PLPeter Lübcke

Peter Lübcke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Lübcke has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Retrieval of absolute SO2 column amounts from scattered-light spectra: implications for the evaluation of data from automated DOAS networks

    by Peter Lübcke, Johannes Lampel, Santiago Arellano, Nicole Bobrowski, Florian Dinger, Bo Galle, Gustavo Garzón, Silvana Hidalgo, Zoraida Chacón Ortiz, Leif Vogel, et al.

    Scanning spectrometer networks using scattered solar radiation in the ultraviolet spectral region have become an increasingly important tool for monitoring volcanic sulfur dioxide (SO2) emissions. Often measured spectra are evaluated using the differential optical absorption spectroscopy (DOAS) technique. In order to obtain absolute column densities (CDs), the DOAS evaluation requires a Fraunhofer reference spectrum (FRS) that is free of absorption structures of the trace gas of interest. For measurements at volcanoes such a FRS can be readily obtained if the scan (i.e. series of measurements at different elevation angles) includes viewing directions where the plume is not seen. In this case, it is possible to use these viewing directions (e.g. zenith) as FRS. Possible contaminations of the FRS by the plume can then be corrected by calculating and subtracting an SO2 offset (e.g. the lowest SO2 CD) from all viewing directions of the respective scan. This procedure is followed in the standard evaluations of data from the Network for Observation of Volcanic and Atmospheric Change (NOVAC). While this procedure is very efficient in removing Fraunhofer structures and instrumental effects it has the disadvantage that one can never be sure that there is no SO2 from the plume in the FRS. Therefore, using a modelled FRS (based on a high-resolution solar atlas) has a great advantage. We followed this approach and investigated an SO2 retrieval algorithm using a modelled FRS. In this paper, we present results from two volcanoes that are monitored by NOVAC stations and which frequently emit large volcanic plumes: Nevado del Ruiz (Colombia) recorded between January 2010 and June 2012 and from Tungurahua (Ecuador) recorded between January 2009 and December 2011. Instrumental effects were identified with help of a principal component analysis (PCA) of the residual structures of the DOAS evaluation. The SO2 retrieval performed extraordinarily well with an SO2 DOAS retrieval error of 1 − 2 × 1016 [molecules cm−2]. Compared to a standard evaluation, we found systematic differences of the differential slant column density (dSCD) of only up to ≈ 15 % when looking at the variation of the SO2 within one scan. The major advantage of our new retrieval is that it yields absolute SO2 CDs and that it does not require complicated instrumental calibration in the field (e.g. by employing calibration cells or broadband light sources), since the method exploits the information available in the measurements. We compared our method to an evaluation that is similar to the NOVAC approach, where a spectrum that is recorded directly before the scan is used as an FRS and an SO2 CD offset is subtracted from all retrieved dSCD in the scan to correct for possible SO2 contamination of the FRS. The investigation showed that 21.4 % of the scans (containing significant amounts of SO2) at Nevado del Ruiz and 7 % of the scans at Tungurahua showed much larger SO2 CDs when evaluated using modelled FRS (more than a factor of 2). For standard evaluations the overall distribution of the SO2 CDs in a scan can in some cases indicate whether the plume affects all viewing directions and thus these scans need to be discarded for NOVAC emission rate evaluation. However, there are other cases where this is not possible and thus the reported SO2 emission rates would be underestimated. The new method can be used to identify these cases and thus it can considerably improve SO2 emission budgets.


  • Open Access

    Retrieval of absolute SO2 column amounts from scattered-light spectra – Implications for the evaluation of data from automated DOAS Networks

    by Peter Lübcke, Johannes Lampel, Santiago Arellano, Nicole Bobrowski, Florian Dinger, Bo Galle, Gustavo Garzón, Silvana Hidalgo, Zoraida Chacón Ortiz, Leif Vogel, et al.

