Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aayush Shrivastava has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Swarm Intelligence in Deepfake Detection: A Comprehensive Survey

    by Sakshi Pundir, Abhishek Sharma, Sumit Pundir, Aayush Shrivastava

  • Lightweight Deepfake Detection Using Transfer Learning and Swarm-Based Optimization

    by Sakshi Pundir, Abhishek Sharma, Sumit Pundir, Aayush Shrivastava

  • Open Access

    A Systematic Review of Multimodal Frameworks for Assessing Health Vulnerability in Academicians Across Ergonomic, Lifestyle, and Dietary Domains

    by Pooja Oza, Shraddha Phansalkar, Aayush Shrivastava, Abhishek Sharma, Jun-Jiat Tiang, Wei Hong Lim

    Background: Lifestyle challenges such as prolonged sitting, irregular dietary habits, high stress levels, and lack of physical activity have become increasingly common among working professionals. All these factors contribute to the risk of chronic diseases such as diabetes, heart disease, obesity, and high blood pressure, which in turn result in reduced work performance and quality of life and may further affect health services access through increase healthcare needs. The teaching environment, like many other work environments, is mentally, emotionally, and practically demanding, and it puts extra pressure on those who work in it. Academicians, who devote themselves to guiding young minds, often make unhealthy daily choices and face significant work-related stress, which can lead to serious long-term health problems. This review highlights that health and well-being are shaped not by a single factor such as diet, work patterns, or habits, but by their combined effect. Methods: A study of around 113 studies has highlighted that academicians usually feel drained and physically exhausted. Result: The factors like prolonged fasts, insufficient water intake, long-standing hours, long and continuous talking, and extended periods in the sitting position have added to their stress levels at the workplace. The most critical finding is that these factors do not affect in isolation but impact as a combined interaction. These issues influence each other, thus increasing the vulnerability to lifestyle disorders. Conclusions: This critical problem can be addressed with a Multimodal Assessment Framework that integrates teachers’ data on dietary habits, workplace ergonomics, sleep quality, and levels of physical activity. The presented work also proposes a statistical technique with an Artificial Intelligence (AI) model, and generates Vulnerability Quotient (VQ) that show lifestyle disease-related exposure of the teachers, which may be further used to provide remedial interventions. These insights can further guide institutions and policymakers to design healthier, supportive, and sustainable teaching environments.


  • Gas Leakage Detection Using Hyper Tuned Machine Learning Algorithms

    by Sameeksha Verma, Shyam Akashe, Abhishek Sharma, Aayush Shrivastava


  • Open Access

    Digital Crackers as a Sustainable Alternative: Designing a High-Decibel, Emission-Free Firework Simulation Using Node Mcu

    by Lalit Kumar, Aayush Shrivastava, Abhishek Sharma, Ritu Gupta

    Using digital crackers be a part of modern, digital India, a step closer towards sustainable and safe health-focused Diwali. This study investigates the use of digital crackers instead of fireworks, which cause a lot of air and noise pollution. Digital crackers utilise advanced technologies such as AR, VR, IoT-based devices, and LED-based simulators that not only ensure a safe, reusable, and eco-friendly experience but also provide a rich usage experience. Here, we propose a Node MCU-based prototype to mimic firework effects with visual as well as auditory effects without producing any emission of pollutants and low noise. Data was collected on the prototype energy efficiencies, noise impact, cost-effectiveness, and user perspective under a controlled environment. Findings showed digital crackers offer potential to be an eco-friendly alternative to the bursting of traditional firecrackers while garnering widespread user acceptance, suggesting these can be mainstreamed to shape future festive practices.

  • Open Access

    Hybrid Protection Scheme Based Optimal Overcurrent Relay Coordination Strategy for RE Integrated Power Distribution Grid

    by Aayush Shrivastava, Abhishek Sharma, Manjaree Pandit, Vibhu Jately, Brian Azzopardi

    A directional overcurrent relay is commonly used to protect the power distribution networks of a distributed system. The selection of the appropriate settings for the relays is an important component of the protection strategies used to isolate the faulty parts of the system. The rapid growth of distributed generation (DG) systems present new challenges to these protection schemes. The effect of solar photovoltaic power plants on relay coordination is studied initially in this research work. A protection strategy was formulated to guarantee that the increased penetration of solar photovoltaic (PV) plants does not affect the relay coordination time. This paper addresses these issues associated with a high penetration of DG through the use of a hybrid protection scheme. The protection strategy is divided into two parts. The first part is based on an optimal fault current limiter value estimated with respect to constraints and the optimal time multiplier setting, and then the coordination time interval is estimated with respect to constraint in Part II. The results of these analyses show that a hybrid protection scheme can effectively handle the complexity of distributed generation (DG) and dynamic relay coordination problems. In this research, three optimization algorithms have been used for calculating the estimated value of impedance fault current limiter (Zfcl) and time multiplier setting (TMS). The response time of hybrid protection schemes is very important. If the computational time of their proposed algorithms is less than their actual computational time, then their response time to address the issue is also less. The performance in all algorithms was identified to arrive at a conclusion that the grey wolf optimized algorithm (GWO) algorithm can substantially reduce the computational time needed to implement hybrid protection algorithms. The GWO algorithm takes a computational time of 0.946 s, achieving its feasible solution in less than 1 s.


