Yan Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yan Luo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Tao Lu
Beijing Univ Chem Technol, Sch Mech & Elect Engn, Beijing 100029, Peoples R China
3 shared publications Gen Li
Beijing University of Chemical Technology
2 shared publications- Ruixing Wang
Key Laboratory for Mechanics in Fluid Solid Coupling Systems, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications Dexia Yuan
Beijing University of Chemical Technology
1 shared publication- Gen Li
School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
1 shared publication Jian Deng
Nucl Power Inst China, Sci & Technol Reactor Syst Design Technol Lab, Chengdu 610041, Peoples R China
1 shared publication
Latest Publications
- 9 November 2025
- Published by Springer Nature
- p. 231-242
Study on Flow Heat Transfer and Acoustic Characteristics During Quenching Process
- 9 November 2025
- Published by Springer Nature
- p. 231-242
Study on Flow Heat Transfer and Acoustic Characteristics During Quenching Process
- 10 May 2023
- Published by Springer Nature
- p. 1071-1081
Economic Analysis of Nuclear Cogeneration System Based on High-Temperature Gas-Cooled Reactor
- 10 May 2023
- Published by Springer Nature
- p. 1071-1081
Economic Analysis of Nuclear Cogeneration System Based on High-Temperature Gas-Cooled Reactor
- Open Access
- 16 November 2022
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 17, 1385-1398
Analysis of thermal stress, fatigue life and allowable flux density for the molten salt receiver in solar power tower plants
The solar power tower (SPT) receiver design should be able to stand with fatigue damage caused by the passage of clouds, start-up and shut-down. In this paper, to investigate the impacts of incident heat flux distribution and SPT site weather data on the thermal stress, fatigue life and allowable flux density (AFD) of the molten salt receiver, the relationship between the fatigue life and AFD of the tube wall is developed based on the coupled thermal-structural analysis and Miner linear damage theory. The results show that whether the cosine effect of the circumferential heat flux distribution considered has a significant influence on the location and magnitude of the maximum thermal stress of the tube wall, which lead to the difference in the tube wall fatigue damage. The AFD are respectively 829 kW/m2 and 1037 kW/m2 under uniform and cosine circumferential heat flux distributions for the site of Barstow, USA when the design lifetime of the tube is 30 years. Compared with the SPT site of Barstow, USA, the fatigue damage of the tube wall in Sevilla, Spain and Delingha, China are lower under the same conditions due to lower insolation hours of DNI in the range of 750-1100 W/m2. The AFD are respectively 829 kW/m2, 973 kW/m2 and 997 kW/m2 for the site of Barstow, USA, Sevilla, Spain and Delingha, China with 30 years design life. These findings give guidelines for the operation reliability of the SPT molten salt receiver tube.
- 16 November 2022
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 17, 1385-1398
Open AccessAnalysis of thermal stress, fatigue life and allowable flux density for the molten salt receiver in solar power tower plants
The solar power tower (SPT) receiver design should be able to stand with fatigue damage caused by the passage of clouds, start-up and shut-down. In this paper, to investigate the impacts of incident heat flux distribution and SPT site weather data on the thermal stress, fatigue life and allowable flux density (AFD) of the molten salt receiver, the relationship between the fatigue life and AFD of the tube wall is developed based on the coupled thermal-structural analysis and Miner linear damage theory. The results show that whether the cosine effect of the circumferential heat flux distribution considered has a significant influence on the location and magnitude of the maximum thermal stress of the tube wall, which lead to the difference in the tube wall fatigue damage. The AFD are respectively 829 kW/m2 and 1037 kW/m2 under uniform and cosine circumferential heat flux distributions for the site of Barstow, USA when the design lifetime of the tube is 30 years. Compared with the SPT site of Barstow, USA, the fatigue damage of the tube wall in Sevilla, Spain and Delingha, China are lower under the same conditions due to lower insolation hours of DNI in the range of 750-1100 W/m2. The AFD are respectively 829 kW/m2, 973 kW/m2 and 997 kW/m2 for the site of Barstow, USA, Sevilla, Spain and Delingha, China with 30 years design life. These findings give guidelines for the operation reliability of the SPT molten salt receiver tube.
