Hui Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui Zhang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jiewen Deng
Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
4 shared publications - Qingpeng Wei
Department of Building Science, Tsinghua University, Beijing 100084, China
4 shared publications - Chenwei Peng
Department of Building Science, Tsinghua University, Beijing 100084, China
2 shared publications - Mei Liang
Department of Building Science, Tsinghua University, Beijing 100084, China
2 shared publications - Shi He
Department of Building Science, Tsinghua University, Beijing 100084, China
2 shared publications - Yangyang Su
Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publications
Latest Publications
- Open Access
Research on Configuration Optimization and Control Methods for Mid-Deep Geothermal Heat Pumps Coupled with Air-Source Heat Pump Systems for Space Heating in Residential Buildings
Mid-deep geothermal heat pump systems (MD-GHPs) feature high energy efficiency and low energy consumption, yet their promotion is restricted by high initial investment. While the initial investment of air-source heat pumps (ASHPs) is obviously lower, it also has a larger energy consumption. To address the complementary strengths and weaknesses of single-source heat pump systems, this paper puts forward an integrated system combining MD-GHPs and ASHPs, and the series mode was determined as the optimal integration approach for the hybrid system through comparative analysis. Simulation analysis was conducted to explore the adaptability of series mode, and numbers of mid-deep ground heat exchangers in nine cities across various climate regions were studied. The MD-GHP system is suitable for space heating in Xining and Xi’an, while ASHPs are suitable for space heating in Nanjing and Hangzhou. For intermediate resource areas like Urumqi and Tsingdao, the series mode achieves the best economic benefits during the 24th year of operation.
Open AccessResearch on Configuration Optimization and Control Methods for Mid-Deep Geothermal Heat Pumps Coupled with Air-Source Heat Pump Systems for Space Heating in Residential Buildings
Mid-deep geothermal heat pump systems (MD-GHPs) feature high energy efficiency and low energy consumption, yet their promotion is restricted by high initial investment. While the initial investment of air-source heat pumps (ASHPs) is obviously lower, it also has a larger energy consumption. To address the complementary strengths and weaknesses of single-source heat pump systems, this paper puts forward an integrated system combining MD-GHPs and ASHPs, and the series mode was determined as the optimal integration approach for the hybrid system through comparative analysis. Simulation analysis was conducted to explore the adaptability of series mode, and numbers of mid-deep ground heat exchangers in nine cities across various climate regions were studied. The MD-GHP system is suitable for space heating in Xining and Xi’an, while ASHPs are suitable for space heating in Nanjing and Hangzhou. For intermediate resource areas like Urumqi and Tsingdao, the series mode achieves the best economic benefits during the 24th year of operation.
- Open Access
- 19 November 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (22) , 10097
How to Evaluate the Operating Performance of Mid-Deep Geothermal Heat Pump Systems (MD-GHPs): A Study on a Multistage Evaluation Index System
Mid-deep geothermal heat pump systems (MD-GHPs) use mid-deep borehole heat exchangers (MDBHEs) to extract heat from the geothermal energy at a depth of 2–3 km, and have been used for space heating in China over the last decade. This paper proposes a comprehensive and multilevel evaluation-index system to analyze and evaluate the energy performance of MD-GHPs. The multilevel evaluation index system consists of a target layer, a criterion layer, and an index layer, where the criterion layer is subdivided into six aspects and the index layer includes 26 specific indices, reflecting the geothermal resources, heat transfer performance of the MDBHEs, energy efficiency of the heat pump systems, building space heating demand, grid dynamic response capability, and energy-saving and economic benefits. Then, based on both expert survey results and case study data, the entropy weight method and the analytic hierarchy process are integrated to determine indicator weight coefficients among the multilevel evaluation indices, comprehensively considering both subjective and objective analyses. Furthermore, a fuzzy comprehensive evaluation model is conducted to integrate these weighted indices into a multi-criteria evaluation of MD-GHP performance. Finally, the proposed method was applied to evaluate the practical performance of four projects, returning scores of 61.56, 58.33, 72.73, and 78.41. These evaluations enable an overall assessment of the energy performance of MD-GHPs, reflecting the technical weaknesses and offering optimization guidance for system design and operation.
- 19 November 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (22) , 10097
Open AccessHow to Evaluate the Operating Performance of Mid-Deep Geothermal Heat Pump Systems (MD-GHPs): A Study on a Multistage Evaluation Index System
Mid-deep geothermal heat pump systems (MD-GHPs) use mid-deep borehole heat exchangers (MDBHEs) to extract heat from the geothermal energy at a depth of 2–3 km, and have been used for space heating in China over the last decade. This paper proposes a comprehensive and multilevel evaluation-index system to analyze and evaluate the energy performance of MD-GHPs. The multilevel evaluation index system consists of a target layer, a criterion layer, and an index layer, where the criterion layer is subdivided into six aspects and the index layer includes 26 specific indices, reflecting the geothermal resources, heat transfer performance of the MDBHEs, energy efficiency of the heat pump systems, building space heating demand, grid dynamic response capability, and energy-saving and economic benefits. Then, based on both expert survey results and case study data, the entropy weight method and the analytic hierarchy process are integrated to determine indicator weight coefficients among the multilevel evaluation indices, comprehensively considering both subjective and objective analyses. Furthermore, a fuzzy comprehensive evaluation model is conducted to integrate these weighted indices into a multi-criteria evaluation of MD-GHP performance. Finally, the proposed method was applied to evaluate the practical performance of four projects, returning scores of 61.56, 58.33, 72.73, and 78.41. These evaluations enable an overall assessment of the energy performance of MD-GHPs, reflecting the technical weaknesses and offering optimization guidance for system design and operation.
