Tobias Sankowsky-Rothe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tobias Sankowsky-Rothe has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Blau
Institut für Hörtechnik und Audiologie, Jade Hochschule, Ofener Str. 16, 26121 Oldenburg, Germany
4 shared publications Steven van de Par
Acoustics Group, Carl von Ossietzky Universität Oldenburg, Carl-von-Ossietzky-Str. 9-11, 26129 Oldenburg, Germany
2 shared publications- Henning Schepker
Signal Processing Group, Department of Medical Physics and Acoustics and the Cluster of Excellence "Hearing4All", University of Oldenburg, Oldenburg, Germany
1 shared publication Matthias Blau
Institut für Hörtechnik und Audiologie, Jade Hochschule, Ofener Str. 16/19, 26121 Oldenburg, Germany
1 shared publication- Simon Doclo
Carl von Ossietzky Universität Oldenburg
1 shared publication
Latest Publications
- Open Access
- 26 May 2023
- Published by EDP Sciences in Acta Acustica
- Vol. 7, 21
Parametric model of young infants’ eardrum and ear canal impedances supporting immittance measurement results. Part II: Prediction of eardrum and ear canal impedances for frequent pathological middle ear conditions
In order to gain a better understanding of wideband acoustic immitance (WAI) measurements, in this second part of a two-part paper, the parametric electro-acoustic model of the ear canal and the middle ear of young infants proposed in the first part is extended. The extension allows predictions of the influence of the pathological middle ear conditions middle ear effusion and negative static air pressure difference between the middle ear and the ear canal. Comparisons of the acoustic input impedance of the ear predicted by the model with real ear measurements in young infants’ ears with middle ear effusion show that the effects due to the pathology can be predicted well. For the negative static air pressure, a modeling approach was proposed but could not be confirmed yet, due to a lack of available measurement data. Furthermore, comparisons between different middle ear states (healthy, middle ear effusion and static air pressure difference) predicted by the model showed characteristic differences in all relevant WAI measures. However, it is also shown that WAI measures requiring an estimate of the cross-sectional area at the measurement position, i.e., absorbance and reflectance, are highly sensitive to this estimate.
- 26 May 2023
- Published by EDP Sciences in Acta Acustica
- Vol. 7, 21
Open AccessParametric model of young infants’ eardrum and ear canal impedances supporting immittance measurement results. Part II: Prediction of eardrum and ear canal impedances for frequent pathological middle ear conditions
In order to gain a better understanding of wideband acoustic immitance (WAI) measurements, in this second part of a two-part paper, the parametric electro-acoustic model of the ear canal and the middle ear of young infants proposed in the first part is extended. The extension allows predictions of the influence of the pathological middle ear conditions middle ear effusion and negative static air pressure difference between the middle ear and the ear canal. Comparisons of the acoustic input impedance of the ear predicted by the model with real ear measurements in young infants’ ears with middle ear effusion show that the effects due to the pathology can be predicted well. For the negative static air pressure, a modeling approach was proposed but could not be confirmed yet, due to a lack of available measurement data. Furthermore, comparisons between different middle ear states (healthy, middle ear effusion and static air pressure difference) predicted by the model showed characteristic differences in all relevant WAI measures. However, it is also shown that WAI measures requiring an estimate of the cross-sectional area at the measurement position, i.e., absorbance and reflectance, are highly sensitive to this estimate.
- Open Access
- 16 November 2022
- Published by EDP Sciences in Acta Acustica
- Vol. 6, 53
Parametric model of young infants’ eardrum and ear canal impedances supporting immittance measurement results. Part I: Development of the model
Wideband acoustic immitance (WAI) measurements provide an objective means to detect pathological middle ear conditions. However, for ears of young infants, it is still difficult to make clear statements about the middle ear status based on WAI measurements. In order to gain a better understanding of WAI data obtained in young infants’ ears, a parametric electro-acoustic model of the ear canal and the middle ear of young infants is proposed. In this first part of the two-part paper, the development of the model for the healthy ear is presented. Based on an existing model for adult ears, the presented model is adapted to young infants’ ears, uses parameters suited to represent physiological properties, and uses a smaller number of parameters in order to reduce model complexity. A comparison of the acoustic input impedance of the ear predicted by the model with real ear measurements in young infants’ ears showed a good agreement in the main characteristics. Model predictions show that the medium frequency range (about 1–3 kHz) of the acoustic input impedance of the ear is dominated by the properties of the eardrum and the middle ear, indicating that pathological middle ear conditions can preferably be detected in this frequency range.
- 16 November 2022
- Published by EDP Sciences in Acta Acustica
- Vol. 6, 53
Open AccessParametric model of young infants’ eardrum and ear canal impedances supporting immittance measurement results. Part I: Development of the model
Wideband acoustic immitance (WAI) measurements provide an objective means to detect pathological middle ear conditions. However, for ears of young infants, it is still difficult to make clear statements about the middle ear status based on WAI measurements. In order to gain a better understanding of WAI data obtained in young infants’ ears, a parametric electro-acoustic model of the ear canal and the middle ear of young infants is proposed. In this first part of the two-part paper, the development of the model for the healthy ear is presented. Based on an existing model for adult ears, the presented model is adapted to young infants’ ears, uses parameters suited to represent physiological properties, and uses a smaller number of parameters in order to reduce model complexity. A comparison of the acoustic input impedance of the ear predicted by the model with real ear measurements in young infants’ ears showed a good agreement in the main characteristics. Model predictions show that the medium frequency range (about 1–3 kHz) of the acoustic input impedance of the ear is dominated by the properties of the eardrum and the middle ear, indicating that pathological middle ear conditions can preferably be detected in this frequency range.
