MMMohammad Reza Mohebbian

Mohammad Reza Mohebbian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammad Reza Mohebbian has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Predicting COVID-19 Hospital Stays with Kolmogorov–Gabor Polynomials: Charting the Future of Care

    by Hamidreza Marateb, Mina Norouzirad, Kouhyar Tavakolian, Faezeh Aminorroaya, Mohammadreza Mohebbian, Miguel Ángel Mañanas, Sergio Romero Lafuente, Ramin Sami, Marjan Mansourian

    Optimal allocation of ward beds is crucial given the respiratory nature of COVID-19, which necessitates urgent hospitalization for certain patients. Several governments have leveraged technology to mitigate the pandemic’s adverse impacts. Based on clinical and demographic variables assessed upon admission, this study predicts the length of stay (LOS) for COVID-19 patients in hospitals. The Kolmogorov–Gabor polynomial (a.k.a., Volterra functional series) was trained using regularized least squares and validated on a dataset of 1600 COVID-19 patients admitted to Khorshid Hospital in the central province of Iran, and the five-fold internal cross-validated results were presented. The Volterra method provides flexibility, interactions among variables, and robustness. The most important features of the LOS prediction system were inflammatory markers, bicarbonate (HCO3), and fever—the adj. R2 and Concordance Correlation Coefficients were 0.81 [95% CI: 0.79–0.84] and 0.94 [0.93–0.95], respectively. The estimation bias was not statistically significant (p-value = 0.777; paired-sample t-test). The system was further analyzed to predict “normal” LOS ≤ 7 days versus “prolonged” LOS > 7 days groups. It showed excellent balanced diagnostic accuracy and agreement rate. However, temporal and spatial validation must be considered to generalize the model. This contribution is hoped to pave the way for hospitals and healthcare providers to manage their resources better.


  • ECG compression using optimized B-spline

    by Mohammad Reza Mohebbian, Khan A. Wahid


  • Fetal ECG Extraction From Maternal ECG Using Attention-Based CycleGAN

    by Mohammad Reza Mohebbian, Seyed Shahim Vedaei, Khan A. Wahid, Anh Dinh, Hamid Reza Marateb, Kouhyar Tavakolian

    A non-invasive fetal electrocardiogram (FECG) is used to monitor the electrical pulse of the fetal heart. Decomposing the FECG signal from the maternal ECG (MECG) is a blind source separation problem, which is hard due to the low amplitude of the FECG, the overlap of R waves, and the potential exposure to noise from different sources. Traditional decomposition techniques, such as adaptive filters, require tuning, alignment, or pre-configuration, such as modeling the noise or desired signal to map the MECG to the FECG. The high correlation between maternal and fetal ECG fragments decreases the performance of convolution layers. Therefore, the masking region of interest based on the attention mechanism was performed to improve the signal generators' precision. The sine activation function was also used to retain more details when converting two signal domains. Three available datasets from the Physionet, including the A&D FECG, NI-FECG, and NI-FECG challenge, and one synthetic dataset using FECGSYN toolbox, were used to evaluate the performance. The proposed method could map an abdominal MECG to a scalp FECG with an average of 98% R-Square [CI 95%: 97%, 99%] as the goodness of fit on the A&D FECG dataset. Moreover, it achieved 99.7% F1-score [CI 95%: 97.8-99.9], 99.6% F1-score [CI 95%: 98.2%, 99.9%] and 99.3% F1-score [CI 95%: 95.3%, 99.9%] for fetal QRS detection on the A&D FECG, NI-FECG and NI-FECG challenge datasets, respectively. Also, the distortion was in the “very good” and “good” ranges. These results are comparable to the state-of-the-art results; thus, the proposed algorithm has the potential to be used for high-performance signal-to-signal conversion.


