Jiachi Hong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jiachi Hong has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Pengcheng Li
Huazhong University of Science and Technology
8 shared publications Jinling Lu
Hainan University
6 shared publicationsXuan Zhu
Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology
4 shared publicationsWenting Zhu
3 shared publicationsChen Wang
HUST-Suzhou Institute for Brainsmatics
2 shared publications- David Huang
Casey Eye Institute, Department of Ophthalmology, Oregon Health & Science University, Portland, OR, USA
2 shared publications
Latest Publications
- Open Access
- 20 May 2026
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 289, 68-75
Opacity Detection on Optical Coherence Tomography Based on an Incidence-Angle and Depth-Dependent Model of Corneal Reflectance
- 20 May 2026
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 289, 68-75
Open AccessOpacity Detection on Optical Coherence Tomography Based on an Incidence-Angle and Depth-Dependent Model of Corneal Reflectance
- 3 November 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (12) , 4917-4928
Convolutional neural network-based differentiation of intraocular inflammatory cells with ultrahigh-resolution OCT
The differential diagnosis of uveitis is broad and often challenging. A key indicator of intraocular inflammation is the presence of cells in the aqueous or vitreous humor. We developed a lightweight convolutional neural network (CNN) model capable of classifying intraocular inflammatory cell types using ultrahigh-resolution optical coherence tomography (OCT). The model was trained and optimized using OCT images of known cell types—mononuclear cells and granulocytes—and achieved an accuracy of 88.4 ± 0.6%, with an area under the receiver operating characteristic (ROC) curve of 94.3 ± 0.4%. The inflammatory cell compositions predicted by the model were consistent with clinical diagnoses in uveitis patients. This approach offers a promising tool for the diagnosis and monitoring of intraocular inflammation in uveitis.
- 3 November 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (12) , 4917-4928
Convolutional neural network-based differentiation of intraocular inflammatory cells with ultrahigh-resolution OCT
The differential diagnosis of uveitis is broad and often challenging. A key indicator of intraocular inflammation is the presence of cells in the aqueous or vitreous humor. We developed a lightweight convolutional neural network (CNN) model capable of classifying intraocular inflammatory cell types using ultrahigh-resolution optical coherence tomography (OCT). The model was trained and optimized using OCT images of known cell types—mononuclear cells and granulocytes—and achieved an accuracy of 88.4 ± 0.6%, with an area under the receiver operating characteristic (ROC) curve of 94.3 ± 0.4%. The inflammatory cell compositions predicted by the model were consistent with clinical diagnoses in uveitis patients. This approach offers a promising tool for the diagnosis and monitoring of intraocular inflammation in uveitis.
- 17 October 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (21) , 45346-45356
Hybrid decorrelation optical coherence tomography for quantification of wide-dynamic-range blood perfusion
Accurate quantification of blood perfusion is critical for understanding vascular pathophysiology. Although optical coherence tomography (OCT) can offer an insight into the blood perfusion by measuring three-dimensional blood flow velocity, existing OCT velocimetry techniques based on dynamic light scattering face inaccurate measurements of blood perfusion due to limited measurable dynamic range with a finite sampling frequency dependent on a specific swept-source laser or spectrometer. High-speed saturation or low-speed overestimation makes it challenging to cover the entire parabolic velocity distribution like Poiseuille flow in a blood vessel, in which the non-Newtonian shear-thinning behavior of blood fundamentally governs velocity gradients. Here, we proposed hybrid decorrelation (HD) OCT to enable blood perfusion quantification. HD-OCT interpreted the blood flow velocity at slow regimes based on the temporal intensity correlation function, while with its temporal integration in fast-flow regions. It achieved a measurement of blood flow velocity from 0.5 to 400 mm/s. HD-OCT improved the accuracy of blood perfusion measurement based on a precise cross-sectional velocity distribution.