- 1 May 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 141 (5_Suppleme) , 3633
Measurements of the acoustic feedback path of hearing aids on human subjects
Feedback is a problem in hearing aids which will cause signal degradation and reduce the maximum applicable gain. More specifically, the advantages of open fittings (e.g., minimizing the occlusion effect) are limited by acoustic feedback. Feedback cancelation algorithms are used to overcome these limitations. For the development of such algorithms, the acoustic feedback path of the hearing aid must be known. The acoustic feedback path is not only affected by the outer sound field but by the individual anatomy and physiology as well. In order to quantify these different influences, feedback path measurements were performed on 20 human subjects. The measurements included different static conditions as well as dynamic ones (i.e., repetitive movements were performed during the measurement). Since the sound pressure level must be limited in measurements on human subjects, a valid identification of the feedback path is difficult in many cases, due to a low signal to noise ratio. Therefore, all measurements were performed reciprocally in addition to the direct measurements. Results show that yaw movements only have a small influence on the acoustic feedback path, whereas changes of the outer sound field can have a substantial impact on the feedback path.
- 1 May 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 141 (5_Suppleme) , 3633
Measurements of the acoustic feedback path of hearing aids on human subjects
Feedback is a problem in hearing aids which will cause signal degradation and reduce the maximum applicable gain. More specifically, the advantages of open fittings (e.g., minimizing the occlusion effect) are limited by acoustic feedback. Feedback cancelation algorithms are used to overcome these limitations. For the development of such algorithms, the acoustic feedback path of the hearing aid must be known. The acoustic feedback path is not only affected by the outer sound field but by the individual anatomy and physiology as well. In order to quantify these different influences, feedback path measurements were performed on 20 human subjects. The measurements included different static conditions as well as dynamic ones (i.e., repetitive movements were performed during the measurement). Since the sound pressure level must be limited in measurements on human subjects, a valid identification of the feedback path is difficult in many cases, due to a low signal to noise ratio. Therefore, all measurements were performed reciprocally in addition to the direct measurements. Results show that yaw movements only have a small influence on the acoustic feedback path, whereas changes of the outer sound field can have a substantial impact on the feedback path.
- 1 January 2017
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
Static and dynamic measurements of the acoustic feedback path of hearing aids on human subjects
Feedback is a problem in hearing aids which will cause signal degradation and reduce the maximum applicable gain. More specifically, the advantages of open fittings (e.g. minimizing the occlusion effect) are limited by acoustic feedback. Feedback cancellation algorithms are used to overcome these limitations. For the development of such algorithms, the acoustic feedback path of the hearing aid must be known. The acoustic feedback path is not only affected by the outer sound field but by the individual anatomy and physiology as well. In order to quantify these different influences, feedback path measurements were performed on 20 human subjects. The measurements included different static conditions as well as dynamic ones (i.e. repetitive movements were performed during the measurement). Since the sound pressure level must be limited in measurements on human subjects, a valid identification of the feedback path is difficult in many cases, due to a low signal to noise ratio. Therefore, all measurements were performed reciprocally in addition to the direct measurements. Results show that yaw movements only have a small influence on the acoustic feedback path, whereas changes of the outer sound field can have a substantial impact on the feedback path.
- 1 January 2017
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
Static and dynamic measurements of the acoustic feedback path of hearing aids on human subjects
Feedback is a problem in hearing aids which will cause signal degradation and reduce the maximum applicable gain. More specifically, the advantages of open fittings (e.g. minimizing the occlusion effect) are limited by acoustic feedback. Feedback cancellation algorithms are used to overcome these limitations. For the development of such algorithms, the acoustic feedback path of the hearing aid must be known. The acoustic feedback path is not only affected by the outer sound field but by the individual anatomy and physiology as well. In order to quantify these different influences, feedback path measurements were performed on 20 human subjects. The measurements included different static conditions as well as dynamic ones (i.e. repetitive movements were performed during the measurement). Since the sound pressure level must be limited in measurements on human subjects, a valid identification of the feedback path is difficult in many cases, due to a low signal to noise ratio. Therefore, all measurements were performed reciprocally in addition to the direct measurements. Results show that yaw movements only have a small influence on the acoustic feedback path, whereas changes of the outer sound field can have a substantial impact on the feedback path.
- 1 October 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 138 (4) , EL399-EL404
Reciprocal measurement of acoustic feedback paths in hearing aids
A reciprocal measurement procedure to measure the acoustic feedback path in hearing aids is investigated. The advantage of the reciprocal measurement compared to the direct measurement is a significantly reduced sound pressure in the ear. The direct and reciprocal measurements are compared using measurements on a dummy head with adjustable ear canals, different earmolds, and variations in the outer sound field. The results show that the reciprocal measurement procedure can be used to obtain plausible feedback paths, while reducing the sound pressure in the ear canal by 30 to 40 dB.
- 1 October 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 138 (4) , EL399-EL404
Reciprocal measurement of acoustic feedback paths in hearing aids
A reciprocal measurement procedure to measure the acoustic feedback path in hearing aids is investigated. The advantage of the reciprocal measurement compared to the direct measurement is a significantly reduced sound pressure in the ear. The direct and reciprocal measurements are compared using measurements on a dummy head with adjustable ear canals, different earmolds, and variations in the outer sound field. The results show that the reciprocal measurement procedure can be used to obtain plausible feedback paths, while reducing the sound pressure in the ear canal by 30 to 40 dB.