Ramy S. A. Afia has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimal Dispatch and Energy Management of Hybrid Microgrids: A Case Study of an Urban Community

    by Mohamed Hussein, Abdallah Mohamed, Ahmed F. Bendary, Helmy El Zoghby, Heba Hassan, Matti Lehtonen, Mohamed M. F. Darwish, Ramy S. A. Afia

    Energy is a vital component of life today, and providing reliable power access remains a significant global challenge, particularly in remote areas. In Egypt, several isolated regions, including parts of South Sinai, suffer from limited electricity access. This study presents an enhanced environmental and techno-economic modeling of an off-grid hybrid renewable energy microgrid (HREM) tailored for such regions. A proposed configuration combining photovoltaic (PV) panels, wind turbines (WTs), a converter (CONV), and battery energy storage is evaluated to meet the residential energy demand of an isolated community in South Sinai. Four feasible system models, PV/CONV/BAT, WT/CONV/BAT, PV/WT/CONV/BAT, and a standalone diesel generator, were simulated using hybrid optimization of multiple energy resources. The cost of energy was analyzed under different scenarios. The results show that the combination of a 1109 kW PV system, 16 × 25 kW WTs, 439 kW converter, and 353 batteries is the best configuration that leads to the lowest values of Net Present Cost (NPC) and Levelized Cost of Energy (COE), and zero unmet load, making it the most economically and environmentally viable configuration.


  • Open Access

    Degradation Assessment of In-Service Transformer Oil Based on Electrical and Chemical Properties

    by Ehtasham Mustafa, Bilal Ahmad, Malik Imran Ali, Ramy S. A. Afia, Rahmat Ullah

    In order to ensure the long-term reliability and safety of power transformers, it is important to continuously monitor the characteristics of insulating oil, which not only helps in understanding its behavior over time but also ensures the safety of the equipment. The current study analyzes in-service insulating oil with the aim of relating deterioration and changes in the oil with service aging. Insulating oil samples were collected from three power transformers, with a voltage level of 220 kV and 132 kV, installed at a 220 kV substation. Electrical and chemical characteristics were obtained, and the impact of service aging and the relationships among load variation, oil, and winding temperatures with the characteristics were evaluated. Variations in the dielectric dissipation factor and breakdown voltage with service aging were recorded for all transformers, while the moisture content increased with each service year. Among the concentrations of gases present in the insulating oil, carbon monoxide, oxygen, and nitrogen concentrations increased after each service year. The impact of load variation on the breakdown voltage of the 132 kV transformer oil was more prominent than for the 220 kV transformers. The analysis of gas ratios and moisture content identified the degradation of cellulose insulation in all transformers, which was due to the presence of electrical faults.


  • Open Access

    Islanded Microgrids Frequency Support Using Green Hydrogen Energy Storage With AI-Based Controllers

    by Helmy M. El Zoghby, Ayman Safwat Samir, Ahmed F. Bendary, Abdelmonem Hazem, Haitham S. Ramadan, Mahmoud M. Elmesalawy, Ramy S. A. Afia

    Islanded microgrids, powered by renewable energy sources, offer a sustainable electricity solution for remote areas. However, maintaining frequency stability in these systems remains a challenge due to the intermittent nature of renewables. This research proposes an approach to enhance microgrid stability by integrating a green hydrogen energy storage system (GHESS) and employing advanced AI-based control strategies. The GHESS plays a pivotal role in storing excess renewable energy as hydrogen and then converting it back to electricity when needed, reducing reliance on traditional backup generators. To optimize microgrid performance, a hybrid single-neuron PID (SNPID) controller, augmented by machine learning techniques, is developed and compared against conventional proportional, integral, and derivative PID and fuzzy self-tuning PID (FSTPID) controllers. The system’s performance was evaluated using four realistic scenarios. In all cases, the SNPID controller significantly outperformed the existing options. It achieved a 58% reduction in frequency fluctuations compared to the fuzzy self-tuning PID (FSTPID) controller and an impressive 87% reduction compared to the traditional PID controller. The Simulation results underscore the SNPID controller’s exceptional performance in frequency stability, emphasizing the transformative potential of AI for microgrid management.


  • Open Access

    Implementation of Non-Destructive Condition Monitoring Techniques on Low-Voltage Nuclear Cables: II. Thermal Aging of EPR/CSPE Cables

    by Ehtasham Mustafa, Ramy S. A. Afia, Aamir Nawaz, Oumaima Nouini, Zoltán Ádám Tamus

    Determining the aging state of low-voltage nuclear power plant cables using a nondestructive and reliable condition monitoring technique is highly desirable as the cables experience multiple aging stresses during the service period. This paper deals with the implementation and investigation of such nondestructive techniques, which can detect the overall aging state of low-voltage instrumentation and control (I&C) cables, which are subjected to accelerated thermal aging. The dielectric spectroscopy, extended voltage response, and polarization–depolarization current as nondestructive electrical aging techniques were used for the investigation purpose, while the elongation at break was also adopted as a mechanical measurement and for comparison. Prominent variations in the electrical parameters for the insulation and jacket were observed, whereas the elongation at break for both materials also decreased under thermal aging. Based on the electrical techniques, aging markers were selected that showed a strong correlation with the aging and elongation at break, proving the ability of the adopted electrical methods as a nondestructive condition monitoring technique.