- 17 October 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (21) , 45346-45356
Hybrid decorrelation optical coherence tomography for quantification of wide-dynamic-range blood perfusion
Accurate quantification of blood perfusion is critical for understanding vascular pathophysiology. Although optical coherence tomography (OCT) can offer an insight into the blood perfusion by measuring three-dimensional blood flow velocity, existing OCT velocimetry techniques based on dynamic light scattering face inaccurate measurements of blood perfusion due to limited measurable dynamic range with a finite sampling frequency dependent on a specific swept-source laser or spectrometer. High-speed saturation or low-speed overestimation makes it challenging to cover the entire parabolic velocity distribution like Poiseuille flow in a blood vessel, in which the non-Newtonian shear-thinning behavior of blood fundamentally governs velocity gradients. Here, we proposed hybrid decorrelation (HD) OCT to enable blood perfusion quantification. HD-OCT interpreted the blood flow velocity at slow regimes based on the temporal intensity correlation function, while with its temporal integration in fast-flow regions. It achieved a measurement of blood flow velocity from 0.5 to 400 mm/s. HD-OCT improved the accuracy of blood perfusion measurement based on a precise cross-sectional velocity distribution.
- 10 April 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (5) , 1856-1870
Non-ergodicity and noise-corrected diffuse speckle contrast analysis in deep tissue blood flow measurement
Diffuse speckle contrast analysis (DSCA) is a valuable technique for monitoring blood flow speed, but its accuracy and sensitivity are often compromised by system noise and non-ergodicity, particularly in deep tissue measurements. Noise and static scattering tissues lead to overestimated speckle contrast and consequent underestimation of blood flow speed, especially in regions of rapid flow. To address these challenges, we developed a noise correction method integrated with a non-ergodicity calibrated model to enhance the sensitivity and accuracy of DSCA. A guide for selecting an appropriate core diameter and numerical aperture was provided for multi-mode fiber DSCA. Validation through phantom and in vivo experiments demonstrated that the non-ergodicity and noise-corrected DSCA improved the sensitivity of blood flow speed measurements in deep tissues.
- 10 April 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (5) , 1856-1870
Non-ergodicity and noise-corrected diffuse speckle contrast analysis in deep tissue blood flow measurement
Diffuse speckle contrast analysis (DSCA) is a valuable technique for monitoring blood flow speed, but its accuracy and sensitivity are often compromised by system noise and non-ergodicity, particularly in deep tissue measurements. Noise and static scattering tissues lead to overestimated speckle contrast and consequent underestimation of blood flow speed, especially in regions of rapid flow. To address these challenges, we developed a noise correction method integrated with a non-ergodicity calibrated model to enhance the sensitivity and accuracy of DSCA. A guide for selecting an appropriate core diameter and numerical aperture was provided for multi-mode fiber DSCA. Validation through phantom and in vivo experiments demonstrated that the non-ergodicity and noise-corrected DSCA improved the sensitivity of blood flow speed measurements in deep tissues.
- 18 June 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (13) , 3600-3603
Ergodic speckle contrast optical coherence tomography velocimetry of rapid blood flow
Visualizing a 3D blood flow velocity field through noninvasive imaging is crucial for analyzing hemodynamic mechanisms in areas prone to disorders. However, traditional correlation-based optical coherence tomography (OCT) velocimetry techniques have a maximum measurable flow velocity depending on the A-line rate. We presented the ergodic speckle contrast OCT (ESCOCT) to break the bottleneck in measuring the rapid blood flow velocity. It achieved a measurement of blood flow velocity ranging from 9.5 to 280 mm/s using a 100 kHz swept-source (SS) OCT based on 100 A-repeats scanning mode. Addressing the non-ergodic problem of temporal OCT signals by integrating more consecutive A-scans, ESCOCT can enable the estimation for lower velocity flows by increasing A-repeats. ESCOCT provided a wide dynamic range with no upper limit on measuring blood flow velocity with an adequate signal-to-noise ratio and improved the sensitivity and accuracy of the hemodynamic assessment.
- 18 June 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (13) , 3600-3603
Ergodic speckle contrast optical coherence tomography velocimetry of rapid blood flow
Visualizing a 3D blood flow velocity field through noninvasive imaging is crucial for analyzing hemodynamic mechanisms in areas prone to disorders. However, traditional correlation-based optical coherence tomography (OCT) velocimetry techniques have a maximum measurable flow velocity depending on the A-line rate. We presented the ergodic speckle contrast OCT (ESCOCT) to break the bottleneck in measuring the rapid blood flow velocity. It achieved a measurement of blood flow velocity ranging from 9.5 to 280 mm/s using a 100 kHz swept-source (SS) OCT based on 100 A-repeats scanning mode. Addressing the non-ergodic problem of temporal OCT signals by integrating more consecutive A-scans, ESCOCT can enable the estimation for lower velocity flows by increasing A-repeats. ESCOCT provided a wide dynamic range with no upper limit on measuring blood flow velocity with an adequate signal-to-noise ratio and improved the sensitivity and accuracy of the hemodynamic assessment.