- Open Access
Simulation Analysis on the Heat Performance of Deep Borehole Heat Exchangers in Medium-Depth Geothermal Heat Pump Systems
Deep borehole heat exchangers (DBHEs) extract heat from the medium-depth geothermal energy with the depth of 2–3 km and provide high-temperature heat source for the medium-depth geothermal heat pump systems (MD-GHPs). This paper focuses on the heat transfer performance of DBHEs, where field tests and simulation are conducted to analyze the heat transfer process and the influence factors. Results identify that the heat transfer performance is greatly influenced by geothermal properties of the ground, thermal properties and depth of DBHEs and operation parameters, which could be classified into external factors, internal factors and synergic adjustment. In addition, the long-term operation effects are analyzed with the simulation, results show that with inlet water temperature setting at 20 °C and flow rate setting at 6.0 kg/s, the average outlet water temperature only drops 0.99 °C and the average heat extraction drops 9.5% after 20-years operation. Therefore, it demonstrates that the medium-depth geothermal energy can serve as the high-temperature heat source for heat pump systems stably and reliably. The results from this study can be potentially used to guide the system design and optimization of DBHEs.
Open AccessSimulation Analysis on the Heat Performance of Deep Borehole Heat Exchangers in Medium-Depth Geothermal Heat Pump Systems
Deep borehole heat exchangers (DBHEs) extract heat from the medium-depth geothermal energy with the depth of 2–3 km and provide high-temperature heat source for the medium-depth geothermal heat pump systems (MD-GHPs). This paper focuses on the heat transfer performance of DBHEs, where field tests and simulation are conducted to analyze the heat transfer process and the influence factors. Results identify that the heat transfer performance is greatly influenced by geothermal properties of the ground, thermal properties and depth of DBHEs and operation parameters, which could be classified into external factors, internal factors and synergic adjustment. In addition, the long-term operation effects are analyzed with the simulation, results show that with inlet water temperature setting at 20 °C and flow rate setting at 6.0 kg/s, the average outlet water temperature only drops 0.99 °C and the average heat extraction drops 9.5% after 20-years operation. Therefore, it demonstrates that the medium-depth geothermal energy can serve as the high-temperature heat source for heat pump systems stably and reliably. The results from this study can be potentially used to guide the system design and optimization of DBHEs.
- Open Access
- 26 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (23) , 5120
What Is the Main Difference between Medium-Depth Geothermal Heat Pump Systems and Conventional Shallow-Depth Geothermal Heat Pump Systems? Field Tests and Comparative Study
Recently, the medium-depth geothermal heat pump systems (MD-GHPs) have been applied for space heating in China. Theoretically, the MD-GHPs use deep borehole heat exchangers (DBHEs) to extract heat from the medium-depth geothermal energy with the depth of 2~3 km, thus, improving the energy performance of whole systems obviously. This paper conducts field tests of nine conventional shallow-depth geothermal heat pump systems (SD-GHPs) and eight MD-GHPs to analyze the energy performance of heat pump systems, as well as heat transfer performance of ground heat exchangers. Then the comparative studies are carried out to analyze the difference between these two ground coupled heat pump systems. Field test results show that the outlet water temperature of DBHEs in MD-GHP can reach more than 30 °C with heat extraction of 195.2 kW~302.8 kW per DBHE with a depth of 2500 m, which are much higher than that of SD-GHPs. However, the heat pumps and water pumps in the ground side should be specially designed to fit the high-temperature heat source instead of following operation mode of SD-GHPs. Then with variable speed compressor which has high energy efficiency under a wide range of load rate and compressor ratio, and with the ground-side water pumps which efficiently operate under high water resistance and low flow rate, the COP of heat pumps and COPs of whole systems could reach 7.80 and 6.46 separately. Thus, the advantage of high-temperature heat source could be fully utilized to achieve great energy-saving effects.
- 26 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (23) , 5120
Open AccessWhat Is the Main Difference between Medium-Depth Geothermal Heat Pump Systems and Conventional Shallow-Depth Geothermal Heat Pump Systems? Field Tests and Comparative Study
Recently, the medium-depth geothermal heat pump systems (MD-GHPs) have been applied for space heating in China. Theoretically, the MD-GHPs use deep borehole heat exchangers (DBHEs) to extract heat from the medium-depth geothermal energy with the depth of 2~3 km, thus, improving the energy performance of whole systems obviously. This paper conducts field tests of nine conventional shallow-depth geothermal heat pump systems (SD-GHPs) and eight MD-GHPs to analyze the energy performance of heat pump systems, as well as heat transfer performance of ground heat exchangers. Then the comparative studies are carried out to analyze the difference between these two ground coupled heat pump systems. Field test results show that the outlet water temperature of DBHEs in MD-GHP can reach more than 30 °C with heat extraction of 195.2 kW~302.8 kW per DBHE with a depth of 2500 m, which are much higher than that of SD-GHPs. However, the heat pumps and water pumps in the ground side should be specially designed to fit the high-temperature heat source instead of following operation mode of SD-GHPs. Then with variable speed compressor which has high energy efficiency under a wide range of load rate and compressor ratio, and with the ground-side water pumps which efficiently operate under high water resistance and low flow rate, the COP of heat pumps and COPs of whole systems could reach 7.80 and 6.46 separately. Thus, the advantage of high-temperature heat source could be fully utilized to achieve great energy-saving effects.