    Scanning Differential Optical Absorption Spectroscopy (DOAS) networks using scattered solar radiation have become an increasingly important tool for monitoring volcanic sulphur dioxide (SO2) emissions. In order to get absolute column densities (CDs), the DOAS evaluation requires a Fraunhofer Reference Spectrum (FRS) that is free of absorption structures of the trace gas of interest. At volcanoes, this requirement can be formulated in a weaker form, if there is a plume free viewing direction within the spectra of a scan through the complete sky. In this case, it is possible to use a specific viewing direction (e.g. zenith) as FRS and correcting for possible plume contamination in the FRS by calculating and subtracting an SO2 offset (e.g. the lowest SO2 CD) from all viewing directions of the respective scan. This procedure is followed in the standard evaluations of data from the Network for Observation of Volcanic and Atmospheric Change (NOVAC). While this procedure is very efficient in removing Fraunhofer structures and instrumental effects it has the disadvantage that one can never be sure that there is no SO2 from the plume in the FRS. Therefore, using a modelled FRS (based on a high-resolution Solar atlas) is of great advantage. We followed this approach and investigated an SO2 retrieval algorithm using a modelled FRS. In this manuscript, we present results from two volcanoes that are monitored by NOVAC stations and which also often show a large volcanic plume. Results from a DOAS SO2 evaluation using a modelled FRS are presented for data from Nevado del Ruiz (Colombia) recorded between January 2010 and June 2012 and from Tungurahua (Ecuador) recorded between January 2009 and December 2011. Instrumental effects were identified with help of a Principal Component Analysis (PCA) of the residual structures of the DOAS evaluation. The SO2 retrieval performed extraordinarily well with an SO2 DOAS retrieval error of 1−2 × 1016 [molecules/cm2]. Compared to a regular evaluation (using a FRS recorded directly before the scan), we found systematic differences of the differential Slant Column Density (dSCD) of only up to 15 % when looking at the variation of the SO2 within one scan. The major advantage of our new retrieval is that it yields absolute SO2 CDs and that it does not require complicated instrumental calibration in the field, since the method exploits the information available in the measurements.


  • Open Access

    On the absolute calibration of SO2 cameras

    by P. Lübcke, N. Bobrowski, S. Illing, C. Kern, J. M. Alvarez Nieves, L. Vogel, J. Zielcke, H. Delgado Granados, U. Platt

    Sulphur dioxide emission rate measurements are an important tool for volcanic monitoring and eruption risk assessment. The SO2 camera technique remotely measures volcanic emissions by analysing the ultraviolet absorption of SO2 in a narrow spectral window between 300 and 320 nm using solar radiation scattered in the atmosphere. The SO2 absorption is selectively detected by mounting band-pass interference filters in front of a two-dimensional, UV-sensitive CCD detector. One important step for correct SO2 emission rate measurements that can be compared with other measurement techniques is a correct calibration. This requires conversion from the measured optical density to the desired SO2 column density (CD). The conversion factor is most commonly determined by inserting quartz cells (cuvettes) with known amounts of SO2 into the light path. Another calibration method uses an additional narrow field-of-view Differential Optical Absorption Spectroscopy system (NFOV-DOAS), which measures the column density simultaneously in a small area of the camera's field-of-view. This procedure combines the very good spatial and temporal resolution of the SO2 camera technique with the more accurate column densities obtainable from DOAS measurements. This work investigates the uncertainty of results gained through the two commonly used, but quite different, calibration methods (DOAS and calibration cells). Measurements with three different instruments, an SO2 camera, a NFOV-DOAS system and an Imaging DOAS (I-DOAS), are presented. We compare the calibration-cell approach with the calibration from the NFOV-DOAS system. The respective results are compared with measurements from an I-DOAS to verify the calibration curve over the spatial extent of the image. The results show that calibration cells, while working fine in some cases, can lead to an overestimation of the SO2 CD by up to 60% compared with CDs from the DOAS measurements. Besides these errors of calibration, radiative transfer effects (e.g. light dilution, multiple scattering) can significantly influence the results of both instrument types. The measurements presented in this work were taken at Popocatépetl, Mexico, between 1 March 2011 and 4 March 2011. Average SO2 emission rates between 4.00 and 14.34 kg s−1 were observed.