- 12 February 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (5) , 6887-6902
Dual-exposure temporal laser speckle imaging for simultaneously accessing microvascular blood perfusion and angiography
Laser speckle contrast imaging (LSCI) has gained significant attention in the biomedical field for its ability to map the spatio-temporal dynamics of blood perfusion in vivo. However, LSCI faces difficulties in accurately resolving blood perfusion in microvessels. Although the transmissive detecting geometry can improve the spatial resolution of tissue imaging, ballistic photons directly transmitting forward through tissue without scattering will cause misestimating in the flow speed by LSCI because of the lack of a quantitative theoretical model of transmissvie LSCI. Here, we develop a model of temporal LSCI which accounts for the effect of nonscattered light on estimating decorrelation time. Based on this model, we further propose a dual-exposure temporal laser speckle imaging method (dEtLSCI) to correct the overestimation of background speed when performing traditional transmissive LSCI, and reconstruct microvascular angiography using the scattered component extracted from total transmitted light. Experimental results demonstrated that our new method opens an opportunity for LSCI to simultaneously resolve the blood vessels morphology and blood flow speed at microvascular level in various contexts, ranging from the drug-induced vascular response to angiogenesis and the blood perfusion monitoring during tumor growth.
- 12 February 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (5) , 6887-6902
Dual-exposure temporal laser speckle imaging for simultaneously accessing microvascular blood perfusion and angiography
Laser speckle contrast imaging (LSCI) has gained significant attention in the biomedical field for its ability to map the spatio-temporal dynamics of blood perfusion in vivo. However, LSCI faces difficulties in accurately resolving blood perfusion in microvessels. Although the transmissive detecting geometry can improve the spatial resolution of tissue imaging, ballistic photons directly transmitting forward through tissue without scattering will cause misestimating in the flow speed by LSCI because of the lack of a quantitative theoretical model of transmissvie LSCI. Here, we develop a model of temporal LSCI which accounts for the effect of nonscattered light on estimating decorrelation time. Based on this model, we further propose a dual-exposure temporal laser speckle imaging method (dEtLSCI) to correct the overestimation of background speed when performing traditional transmissive LSCI, and reconstruct microvascular angiography using the scattered component extracted from total transmitted light. Experimental results demonstrated that our new method opens an opportunity for LSCI to simultaneously resolve the blood vessels morphology and blood flow speed at microvascular level in various contexts, ranging from the drug-induced vascular response to angiogenesis and the blood perfusion monitoring during tumor growth.
- 27 July 2023
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 170
Correcting non-rigid intra-frame motion of laser speckle contrast imaging by heterogeneous regression analysis
- 27 July 2023
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 170
Correcting non-rigid intra-frame motion of laser speckle contrast imaging by heterogeneous regression analysis
- 14 May 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (10) , 2505-2508
Quantitative laser speckle auto-inverse covariance imaging for robust estimation of blood flow
We present a quantitative model to provide robust estimation of the decorrelation time using laser speckle auto-inverse covariance. It has the advantages of independence from the statistical sample size, speckle size, static scattering, and detector noise. We have shown cerebral blood flow imaging through an intact mouse skull using this model. Phantom experiments and two animal models, middle cerebral artery occlusion, and cortical spreading depression were used to evaluate its performance.
- 14 May 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (10) , 2505-2508
Quantitative laser speckle auto-inverse covariance imaging for robust estimation of blood flow
We present a quantitative model to provide robust estimation of the decorrelation time using laser speckle auto-inverse covariance. It has the advantages of independence from the statistical sample size, speckle size, static scattering, and detector noise. We have shown cerebral blood flow imaging through an intact mouse skull using this model. Phantom experiments and two animal models, middle cerebral artery occlusion, and cortical spreading depression were used to evaluate its performance.