  • Open Access

    Aging Assessment of XLPE/CSPE LV Nuclear Power Cables Under Simultaneous Radiation–Mechanical Stresses

    by Ramy S.A. Afia, Ehtasham Mustafa, Zoltán Ádám Tamus


  • Open Access

    Comparison of Mechanical and Low-Frequency Dielectric Properties of Thermally and Thermo-Mechanically Aged Low Voltage CSPE/XLPE Nuclear Power Plant Cables

    by Ramy S. A. Afia, Ehtasham Mustafa, Zoltán Ádám Tamus

    During the service period of low-voltage nuclear cables, multiple stresses influence the aging of polymeric materials of cables. Thermal and radiation stresses are considered service aging factors in qualification tests, while the standards usually do not prescribe mechanical stress. CSPE/XLPE insulated nuclear cable samples were exposed to thermal and combined thermo-mechanical aging for more than 1200 h at 120 °C. The real and imaginary parts of permittivity were measured in the 200 μHz to 50 mHz range as dielectric properties. The Shore D hardness of the samples was measured to analyze the mechanical characteristics of the cable. To characterize the dielectric spectrum, derived quantities, namely central real and imaginary permittivities and real and imaginary permittivities’ central frequencies were calculated. The change of dielectric spectra did not show a clear trend with aging, but the imaginary permittivity’s central frequency was higher by 0.5 mHz in the case of thermo-mechanically aged samples. The Shore D hardness was also higher on the thermo-mechanically aged samples. These findings show the combined aging has a higher impact on the insulation properties. Hence, involving the mechanical stress in the aging procedure of cable qualification enables the design of more robust cables in a harsh environment.


  • Open Access

    Aging Mechanisms and Non-Destructive Aging Indicators of XLPE/CSPE Unshielded LV Nuclear Power Cables Subjected to Simultaneous Radiation-Mechanical Aging

    by Ramy S. A. Afia, Ehtasham Mustafa, Zoltán Ádám Tamus

    Low-voltage cable systems in nuclear power plants are key components that have a crucial role in the safe operation of nuclear facilities. Thus, the aging management of cable systems is of utmost importance as they cannot easily or economically be replaced or upgraded. Therefore, there is a continuous need to develop reliable non-destructive condition monitoring techniques, mostly based on the measurement of the dielectric properties of cable insulation. This paper introduces the changing of dielectric and mechanical properties of XLPE insulated and CSPE jacketed unshielded low-voltage nuclear power plant power cable in case of simultaneous mechanical and radiation aging. The cable samples were bent and exposed to 400 kGy gamma irradiation with a 0.5 kGy/hr dose rate. Dielectric response (real and imaginary permittivity) in the 0.1 Hz−1 kHz frequency range, extended voltage response (EVR), and the Shore D hardness test techniques were measured to track aging. The electrical and mechanical parameters have increased monotonically with aging, except the imaginary permittivity, which increased only at frequencies higher than 10 Hz. Furthermore, different quantities were deducted based on the frequency and permittivity data. The electrical parameters and deducted quantities correlation with aging and mechanical parameters were investigated. Since the deducted quantities and the electrical parameters are strongly correlated with absorbed dose and mechanical properties, the electrical measurements can be applied as a non-destructive aging indicator for XLPE/CSPE unshielded low-voltage nuclear power cables.


  • Open Access

    Implementation of Non-Destructive Electrical Condition Monitoring Techniques on Low-Voltage Nuclear Cables: I. Irradiation Aging of EPR/CSPE Cables

    by Ehtasham Mustafa, Ramy S. A. Afia, Oumaima Nouini, Zoltán Ádám Tamus

    In a nuclear power plant environment, low-voltage cables experience different stresses during their service life which challenge their integrity. A non-destructive and reliable condition monitoring technique is desired to determine the state of these low-voltage cables during service and for the life extension of nuclear power plants. Hence, in this research work, an EPR/CSPE-based low-voltage cable was exposed to γ-rays for five different absorbed doses. The overall behavior of the cable under stress was characterized by frequency and time domain electrical measurements (capacitance, tan δ, and Extended Voltage Response) and a mechanical measurement (elongation at break). Significant variations in the electrical parameters were observed, as was a decline in the elongation at break values. A strong correlation between the measurement methods was observed, showing the ability of the electrical methods to be adopted as a non-destructive condition monitoring technique.


  • Open Access

    Electrical and Mechanical Condition Assessment of Low Voltage Unshielded Nuclear Power Cables Under Simultaneous Thermal and Mechanical Stresses: Application of Non-Destructive Test Techniques

    by Ramy S. A. Afia, Mustafa Ehtasham, Zoltan Adam Tamus

    Low voltage cables play a crucial role in the safe and reliable operation of nuclear power plants. This paper discusses the effect of simultaneous combined thermal and mechanical stresses on the overall insulation of unshielded low voltage power cables used in nuclear power plants. Cable samples based on XLPE/CSPE insulation were exposed to thermal-mechanical combined accelerated aging tests for an extended period lasted to 907 hours. Time and frequency domain dielectric spectroscopy were applied to reveal the degradation level of the core insulation and jacket due to combined stresses. The former technique was conducted through the measurement of the decay and return voltage slopes, while the latter technique was based on the measurement of the complex permittivity. Moreover, the mechanical properties of the cable insulation were investigated by applying the measurement of the Shore D hardness. The results showed that the combined aging affects both the electrical and mechanical properties of the overall insulation. The complex permittivity at 100 Hz, the decay voltage slope, and the hardness had an upward trend with aging, while the return voltage slope showed an inverse trend. In addition, the results of the electrical and mechanical measurements showed strong correlation with aging time and further correlation was observed between the dielectric and mechanical properties. The correlation between aging time and test results suggests that the presented test methods are promising tools for in situ condition monitoring of low voltage unshielded cables in nuclear power plants.