  • Relay Coordination Optimization for Solar PV Integrated Grid Using the Water Cycle Optimization Algorithm

    by Manjaree Pandit, Aayush Shrivastava, Devender Saini

    The distribution generation system is considered to be one of the leading components of the electrical grid structure and is gaining more importance, particularly in the smart grid model. Due to the increasing penetration of distributed generation (DG) sources, the modern distributed system structure has been significantly enhanced. Traditional distribution network protection schemes are vulnerable to serious threats owing to the presence of multiple DG units. Due to the high level of DG penetration integration, there is a problem of overcurrent. Due to a high fault current, the relay coordination time interval constraint may be violated. This chapter presents the solution for relay coordination by considering the penetration issue. The water cycle algorithm was used to optimize the coordination of relays with regard to practical constraints.

  • Peer Review of Renewable Energy-based Adaptive Protection(s) & Relay Coordination Optimization Techniques

    by Aayush Shrivastava, Devender Kumar Saini, Manjaree Pandit

    Background: Distributed Sustainable Energy Generation (DSEG) has become the leading trend in modern R&D to achieve practical, financial and environmental benefits. From the viewpoint of power system, the benefits are reduction in power failures, enhancement of energy quality & reliability, congestion relief and smart/micro grid demand response. The widespread use of modern technologies, on the one hand provides the use of DSEG for safe power production and power loss reduction. On the other hand, it also offer new challenges such as optimal placement of relays, protection device settings, and voltage control problems in power systems. Among the various solutions reported in literature, widely accepted solution seems to be the deployment of Fault Current Limiter (FCL) to minimize DSEG impacts. However, FCLs are expensive option to restore relay coordination. Adaptive protection scheme provides benefit to the smart grid's advanced features and serves as an efficient solution to address new DSEG and FCL challenges. Objective: This paper offers an extensive review of, the effect of DSEG on distribution systems from safety point of view, optimization techniques used for adaptive protections, optimal relay coordination and merits & demerits of FCL. Methods: Paper discuss many recent optimization and hybrid optimization techniques used for solving optimal relay coordination model (ORC). Adaptive and FCL based non adaptive techniques are also discussed to solve this model. An attempt has also been made to present comparative study of various optimization techniques in tabular form, considering different bus models and their outcomes. Conclusion: Various optimization techniques have used by researchers to solve the vital issue of DSEG impacts on distribution grid. Comparative study of these techniques shows that, Water cycle optimization, hybrid whale-GWO and GSASQP algorithms results are found to give better results in solving the ORC problem. FCL based non-adaptive technique found better as compare with adaptive techniques because a greater number of DGs can be integrated on grid with less complexity.


  • Cuckoo Search Algorithm: A Review of Recent Variants and Engineering Applications

    by Abhishek Sharma, Vinay Chowdary, Aayush Srivastava, Puneet Joshi


  • Open Access

    Relay co-ordination optimization for integrated solar photo-voltaic power distribution grid

    by Aayush Shrivastava, Devender Kumar Saini, Manjaree Pandit

    Distributed generation (DG) specifically from solar energy is gaining much attention. Integration of solar photo-voltaic plant (SPP) on distribution grid increases flexibility of the system but lacking behind in terms of convention protection scheme. The impact of orientation of point of common coupling (PCC) of SPP on distribution grid changes the entire power flow computation and hence, coordination of protection devices. This paper presents the power flow computation on modified IEEE 4-bus system for different integrated positions of SPP. Further analysis is carried for the fault current level with different locations and number of SPP DG. It has been found that DG integration increases the magnitudes of fault current; hence, it will have impact on relay co-ordination. A MATLAB/Simulink model is proposed for relay mis-coordination and optimal co-ordination by implementing evolutionary optimization technique. The Proposed study on IEEE 4-bus system along with three units 100 kW capacity of SPP is used to derived optimal co-ordination solution which validates the obtained results on electrical transient’s analysis programming platform (ETAP).