Simulation konsequent in Studios eingebettet, wandelt sie sich von einer nachgelagerten Bewertung zu einem aktiven Gestaltungsfaktor. Der vorgeschlagene Rahmen verbindet technische Eigenschaften mit didaktischen Anforderungen und unterstützt die Auswahl geeigneter Werkzeuge. Künftige Arbeiten sollten auch BIM‐integrierte, webbasierte und cloudbasierte Umgebungen einbeziehen.
- Open Access
- 28 October 2025
- Published by Elsevier in Building and Environment
- Vol. 287
Occupants’ willingness to share information for improved comfort and energy efficiency in offices
- 28 October 2025
- Published by Elsevier in Building and Environment
- Vol. 287
Open AccessOccupants’ willingness to share information for improved comfort and energy efficiency in offices
- 23 December 2024
- Published by Springer Nature
- p. 169-175
Tailored Comfort: Revealing Targeted Body Parts for Energy-Efficient Localized Heating and Cooling Systems
- 23 December 2024
- Published by Springer Nature
- p. 169-175
Tailored Comfort: Revealing Targeted Body Parts for Energy-Efficient Localized Heating and Cooling Systems
- Open Access
- 5 June 2024
- Published by Taylor & Francis in Building Research & Information
- Vol. 53 (1-2) , 3-18
An exploration of experts’ views on the relative importance of indoor-environmental quality parameters
- 5 June 2024
- Published by Taylor & Francis in Building Research & Information
- Vol. 53 (1-2) , 3-18
Open AccessAn exploration of experts’ views on the relative importance of indoor-environmental quality parameters
- Open Access
- 2 April 2024
- Published by Elsevier in Energy and Buildings
- Vol. 310
The impact of real-time carbon dioxide awareness on occupant behavior and ventilation rates in student dwellings
- 2 April 2024
- Published by Elsevier in Energy and Buildings
- Vol. 310
Open AccessThe impact of real-time carbon dioxide awareness on occupant behavior and ventilation rates in student dwellings
- Open Access
- 29 November 2023
- Published by Elsevier in Building and Environment
- Vol. 248
The untapped potential of causal inference in cross-modal research
- 29 November 2023
- Published by Elsevier in Building and Environment
- Vol. 248
Open AccessThe untapped potential of causal inference in cross-modal research
- Open Access
- 6 January 2020
- Published by Springer Nature in Scientific Data
- Vol. 7 (1) , 1
Publisher Correction: The Scales Project, a cross-national dataset on the interpretation of thermal perception scales
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 6 January 2020
- Published by Springer Nature in Scientific Data
- Vol. 7 (1) , 1
Open AccessPublisher Correction: The Scales Project, a cross-national dataset on the interpretation of thermal perception scales
An amendment to this paper has been published and can be accessed via a link at the top of the paper.