  • Open Access

    Which K-Space Sampling Schemes is good for Motion Artifact Detection in Magnetic Resonance Imaging?

    by Mohammad Reza Mohebbian, Ekta Walia, Khan A. Wahid

    Motion artifacts are a common occurrence in the Magnetic Resonance Imaging (MRI) exam. Motion during acquisition has a profound impact on workflow efficiency, often requiring a repeat of sequences. Furthermore, motion artifacts may escape notice by technologists, only to be revealed at the time of reading by the radiologists, affecting their diagnostic quality. Designing a computer-aided tool for automatic motion detection and elimination can improve the diagnosis, however, it needs a deep understanding of motion characteristics. Motion artifacts in MRI have a complex nature and it is directly related to the k-space sampling scheme. In this study we investigate the effect of three conventional k-space samplers, including Cartesian, Uniform Spiral and Radial on motion induced image distortion. In this regard, various synthetic motions with different trajectories of displacement and rotation are applied to T1 and T2-weighted MRI images, and a convolutional neural network is trained to show the difficulty of motion classification. The results show that the spiral k-space sampling method get less effect of motion artifact in image space as compared to radial k-space sampled images, and radial k-space sampled images are more robust than Cartesian ones. Cartesian samplers, on the other hand, are the best in terms of deep learning motion detection because they can better reflect motion.


  • Open Access

    Developing Non-Laboratory Cardiovascular Risk Assessment Charts and Validating Laboratory and Non-Laboratory-Based Models

    by Razieh Hassannejad, Marjan Mansourian, Hamidreza Marateb, Mohammad Reza Mohebian, Thomas Andrew Gaziano, Rodney T Jackson, Emanuele Di Angelantonio, Nizal Sarrafzadegan

    Developing simplified risk assessment model based on non-laboratory risk factors that could determine cardiovascular risk as accurately as laboratory-based one can be valuable, particularly in developing countries where there are limited resources. To develop a simplified non-laboratory cardiovascular disease risk assessment chart based on previously reported laboratory-based chart and evaluate internal and external validation, and recalibration of both risk models to assess the performance of risk scoring tools in other population. A 10-year non-laboratory-based risk prediction chart was developed for fatal and non-fatal CVD using Cox Proportional Hazard regression. Data from the Isfahan Cohort Study (ICS), a population-based study among 6504 adults aged ≥ 35 years, followed-up for at least ten years was used for the non-laboratory-based model derivation. Participants were followed up until the occurrence of CVD events. Tehran Lipid and Glucose Study (TLGS) data was used to evaluate the external validity of both non-laboratory and laboratory risk assessment models in other populations rather than one used in the model derivation. The discrimination and calibration analysis of the non-laboratory model showed the following values of Harrell’s C: 0.73 (95% CI 0.71–0.74), and Nam-D’Agostino χ2:11.01 (p = 0.27), respectively. The non-laboratory model was in agreement and classified high risk and low risk patients as accurately as the laboratory one. Both non-laboratory and laboratory risk prediction models showed good discrimination in the external validation, with Harrell’s C of 0.77 (95% CI 0.75–0.78) and 0.78 (95% CI 0.76–0.79), respectively. Our simplified risk assessment model based on non-laboratory risk factors could determine cardiovascular risk as accurately as laboratory-based one. This approach can provide simple risk assessment tool where laboratory testing is unavailable, inconvenient, and costly.


  • Classifying MRI motion severity using a stacked ensemble approach

    by MohammadReza Mohebbian, Ekta Walia, Mohammad Habibullah, Shawn Stapleton, Khan A. Wahid


  • Open Access

    Accurate Diagnosis of Suicide Ideation/Behavior Using Robust Ensemble Machine Learning: A University Student Population in the Middle East and North Africa (MENA) Region

    by Azam Naghavi, Tobias Teismann, Zahra Asgari, Mohammad Reza Mohebbian, Marjan Mansourian, Miguel Ángel Mañanas

