FMFranz Muigg

Franz Muigg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Franz Muigg has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Abklärung und Versorgung von konnatalen Hörstörungen

    by Viktor Weichbold, Elisabeth Zangerl, Ruth Schröcksnadel, Maria Wechselberger, Franz Muigg

  • Effects of Interaural Timing Delays on Speech Perception in Noise in Bilateral Cochlear Implant Users

    by Philipp Zelger, Tobias Raffelsberger, Annett Franke-Trieger, Thomas Keintzel, Joachim Schmutzhard, Franz Muigg, Markus Rungger, Josef Seebacher

    Introduction: Precise interaural timing and level cues are critical for spatial hearing and speech understanding in noise. Bilateral cochlear implant (CI) users provide a controlled model to investigate how artificially introduced interaural timing disparities affect binaural hearing. This study investigates whether introducing a unilateral time delay in CI stimulation affects speech perception in noise and spatial release from masking (SRM). Methods: Eleven bilateral CI users were tested using the German Oldenburger Sentence Test (OLSA) under three spatial noise conditions (S0N0, S0N+90°, S0N–90°), with and without a 10-ms delay introduced to the right CI processor. Speech reception thresholds (SRTs) and SRM were analyzed using repeated-measures ANOVA. Results: No significant differences in SRT or SRM were found between the delay and non-delay conditions across all spatial configurations. A consistent right-ear advantage was observed, but the induced interaural delay did not significantly impair speech-in-noise performance. Conclusion: A unilateral 10-ms delay in CI stimulation does not significantly affect speech perception or SRM in bilateral CI users. These findings indicate that a unilateral 10-ms interaural delay does not measurably affect speech perception or SRM in bilateral CI users. This observation is consistent with previous reports suggesting limited functional use of fine-grained interaural timing cues during speech-in-noise processing, although the present study cannot draw conclusions about smaller interaural delays.

  • Open Access

    Pre-Stimulus Head Position and Its Effect on Sound Localization Metrics in Children

    by Elisabeth Zangerl, Franz Muigg, Josef Seebacher, Simone Graf, Philipp Zelger

    Background: This study investigates the impact of initial head position prior to stimulus presentation on sound localization accuracy in children. The quadratic angular root mean square error (RMSE) and the linear mean-absolute-error (MAE) have been considered for this study. Material and Methods: A total of 28 normal-hearing children (ages 6–10) participated in sound localization. The participants localized sounds presented from five speakers at the frontal semicircle. Head positions at stimulus onset were tracked using glasses with a built-in webcam. The localization results were analyzed with and without correcting for the offset from the frontal direction of the initial head position prior to stimulus presentation. Results: The initial head position prior to stimulus presentation significantly affected the RMSE but had no influence on the MAE. This effect was stronger in younger children. The MAE showed fewer changes in head position due to its linear nature, which reduces the effect of large errors. An analysis of the children’s initial head positions revealed a tendency to deviate from the frontal direction. Therefore, the initial head position prior to stimulus presentation should be considered when calculating localization measures. Conclusions: The initial head position prior to a stimulus can distort the RMSE in directional hearing tests for children, while the MAE remains robust against such deviations.

  • Open Access

    Beyond averaging: A transformer approach to decoding event related brain potentials

    by Philipp Zelger, Manuel Arnold, Sonja Rossi, Josef Seebacher, Franz Muigg, Simone Graf, Antonio Rodríguez-Sánchez


  • Does cochlear implantation affect personality of hearing-impaired patients? A five-year follow-up study

    by Franz Muigg, Philipp Zelger, Josef Seebacher, Joachim Schmutzhard, Viktor W. Weichbold

    Background: Previous studies found that in patients with profound hearing loss the NEO- personality factor Openness-to-experience is lowered. Objective: Assuming that lowered Openness-to-experience may be due to limited access to sounds, we hypothesized that levels of Openness-to-experience would increase in these patients after cochlear implantation. Material and methods: Twenty adults (mean age: 61 years; active CI users) with bilateral profound hearing loss were assessed with the NEO-Five-Factor-Inventory before cochlear implantation (pre) and five years later (post). Results: No significant pre-post changes in personality were seen. Both before and five years after cochlear implantation, the sample had normal age- and gender-specific mean values on the factors Extraversion, Neuroticism, Agreeableness, and Conscientiousness (T approximate to 50), but significantly lowered mean values on Openness-to-experience (T approximate to 42, p < 0.001). Conclusions and significance: Cochlear implantation apparently has no (or at best very little) effect on Openness-to-experience in profoundly hearing impaired patients. While this study demonstrates once again, that high-grade hearing loss may be associated with less openness to new experiences, the reason for this association remains unclear.