- Open Access
- 23 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (21) , 10740
Analysis of Temperature and Thermal Stress for a Solar Power Tower Molten Salt Receiver under Multi-Source Uncertainties
Although uncertainties such as solar radiation and material properties are generally involved in the solar receiver design process, current studies in the solar receiver field are based on deterministic models and do not incorporate these uncertainties into the design process. In this paper, based on a coupled deterministic thermal–structural model and an uncertainty analysis model, an analysis of temperature and thermal stress was conducted for a solar power tower (SPT) molten salt receiver under multi-source uncertainties to investigate the dispersions of responses. The results demonstrated that the maximum temperature inside the tube wall under multi-source uncertainties ranged from 847 K to 895 K, with an expectation of 871 K and a standard deviation of 8 K, and the maximum thermal stress ranged from 173 MPa to 245 MPa, with an expectation of 204 MPa and a standard deviation of 12 MPa, both of which had severer probabilities than the deterministic results (871 K and 204 MPa) and may cause failure in the receiver. Furthermore, the results of the global sensitivity analysis indicated that the peak incident solar flux was the most sensitive, and the specific heat of the tube material was the least sensitive to the maximum temperature and thermal stress of the tube wall. These results are beneficial to provide additional reliability and confidence in the temperature and thermal stress evaluation process of solar receiver tubes.
- 23 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (21) , 10740
Open AccessAnalysis of Temperature and Thermal Stress for a Solar Power Tower Molten Salt Receiver under Multi-Source Uncertainties
Although uncertainties such as solar radiation and material properties are generally involved in the solar receiver design process, current studies in the solar receiver field are based on deterministic models and do not incorporate these uncertainties into the design process. In this paper, based on a coupled deterministic thermal–structural model and an uncertainty analysis model, an analysis of temperature and thermal stress was conducted for a solar power tower (SPT) molten salt receiver under multi-source uncertainties to investigate the dispersions of responses. The results demonstrated that the maximum temperature inside the tube wall under multi-source uncertainties ranged from 847 K to 895 K, with an expectation of 871 K and a standard deviation of 8 K, and the maximum thermal stress ranged from 173 MPa to 245 MPa, with an expectation of 204 MPa and a standard deviation of 12 MPa, both of which had severer probabilities than the deterministic results (871 K and 204 MPa) and may cause failure in the receiver. Furthermore, the results of the global sensitivity analysis indicated that the peak incident solar flux was the most sensitive, and the specific heat of the tube material was the least sensitive to the maximum temperature and thermal stress of the tube wall. These results are beneficial to provide additional reliability and confidence in the temperature and thermal stress evaluation process of solar receiver tubes.
- Open Access
- 23 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (21) , 10734
Uncertainty-Based Comprehensive Optimization Design for the Thermal Protection System of Hypersonic Wing Structure
Due to the inherent uncertainties in material properties, loads, geometric dimensions, et al., the uncertainty-based optimization design method has become increasingly important for the design of the thermal protection system (TPS) by carefully considering the influences of uncertainties. In this study, an uncertainty-based comprehensive optimization design method, which sequentially performs the robust design of aerodynamic shape and structure size for the TPS of a hypersonic wing is proposed, on the presence of uncertain-but-bounded parameters. The robust design of the TPS’s aerodynamic shape is firstly carried out. The results show that the proposed method decreases the fluctuation of the lift-to-drag ratio by 5.7%, with a small increase of heat flux on the stagnation point by only 0.13% when compared with the conventional deterministic optimization method. After that, based on the optimized aerodynamic shape and heating loads, the robust design of the multilayer TPS tile is conducted. The results show that the mass of the TPS tile efficiently deceased from 2.713 kg to 2.445 kg by 9.89%, and the robustness of the optimized design is better than the initial design. Finally, the effectiveness of the proposed optimization method is validated by the heat insulting experiment of the typical multilayer TPS tiles.
- 23 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (21) , 10734
Open AccessUncertainty-Based Comprehensive Optimization Design for the Thermal Protection System of Hypersonic Wing Structure
Due to the inherent uncertainties in material properties, loads, geometric dimensions, et al., the uncertainty-based optimization design method has become increasingly important for the design of the thermal protection system (TPS) by carefully considering the influences of uncertainties. In this study, an uncertainty-based comprehensive optimization design method, which sequentially performs the robust design of aerodynamic shape and structure size for the TPS of a hypersonic wing is proposed, on the presence of uncertain-but-bounded parameters. The robust design of the TPS’s aerodynamic shape is firstly carried out. The results show that the proposed method decreases the fluctuation of the lift-to-drag ratio by 5.7%, with a small increase of heat flux on the stagnation point by only 0.13% when compared with the conventional deterministic optimization method. After that, based on the optimized aerodynamic shape and heating loads, the robust design of the multilayer TPS tile is conducted. The results show that the mass of the TPS tile efficiently deceased from 2.713 kg to 2.445 kg by 9.89%, and the robustness of the optimized design is better than the initial design. Finally, the effectiveness of the proposed optimization method is validated by the heat insulting experiment of the typical multilayer TPS tiles.