    Suicide is one of the most critical public health concerns in the world and the second cause of death among young people in many countries. However, to date, no study can diagnose suicide ideation/behavior among university students in the Middle East and North Africa (MENA) region using a machine learning approach. Therefore, stability feature selection and stacked ensembled decision trees were employed in this classification problem. A total of 573 university students responded to a battery of questionnaires. Three-fold cross-validation with a variety of performance indices was sued. The proposed diagnostic system had excellent balanced diagnosis accuracy (AUC = 0.90 [CI 95%: 0.86–0.93]) with a high correlation between predicted and observed class labels, fair discriminant power, and excellent class labeling agreement rate. Results showed that 23 items out of all items could accurately diagnose suicide ideation/behavior. These items were psychological problems and how to experience trauma, from the demographic variables, nine items from Post-Traumatic Stress Disorder Checklist (PCL-5), two items from Post Traumatic Growth (PTG), two items from the Patient Health Questionnaire (PHQ), six items from the Positive Mental Health (PMH) questionnaire, and one item related to social support. Such features could be used as a screening tool to identify young adults who are at risk of suicide ideation/behavior.


  • Automated Detection of Bleeding in Capsule Endoscopy Using On-Chip Multispectral Imaging Sensors

    by Mohammad Reza Mohebbian, Hanif Ali Sohag, Seyed Shahim Vedaei, Khan A. Wahid

    Gastrointestinal (GI) bleeding is a common problem and may lead to fatal consequences. The detection of bleeding is currently determined through conventional examination of wireless capsule endoscopy (WCE) images. Image-based bleeding detection is performed using only color pixels; therefore, image and color distortion affect the accuracy of RGB-based methods adversely. On the other hand, imaging modalities like multispectral features contain several unique characteristics of the target material, and therefore are less error-prone. In this regard, an on-chip bleeding detection sensor based on blood's optical properties is developed in this article. For creating this sensor, an array of 12 optical sensors, six in visible and six in near-infrared range, is tested with blood samples (BS) in various concentrations and non-blood samples (NBS), such as food pigments and natural foods (digestible and nondigestible). Various feature selection and machine learning approaches have been used to select the optimal bandwidth for the best detection accuracy. A capsule prototype is designed that uses 450 nm, 610 nm, and 810 nm of wavelengths. The prototype is tested in two in vitro experiments using two porcine intestines to validate the proof of concept. The results indicate that the designed system can distinguish occult and acute bleeding from a distance of 1 cm with angles of 45 and 90 degrees. An F1-score of 99% is achieved using the bagged decision tree algorithm. The proposed solution for detecting GI bleeding will eliminate the need to use a camera module and large data transmission, and thereby consumes 1.48 times less power than conventional WCE systems.


  • Open Access

    COVID-SAFE: An IoT-Based System for Automated Health Monitoring and Surveillance in Post-Pandemic Life

    by Seyed Shahim Vedaei, Amir Fotovvat, Mohammad Reza Mohebbian, Gazi M. E. Rahman, Khan A. Wahid, Paul Babyn, Hamid Reza Marateb, Marjan Mansourian, Ramin Sami

    In the early months of the COVID-19 pandemic with no designated cure or vaccine, the only way to break the infection chain is self-isolation and maintaining the physical distancing. In this paper, we present a potential application of the Internet of Things (IoT) in healthcare and physical distance monitoring for pandemic situations. The proposed framework consists of three parts: a lightweight and low-cost IoT node, a smartphone application (app), and fog-based Machine Learning (ML) tools for data analysis and diagnosis. The IoT node tracks health parameters, including body temperature, cough rate, respiratory rate, and blood oxygen saturation, then updates the smartphone app to display the user health conditions. The app notifies the user to maintain a physical distance of 2 m (or 6 ft), which is a key factor in controlling virus spread. In addition, a Fuzzy Mamdani system (running at the fog server) considers the environmental risk and user health conditions to predict the risk of spreading infection in real time. The environmental risk conveys from the virtual zone concept and provides updated information for different places. Two scenarios are considered for the communication between the IoT node and fog server, 4G/5G/WiFi, or LoRa, which can be selected based on environmental constraints. The required energy usage and bandwidth (BW) are compared for various event scenarios. The COVID-SAFE framework can assist in minimizing the corona-virus exposure risk.