  • Perceived social support improves health-related quality of life in cochlear implant patients

    by Franz Muigg, Sonja Rossi, Heike Kühn, Viktor Weichbold

    Purpose Perceived social support has been shown to positively correlate with health-related quality of life (HR-QoL) in a variety of conditions. This study investigated whether perceived social support is affecting HR-QoL of patients who receive a cochlear implant (CI) for deafness. Methods Eighty eight adults (56 males, 32 females; mean age: 60 years) with a uni- or bilateral CI for bilateral high-grade hearing loss were administered two questionnaires: a questionnaire for perceived social support (FSU-14) and the Nijmegen Cochlear Implant Questionnaire (NCIQ) for hearing-specific HR-QoL. Administration of the questionnaires occurred at four points in time: before implantation and three, 12 and 24 months after implant activation. Results The CI patients had quite high levels of perceived social support (mean percentile rank: 71), which remained stable at all four measurement points. Multivariate Analysis showed a significant interaction between perceived social support and HR-QoL indicating that higher perceived social support lead to higher improvement of HR-QoL after cochlear implantation. Conclusion The CI patients in this study had higher than average levels of perceived social support, which did not change before and after cochlear implantation. Perceived social support and HR-QoL were related such that patients with high levels of perceived social support experienced greater improvement of their HR-QoL after cochlear implantation than patients with low levels of perceived social support. Based on this finding, perceived social support must be considered as an important factor for HR-QoL after cochlear implantation.


  • 5-Year Observation Period of Quality of Life After Cochlear Implantation

    by Viktor Weichbold, Philipp Zelger, Oliver Galvan, Franz Muigg

    Background: Only few studies assessed health-related quality of life (HRQoL) in cochlear implant (CI) patients for a period of more than 2 years. Some of these studies indicated that HRQoL might decrease after that period. The goal of our study was to see whether HRQoL indeed decreases or remains stable beyond 2 years after implant activation. Methods: Twenty-five adults (11 women, 14 men; mean age at implantation: 60 ± 19 yr) with a unilateral CI for profound hearing loss were administered two questionnaires: the Nimjegen Cochlear Implant Questionnaire and the Health Utility Index 3 (HUI 3). The Nimjegen Cochlear Implant Questionnaire total score and the HUI single-attribute utility score of Hearing are measures of hearing-specific HRQoL, whereas the HUI multiattribute utility score is a measure of generic HRQoL. The questionnaires were administered before cochlear implantation and 1, 2, and 5 years after implant activation. Results: Hearing-specific HRQoL was significantly improved at 1 year after implant activation and did not significantly change thereafter. Generic HRQoL also showed significant improvement at 1 year after implant activation, but deteriorated to a clinically relevant degree thereafter. Conclusions: The significant improvement of hearing-specific HRQoL obtained from cochlear implantation was fully maintained for up to 5 years after implantation. Generic HRQoL of our CI patients, however, fluctuated over time. The decrease of generic HRQoL is supposed to reflect general age-associated health declines.


  • Does Cochlear Implantation Affect Openness-to-Experience in Profound Postlingual Hearing Loss?

    by Franz Muigg, Viktor W Weichbold, Heike Kuehn, Josef Seebacher, Oliver Galvan

    Recent studies suggest that hearing loss in postlingually deafened adults may be associated with lowered levels of the personality factor Openness to experience. This study investigated whether cochlear implantation in postlingually deafened adults raises the level of Openness to experience. Fifty-five postlingually deafened adults (mean age: 63 years) were assessed with the Neuroticism-Extraversion-Openness-Five-Factor-Inventory (NEO-FFI), a questionnaire capturing the five personality factors Extraversion, Openness to experience, Neuroticism, Agreeableness, and Conscientiousness. Personality assessment occurred before cochlear implantation and 24 months after implant activation. On factors Extraversion, Neuroticism, Agreeableness, and Conscientiousness the mean scores of the sample were equal to population norms, both before and after cochlear implantation. On factor Openness to experience, the mean score was significantly lower before cochlear implantation, and remained so thereafter. Openness to experience may be reduced in some groups of deaf or hard of hearing persons. Cochlear implantation had no effect on any personality factor, at least not after two years of implant use.


  • Cochlear implantation in adults with single-sided deafness: generic and disease-specific long-term quality of life

    by Franz Muigg, Harald R. Bliem, Heike Kühn, Josef Seebacher, Bernhard Holzner, Viktor W. Weichbold

    To determine the 2-year outcome of health-related quality of life (HRQoL) in adults who received a cochlear implant (CI) for single-sided deafness (SSD).