- 3 April 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (5) , 2339-2351
Extendable, large-field multi-modal optical imaging system for measuring tissue hemodynamics
Simultaneous imaging of multiple hemodynamic parameters helps to evaluate the physiological and pathological status of biological tissue. To achieve multimodal hemodynamics imaging with a large field of view, an infinite conjugate relay lens system compatible with the standard C-Mount camera lens is designed to adapt one camera lens with multiple CCD/CMOS cameras for simultaneously multi-wavelength imaging. Using this relay lens system, dual wavelength reflectance imaging and laser speckle contrast imaging were combined to simultaneously detect the changes in blood flow, oxygenation, and hemoglobin concentrations. To improve the accuracy of hemoglobin concentration measurement with an LED illumination source, an integral algorithm is proposed that accounts for the dependence of differential pathlength factors (DPF) on hemoglobin concentrations and the integral effect of both the emission spectrum of the light source and the spectrum response of the detector. The imaging system is validated by both phantom and in vivo experiments, including the arterial occlusion, and the detection of blood volume pulse (BVP) and blood flow pulse (BFP) signal in human subjects. The system helps in the exploration of macroscopic tissue hemodynamics.
- 3 April 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (5) , 2339-2351
Extendable, large-field multi-modal optical imaging system for measuring tissue hemodynamics
Simultaneous imaging of multiple hemodynamic parameters helps to evaluate the physiological and pathological status of biological tissue. To achieve multimodal hemodynamics imaging with a large field of view, an infinite conjugate relay lens system compatible with the standard C-Mount camera lens is designed to adapt one camera lens with multiple CCD/CMOS cameras for simultaneously multi-wavelength imaging. Using this relay lens system, dual wavelength reflectance imaging and laser speckle contrast imaging were combined to simultaneously detect the changes in blood flow, oxygenation, and hemoglobin concentrations. To improve the accuracy of hemoglobin concentration measurement with an LED illumination source, an integral algorithm is proposed that accounts for the dependence of differential pathlength factors (DPF) on hemoglobin concentrations and the integral effect of both the emission spectrum of the light source and the spectrum response of the detector. The imaging system is validated by both phantom and in vivo experiments, including the arterial occlusion, and the detection of blood volume pulse (BVP) and blood flow pulse (BFP) signal in human subjects. The system helps in the exploration of macroscopic tissue hemodynamics.
- 27 November 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (23) , 5812-5815
Laser speckle auto-inverse covariance imaging for mean-invariant estimation of blood flow
Laser speckle contrast imaging maps the changes in blood flow by estimating the decorrelation time of a scattered light field. However, speckle contrast is a biased statistics estimator that results in a theoretic bias between its expected value and the true value. Moreover, the average of speckle contrast depends on the statistical sampling size, which further hinders the estimation of decorrelation time from speckle contrast. Here, we present a new, to the best of our knowledge, unbiased statistics analysis based on auto-inverse covariance to improve the estimation of decorrelation time using laser speckle. Theoretical and experimental results demonstrate that the speckle auto-inverse covariance analysis is mean-invariant, so that the average of the estimation is not dependent on the sampling size. Furthermore, it can produce less statistical fluctuation, especially for slow flow, and consume less computation time than that of speckle contrast analysis.
- 27 November 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (23) , 5812-5815
Laser speckle auto-inverse covariance imaging for mean-invariant estimation of blood flow
Laser speckle contrast imaging maps the changes in blood flow by estimating the decorrelation time of a scattered light field. However, speckle contrast is a biased statistics estimator that results in a theoretic bias between its expected value and the true value. Moreover, the average of speckle contrast depends on the statistical sampling size, which further hinders the estimation of decorrelation time from speckle contrast. Here, we present a new, to the best of our knowledge, unbiased statistics analysis based on auto-inverse covariance to improve the estimation of decorrelation time using laser speckle. Theoretical and experimental results demonstrate that the speckle auto-inverse covariance analysis is mean-invariant, so that the average of the estimation is not dependent on the sampling size. Furthermore, it can produce less statistical fluctuation, especially for slow flow, and consume less computation time than that of speckle contrast analysis.